评估基于 Carbothane™ 3575A 的电纺血管移植物在体外和体内的特性。

IF 3.9 3区 医学 Q2 ENGINEERING, BIOMEDICAL Biomedical materials Pub Date : 2024-09-10 DOI:10.1088/1748-605x/ad792d
Vera Sergeevna Chernonosova,Olesia Osipova,Zhou Nuankai,Inna Shundrina,Ivan S Murashov,Yurii Larichev,Andrey A Karpenko,Pavel P Laktionov
{"title":"评估基于 Carbothane™ 3575A 的电纺血管移植物在体外和体内的特性。","authors":"Vera Sergeevna Chernonosova,Olesia Osipova,Zhou Nuankai,Inna Shundrina,Ivan S Murashov,Yurii Larichev,Andrey A Karpenko,Pavel P Laktionov","doi":"10.1088/1748-605x/ad792d","DOIUrl":null,"url":null,"abstract":"Bioengineered vascular grafts have emerged as a promising alternative to the treatment of damaged or occlusive vessels. It is thought that polyurethane-based scaffolds possess suitable hemocompatibility and biomechanics comparable to those of normal blood vessels. In this study, we investigated the properties of electrospun scaffolds comprising various blends of biostable polycarbonate-based polyurethane (Carbothane™ 3575A) and gelatin. Scaffolds were characterized by scanning electron microscopy, infra-red spectroscopy, small-angle X-ray scattering, stress-loading tests, and interactions with primary human cells and blood. Data from in vitro experiments demonstrated that a scaffold produced from a blend of 5% Carbothane™ 3575A and 10% gelatin has proven to be a suitable material for fabricating a small-diameter vascular graft. A comparative in vivo study of such vascular grafts and ePTFE grafts implanted in the abdominal aorta of Wistar rats was performed. The data of intravital study and histological examination indicated that Carbothane-based electrospun grafts outclass ePTFE grafts and represent a promising device for preclinical studies to satisfy vascular surgery needs.","PeriodicalId":9016,"journal":{"name":"Biomedical materials","volume":null,"pages":null},"PeriodicalIF":3.9000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of properties for Carbothane™ 3575A-based electrospun vascular grafts in vitro and in vivo.\",\"authors\":\"Vera Sergeevna Chernonosova,Olesia Osipova,Zhou Nuankai,Inna Shundrina,Ivan S Murashov,Yurii Larichev,Andrey A Karpenko,Pavel P Laktionov\",\"doi\":\"10.1088/1748-605x/ad792d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bioengineered vascular grafts have emerged as a promising alternative to the treatment of damaged or occlusive vessels. It is thought that polyurethane-based scaffolds possess suitable hemocompatibility and biomechanics comparable to those of normal blood vessels. In this study, we investigated the properties of electrospun scaffolds comprising various blends of biostable polycarbonate-based polyurethane (Carbothane™ 3575A) and gelatin. Scaffolds were characterized by scanning electron microscopy, infra-red spectroscopy, small-angle X-ray scattering, stress-loading tests, and interactions with primary human cells and blood. Data from in vitro experiments demonstrated that a scaffold produced from a blend of 5% Carbothane™ 3575A and 10% gelatin has proven to be a suitable material for fabricating a small-diameter vascular graft. A comparative in vivo study of such vascular grafts and ePTFE grafts implanted in the abdominal aorta of Wistar rats was performed. The data of intravital study and histological examination indicated that Carbothane-based electrospun grafts outclass ePTFE grafts and represent a promising device for preclinical studies to satisfy vascular surgery needs.\",\"PeriodicalId\":9016,\"journal\":{\"name\":\"Biomedical materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1748-605x/ad792d\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1748-605x/ad792d","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

生物工程血管移植物已成为治疗受损或闭塞血管的一种有前途的替代方法。据认为,聚氨酯基支架具有适当的血液相容性和与正常血管相当的生物力学性能。在这项研究中,我们研究了电纺支架的特性,其中包括各种生物稳定性聚碳酸酯基聚氨酯(Carbothane™ 3575A)和明胶的混合物。通过扫描电子显微镜、红外光谱、小角 X 射线散射、应力加载测试以及与原代人体细胞和血液的相互作用对支架进行了表征。体外实验数据表明,由 5% Carbothane™ 3575A 和 10% 明胶混合制成的支架已被证明是制造小直径血管移植物的合适材料。对这种血管移植物和植入 Wistar 大鼠腹主动脉的 ePTFE 移植物进行了体内对比研究。体内观察研究和组织学检查数据表明,基于硫化卡硼烷的电纺移植物优于聚四氟乙烯移植物,是临床前研究满足血管外科需求的一种有前途的装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of properties for Carbothane™ 3575A-based electrospun vascular grafts in vitro and in vivo.
Bioengineered vascular grafts have emerged as a promising alternative to the treatment of damaged or occlusive vessels. It is thought that polyurethane-based scaffolds possess suitable hemocompatibility and biomechanics comparable to those of normal blood vessels. In this study, we investigated the properties of electrospun scaffolds comprising various blends of biostable polycarbonate-based polyurethane (Carbothane™ 3575A) and gelatin. Scaffolds were characterized by scanning electron microscopy, infra-red spectroscopy, small-angle X-ray scattering, stress-loading tests, and interactions with primary human cells and blood. Data from in vitro experiments demonstrated that a scaffold produced from a blend of 5% Carbothane™ 3575A and 10% gelatin has proven to be a suitable material for fabricating a small-diameter vascular graft. A comparative in vivo study of such vascular grafts and ePTFE grafts implanted in the abdominal aorta of Wistar rats was performed. The data of intravital study and histological examination indicated that Carbothane-based electrospun grafts outclass ePTFE grafts and represent a promising device for preclinical studies to satisfy vascular surgery needs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical materials
Biomedical materials 工程技术-材料科学:生物材料
CiteScore
6.70
自引率
7.50%
发文量
294
审稿时长
3 months
期刊介绍: The goal of the journal is to publish original research findings and critical reviews that contribute to our knowledge about the composition, properties, and performance of materials for all applications relevant to human healthcare. Typical areas of interest include (but are not limited to): -Synthesis/characterization of biomedical materials- Nature-inspired synthesis/biomineralization of biomedical materials- In vitro/in vivo performance of biomedical materials- Biofabrication technologies/applications: 3D bioprinting, bioink development, bioassembly & biopatterning- Microfluidic systems (including disease models): fabrication, testing & translational applications- Tissue engineering/regenerative medicine- Interaction of molecules/cells with materials- Effects of biomaterials on stem cell behaviour- Growth factors/genes/cells incorporated into biomedical materials- Biophysical cues/biocompatibility pathways in biomedical materials performance- Clinical applications of biomedical materials for cell therapies in disease (cancer etc)- Nanomedicine, nanotoxicology and nanopathology- Pharmacokinetic considerations in drug delivery systems- Risks of contrast media in imaging systems- Biosafety aspects of gene delivery agents- Preclinical and clinical performance of implantable biomedical materials- Translational and regulatory matters
期刊最新文献
A low-swelling alginate hydrogel with antibacterial hemostatic and radical scavenging properties for open wound healing. Evaluation of properties for Carbothane™ 3575A-based electrospun vascular grafts in vitro and in vivo. Migration and retention of human osteosarcoma cells in bioceramic graft with open channel architecture designed for bone tissue engineering. Enhancement of induction heating capability of bioactive SiO2–CaO–Na2O–P2O5 glass-ceramics by selective substitution with magnetite nanoparticles A xenogeneic extracellular matrix-based 3D printing scaffold modified by ceria nanoparticles for craniomaxillofacial hard tissue regeneration via osteo-immunomodulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1