{"title":"用于生物发电的微生物燃料电池的性能评估:电位扫描速率和实时外部负载的影响","authors":"I. Meshack Simeon, A. Gbabo, R. Freitag","doi":"10.1007/s13762-024-05989-8","DOIUrl":null,"url":null,"abstract":"<p>The electrochemical performance of microbial fuel cells is conventionally assessed through linear sweep voltammetry at predefined potential scan rates. Nevertheless, this approach frequently falls short in representing the long-term behavior of microbial fuel cells under actual external loads, highlighting the need for a standardized evaluation method incorporating both linear sweep voltammetry and external loads. To address this gap, this study evaluates the performance of single-chamber microbial fuel cells under different loads and scan rates. The MFCs were tested with external loads of 1200, 470, and 270 Ω, derived from maximum power points of polarization sweeps at scan rates of 0.1, 0.5, and 1 mV/s at two operational phases. Power estimates at these scan rates were 61.96, 87.88, and 166.68 mW/m<sup>2</sup> at current densities of 116.5, 229.6, and 403 mA/m<sup>2</sup>, respectively. In the initial two hours, average power densities with 1200, 470, and 270 Ω were 73 ± 16.7, 36.3 ± 42, and 88.5 ± 120.1 mW/m<sup>2</sup>, respectively. Over the long term, the fuel cells under constant loading with resistance estimated at 0.1 mV/s showed average power 73.7% and 89.1% higher than those with resistances estimated at 0.5 mV/s and 1 mV/s, respectively, indicating that higher scan rates lead to overestimation of power. Although initially underestimated, the 0.1 mV/s scan rate more accurately reflected the true long-term performance of the fuel cells. This study emphasizes the importance of using appropriate scan rates for linear sweep voltammetry to obtain realistic long-term performance estimates of microbial fuel cells under real-time loads.</p>","PeriodicalId":589,"journal":{"name":"International Journal of Environmental Science and Technology","volume":"56 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of microbial fuel cells for bioelectricity generation: influence of potential scan-rate and real-time external load\",\"authors\":\"I. Meshack Simeon, A. Gbabo, R. Freitag\",\"doi\":\"10.1007/s13762-024-05989-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The electrochemical performance of microbial fuel cells is conventionally assessed through linear sweep voltammetry at predefined potential scan rates. Nevertheless, this approach frequently falls short in representing the long-term behavior of microbial fuel cells under actual external loads, highlighting the need for a standardized evaluation method incorporating both linear sweep voltammetry and external loads. To address this gap, this study evaluates the performance of single-chamber microbial fuel cells under different loads and scan rates. The MFCs were tested with external loads of 1200, 470, and 270 Ω, derived from maximum power points of polarization sweeps at scan rates of 0.1, 0.5, and 1 mV/s at two operational phases. Power estimates at these scan rates were 61.96, 87.88, and 166.68 mW/m<sup>2</sup> at current densities of 116.5, 229.6, and 403 mA/m<sup>2</sup>, respectively. In the initial two hours, average power densities with 1200, 470, and 270 Ω were 73 ± 16.7, 36.3 ± 42, and 88.5 ± 120.1 mW/m<sup>2</sup>, respectively. Over the long term, the fuel cells under constant loading with resistance estimated at 0.1 mV/s showed average power 73.7% and 89.1% higher than those with resistances estimated at 0.5 mV/s and 1 mV/s, respectively, indicating that higher scan rates lead to overestimation of power. Although initially underestimated, the 0.1 mV/s scan rate more accurately reflected the true long-term performance of the fuel cells. This study emphasizes the importance of using appropriate scan rates for linear sweep voltammetry to obtain realistic long-term performance estimates of microbial fuel cells under real-time loads.</p>\",\"PeriodicalId\":589,\"journal\":{\"name\":\"International Journal of Environmental Science and Technology\",\"volume\":\"56 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Environmental Science and Technology\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1007/s13762-024-05989-8\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Environmental Science and Technology","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1007/s13762-024-05989-8","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Performance evaluation of microbial fuel cells for bioelectricity generation: influence of potential scan-rate and real-time external load
The electrochemical performance of microbial fuel cells is conventionally assessed through linear sweep voltammetry at predefined potential scan rates. Nevertheless, this approach frequently falls short in representing the long-term behavior of microbial fuel cells under actual external loads, highlighting the need for a standardized evaluation method incorporating both linear sweep voltammetry and external loads. To address this gap, this study evaluates the performance of single-chamber microbial fuel cells under different loads and scan rates. The MFCs were tested with external loads of 1200, 470, and 270 Ω, derived from maximum power points of polarization sweeps at scan rates of 0.1, 0.5, and 1 mV/s at two operational phases. Power estimates at these scan rates were 61.96, 87.88, and 166.68 mW/m2 at current densities of 116.5, 229.6, and 403 mA/m2, respectively. In the initial two hours, average power densities with 1200, 470, and 270 Ω were 73 ± 16.7, 36.3 ± 42, and 88.5 ± 120.1 mW/m2, respectively. Over the long term, the fuel cells under constant loading with resistance estimated at 0.1 mV/s showed average power 73.7% and 89.1% higher than those with resistances estimated at 0.5 mV/s and 1 mV/s, respectively, indicating that higher scan rates lead to overestimation of power. Although initially underestimated, the 0.1 mV/s scan rate more accurately reflected the true long-term performance of the fuel cells. This study emphasizes the importance of using appropriate scan rates for linear sweep voltammetry to obtain realistic long-term performance estimates of microbial fuel cells under real-time loads.
期刊介绍:
International Journal of Environmental Science and Technology (IJEST) is an international scholarly refereed research journal which aims to promote the theory and practice of environmental science and technology, innovation, engineering and management.
A broad outline of the journal''s scope includes: peer reviewed original research articles, case and technical reports, reviews and analyses papers, short communications and notes to the editor, in interdisciplinary information on the practice and status of research in environmental science and technology, both natural and man made.
The main aspects of research areas include, but are not exclusive to; environmental chemistry and biology, environments pollution control and abatement technology, transport and fate of pollutants in the environment, concentrations and dispersion of wastes in air, water, and soil, point and non-point sources pollution, heavy metals and organic compounds in the environment, atmospheric pollutants and trace gases, solid and hazardous waste management; soil biodegradation and bioremediation of contaminated sites; environmental impact assessment, industrial ecology, ecological and human risk assessment; improved energy management and auditing efficiency and environmental standards and criteria.