{"title":"利用区域供热系统的灵活性促进配电系统的运行:基于集合的特征描述和时间分解","authors":"Weitao Chen;Xiaojun Wang;Wei Wei;Yin Xu;Jianzhong Wu","doi":"10.1109/TSTE.2024.3452560","DOIUrl":null,"url":null,"abstract":"The proliferation of distributed renewable resources increases the uncertainty in distribution systems. Coupling the distribution system and district heating system helps leverage the flexibility of thermal storage and thus supports the operation of the electrical grid. This paper proposes a method to characterize flexibility from district heating system via polyhedral sets. First, a recursive robust feasibility condition that ensures heat supply adequacy under uncertain demand is established. Then, stagewise robust feasible sets of thermal storage levels are calculated using a customized projection algorithm. Finally, dynamic bounds of electric heaters are computed by a further projection step. With those dynamic bounds, the electric heaters behave like reducible loads, and the demands in each period are decoupled over time, although the dispatch of thermal storage units must comply with inter-temporal constraints. The proposed method allows the two coupled systems to be operated in a distributed way without forecasts and extensive communications. Numerical simulations on small and practically sized testing systems validate the advantage of the proposed method. On average, the set calculation takes about 8 minutes for the day-ahead problem and 11 seconds for real-time dispatch on a portable laptop, and the prediction-free operation policy has an average optimality gap of 3.6% compared to the hindsight optimum.","PeriodicalId":452,"journal":{"name":"IEEE Transactions on Sustainable Energy","volume":"16 1","pages":"227-241"},"PeriodicalIF":8.6000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploiting the Flexibility of District Heating System for Distribution System Operation: Set-Based Characterization and Temporal Decomposition\",\"authors\":\"Weitao Chen;Xiaojun Wang;Wei Wei;Yin Xu;Jianzhong Wu\",\"doi\":\"10.1109/TSTE.2024.3452560\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The proliferation of distributed renewable resources increases the uncertainty in distribution systems. Coupling the distribution system and district heating system helps leverage the flexibility of thermal storage and thus supports the operation of the electrical grid. This paper proposes a method to characterize flexibility from district heating system via polyhedral sets. First, a recursive robust feasibility condition that ensures heat supply adequacy under uncertain demand is established. Then, stagewise robust feasible sets of thermal storage levels are calculated using a customized projection algorithm. Finally, dynamic bounds of electric heaters are computed by a further projection step. With those dynamic bounds, the electric heaters behave like reducible loads, and the demands in each period are decoupled over time, although the dispatch of thermal storage units must comply with inter-temporal constraints. The proposed method allows the two coupled systems to be operated in a distributed way without forecasts and extensive communications. Numerical simulations on small and practically sized testing systems validate the advantage of the proposed method. On average, the set calculation takes about 8 minutes for the day-ahead problem and 11 seconds for real-time dispatch on a portable laptop, and the prediction-free operation policy has an average optimality gap of 3.6% compared to the hindsight optimum.\",\"PeriodicalId\":452,\"journal\":{\"name\":\"IEEE Transactions on Sustainable Energy\",\"volume\":\"16 1\",\"pages\":\"227-241\"},\"PeriodicalIF\":8.6000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Sustainable Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10660566/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Sustainable Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10660566/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Exploiting the Flexibility of District Heating System for Distribution System Operation: Set-Based Characterization and Temporal Decomposition
The proliferation of distributed renewable resources increases the uncertainty in distribution systems. Coupling the distribution system and district heating system helps leverage the flexibility of thermal storage and thus supports the operation of the electrical grid. This paper proposes a method to characterize flexibility from district heating system via polyhedral sets. First, a recursive robust feasibility condition that ensures heat supply adequacy under uncertain demand is established. Then, stagewise robust feasible sets of thermal storage levels are calculated using a customized projection algorithm. Finally, dynamic bounds of electric heaters are computed by a further projection step. With those dynamic bounds, the electric heaters behave like reducible loads, and the demands in each period are decoupled over time, although the dispatch of thermal storage units must comply with inter-temporal constraints. The proposed method allows the two coupled systems to be operated in a distributed way without forecasts and extensive communications. Numerical simulations on small and practically sized testing systems validate the advantage of the proposed method. On average, the set calculation takes about 8 minutes for the day-ahead problem and 11 seconds for real-time dispatch on a portable laptop, and the prediction-free operation policy has an average optimality gap of 3.6% compared to the hindsight optimum.
期刊介绍:
The IEEE Transactions on Sustainable Energy serves as a pivotal platform for sharing groundbreaking research findings on sustainable energy systems, with a focus on their seamless integration into power transmission and/or distribution grids. The journal showcases original research spanning the design, implementation, grid-integration, and control of sustainable energy technologies and systems. Additionally, the Transactions warmly welcomes manuscripts addressing the design, implementation, and evaluation of power systems influenced by sustainable energy systems and devices.