M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth
{"title":"精确测定光束望远镜的轨道位置分辨率","authors":"M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth","doi":"arxiv-2408.17215","DOIUrl":null,"url":null,"abstract":"Beam tests using tracking telescopes are a standard method for determining\nthe spatial resolution of detectors. This requires the precise knowledge of the\nposition resolution of beam tracks reconstructed at the Device Under Test\n(DUT). A method is proposed which achieves this using a segmented silicon\ndetector with readout with charge digitization. It is found that the DUT\nspatial resolution for particles with normal incidence is less than 1 $\\mu$m\nfor events where clusters consist of two pixels (or strips). Given this\naccuracy, the residual of the beam track-position at the DUT and the position\nreconstructed in the DUT provides the beam track-position resolution\ndistribution. The method is developed using simulated events, which are also\nused to study how to deal with cross-talk, electronics noise, energetic $\\delta\n$-electrons, and incident beams with a few degrees off the normal to the sensor\nplane. To validate the method, the position resolution of beam tracks\nreconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is\ndetermined using a CMS Phase-2 prototype pixel sensor.","PeriodicalId":501374,"journal":{"name":"arXiv - PHYS - Instrumentation and Detectors","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision determination of the track-position resolution of beam telescopes\",\"authors\":\"M. Antonello, L. Eikelmann, E. Garutti, R. Klanner, J. Schwandt, G. Steinbrück, A. Vauth\",\"doi\":\"arxiv-2408.17215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Beam tests using tracking telescopes are a standard method for determining\\nthe spatial resolution of detectors. This requires the precise knowledge of the\\nposition resolution of beam tracks reconstructed at the Device Under Test\\n(DUT). A method is proposed which achieves this using a segmented silicon\\ndetector with readout with charge digitization. It is found that the DUT\\nspatial resolution for particles with normal incidence is less than 1 $\\\\mu$m\\nfor events where clusters consist of two pixels (or strips). Given this\\naccuracy, the residual of the beam track-position at the DUT and the position\\nreconstructed in the DUT provides the beam track-position resolution\\ndistribution. The method is developed using simulated events, which are also\\nused to study how to deal with cross-talk, electronics noise, energetic $\\\\delta\\n$-electrons, and incident beams with a few degrees off the normal to the sensor\\nplane. To validate the method, the position resolution of beam tracks\\nreconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is\\ndetermined using a CMS Phase-2 prototype pixel sensor.\",\"PeriodicalId\":501374,\"journal\":{\"name\":\"arXiv - PHYS - Instrumentation and Detectors\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Instrumentation and Detectors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2408.17215\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.17215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Precision determination of the track-position resolution of beam telescopes
Beam tests using tracking telescopes are a standard method for determining
the spatial resolution of detectors. This requires the precise knowledge of the
position resolution of beam tracks reconstructed at the Device Under Test
(DUT). A method is proposed which achieves this using a segmented silicon
detector with readout with charge digitization. It is found that the DUT
spatial resolution for particles with normal incidence is less than 1 $\mu$m
for events where clusters consist of two pixels (or strips). Given this
accuracy, the residual of the beam track-position at the DUT and the position
reconstructed in the DUT provides the beam track-position resolution
distribution. The method is developed using simulated events, which are also
used to study how to deal with cross-talk, electronics noise, energetic $\delta
$-electrons, and incident beams with a few degrees off the normal to the sensor
plane. To validate the method, the position resolution of beam tracks
reconstructed by the EUDET beam telescope of the DESY II Test Beam Facility is
determined using a CMS Phase-2 prototype pixel sensor.