精确测定光束望远镜的轨道位置分辨率

M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth
{"title":"精确测定光束望远镜的轨道位置分辨率","authors":"M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth","doi":"arxiv-2408.17215","DOIUrl":null,"url":null,"abstract":"Beam tests using tracking telescopes are a standard method for determining\nthe spatial resolution of detectors. This requires the precise knowledge of the\nposition resolution of beam tracks reconstructed at the Device Under Test\n(DUT). A method is proposed which achieves this using a segmented silicon\ndetector with readout with charge digitization. It is found that the DUT\nspatial resolution for particles with normal incidence is less than 1 $\\mu$m\nfor events where clusters consist of two pixels (or strips). Given this\naccuracy, the residual of the beam track-position at the DUT and the position\nreconstructed in the DUT provides the beam track-position resolution\ndistribution. The method is developed using simulated events, which are also\nused to study how to deal with cross-talk, electronics noise, energetic $\\delta\n$-electrons, and incident beams with a few degrees off the normal to the sensor\nplane. To validate the method, the position resolution of beam tracks\nreconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is\ndetermined using a CMS Phase-2 prototype pixel sensor.","PeriodicalId":501374,"journal":{"name":"arXiv - PHYS - Instrumentation and Detectors","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision determination of the track-position resolution of beam telescopes\",\"authors\":\"M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth\",\"doi\":\"arxiv-2408.17215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Beam tests using tracking telescopes are a standard method for determining\\nthe spatial resolution of detectors. This requires the precise knowledge of the\\nposition resolution of beam tracks reconstructed at the Device Under Test\\n(DUT). A method is proposed which achieves this using a segmented silicon\\ndetector with readout with charge digitization. It is found that the DUT\\nspatial resolution for particles with normal incidence is less than 1 $\\\\mu$m\\nfor events where clusters consist of two pixels (or strips). Given this\\naccuracy, the residual of the beam track-position at the DUT and the position\\nreconstructed in the DUT provides the beam track-position resolution\\ndistribution. The method is developed using simulated events, which are also\\nused to study how to deal with cross-talk, electronics noise, energetic $\\\\delta\\n$-electrons, and incident beams with a few degrees off the normal to the sensor\\nplane. To validate the method, the position resolution of beam tracks\\nreconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is\\ndetermined using a CMS Phase-2 prototype pixel sensor.\",\"PeriodicalId\":501374,\"journal\":{\"name\":\"arXiv - PHYS - Instrumentation and Detectors\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Instrumentation and Detectors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2408.17215\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.17215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用跟踪望远镜进行光束测试是确定探测器空间分辨率的标准方法。这需要精确了解在被测设备(DUT)上重建的光束轨迹的位置分辨率。本文提出了一种方法,利用带电荷数字化读出的分段硅探测器来实现这一目标。研究发现,对于由两个像素(或条带)组成的簇的事件,正常入射粒子的 DUT 空间分辨率小于 1 $\mu$m。考虑到这一精度,DUT 上光束轨迹位置的残差和在 DUT 中重建的位置提供了光束轨迹位置分辨率分布。该方法是利用模拟事件开发的,模拟事件也用于研究如何处理串扰、电子噪声、高能电子和偏离传感器平面法线几度的入射光束。为了验证该方法,使用 CMS 第二阶段原型像素传感器确定了由 DESY II 试验光束设施的 EUDET 光束望远镜构建的光束轨迹的位置分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Precision determination of the track-position resolution of beam telescopes
Beam tests using tracking telescopes are a standard method for determining the spatial resolution of detectors. This requires the precise knowledge of the position resolution of beam tracks reconstructed at the Device Under Test (DUT). A method is proposed which achieves this using a segmented silicon detector with readout with charge digitization. It is found that the DUT spatial resolution for particles with normal incidence is less than 1 $\mu$m for events where clusters consist of two pixels (or strips). Given this accuracy, the residual of the beam track-position at the DUT and the position reconstructed in the DUT provides the beam track-position resolution distribution. The method is developed using simulated events, which are also used to study how to deal with cross-talk, electronics noise, energetic $\delta $-electrons, and incident beams with a few degrees off the normal to the sensor plane. To validate the method, the position resolution of beam tracks reconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is determined using a CMS Phase-2 prototype pixel sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy Ultraviolet cross-luminescence in ternary chlorides of alkali and alkaline-earth metals Performance Evaluation of an RFSoC Operating in a 1.25 Tesla Magnetic Field Numerical Studies of Straw Tube Detectors Advanced Halide Scintillators: From the Bulk to Nano
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1