利用环境电离串联质谱法快速检测面罩上摄入的对乙酰氨基酚

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL Analytica Chimica Acta Pub Date : 2024-09-12 DOI:10.1016/j.aca.2024.343225
{"title":"利用环境电离串联质谱法快速检测面罩上摄入的对乙酰氨基酚","authors":"","doi":"10.1016/j.aca.2024.343225","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>A regular face mask is comprised of three layers for resisting moisture, filtration, and absorbing oral fluid, respectively. Since the polymers with different polarities are used to make the layers, a face mask can be used as a sampling tool to retain polar or non-polar chemical and biochemical substances in the exhaled breath. In this study, thermal desorption-electrospray ionization tandem mass spectrometry (TD-ESI/MS/MS), an ambient ionization mass spectrometric technique, was used to detect trace acetaminophen that were exhaled and retained on the surface of different layers in a face mask.</p></div><div><h3>Results</h3><p>With probe sampling combined with TD-ESI/MS/MS, the acetaminophen ion signal can be detected at the mouth/nostril region of the face mask after taking the acetaminophen tablet. The experimental results were similar to previous studies for the detection of acetaminophen in blood over time using LC/MS/MS. In addition, the intensities of acetaminophen on different layers of the face mask could reveal the differing distributions of exhaled acetaminophen on each layer. To explore the distribution of acetaminophen on the face mask surface, multiple probes were used to collect samples from different locations of the face mask for analysis. The molecular mapping of acetaminophen on the face mask was rendered by scaling the analyte ion signal intensity based on a temperature color gradient. The cartography showed a higher acetaminophen ion signal distribution on the mouth and nostril regions than in other areas of the face mask.</p></div><div><h3>Significance</h3><p>Owing to the advantages of a simple, sensitive, and non-invasive sampling approach, drug monitoring could be potentially performed to provide useful information for anti-drug of precision medicine in the future.</p></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid detection of ingested acetaminophen on face mask by ambient ionization tandem mass spectrometry\",\"authors\":\"\",\"doi\":\"10.1016/j.aca.2024.343225\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>A regular face mask is comprised of three layers for resisting moisture, filtration, and absorbing oral fluid, respectively. Since the polymers with different polarities are used to make the layers, a face mask can be used as a sampling tool to retain polar or non-polar chemical and biochemical substances in the exhaled breath. In this study, thermal desorption-electrospray ionization tandem mass spectrometry (TD-ESI/MS/MS), an ambient ionization mass spectrometric technique, was used to detect trace acetaminophen that were exhaled and retained on the surface of different layers in a face mask.</p></div><div><h3>Results</h3><p>With probe sampling combined with TD-ESI/MS/MS, the acetaminophen ion signal can be detected at the mouth/nostril region of the face mask after taking the acetaminophen tablet. The experimental results were similar to previous studies for the detection of acetaminophen in blood over time using LC/MS/MS. In addition, the intensities of acetaminophen on different layers of the face mask could reveal the differing distributions of exhaled acetaminophen on each layer. To explore the distribution of acetaminophen on the face mask surface, multiple probes were used to collect samples from different locations of the face mask for analysis. The molecular mapping of acetaminophen on the face mask was rendered by scaling the analyte ion signal intensity based on a temperature color gradient. The cartography showed a higher acetaminophen ion signal distribution on the mouth and nostril regions than in other areas of the face mask.</p></div><div><h3>Significance</h3><p>Owing to the advantages of a simple, sensitive, and non-invasive sampling approach, drug monitoring could be potentially performed to provide useful information for anti-drug of precision medicine in the future.</p></div>\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003267024010262\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267024010262","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景普通口罩由三层组成,分别用于防潮、过滤和吸收口腔液体。由于口罩层是由不同极性的聚合物制成的,因此口罩可作为一种采样工具来保留呼出气体中的极性或非极性化学和生化物质。本研究采用热脱附-电喷雾离子化串联质谱(TD-ESI/MS/MS)这一环境离子化质谱技术来检测呼出的痕量对乙酰氨基酚,并将其保留在口罩中不同层的表面上。结果通过探针采样与 TD-ESI/MS/MS 的结合,可以在服用对乙酰氨基酚片剂后在口罩的口腔/鼻翼区域检测到对乙酰氨基酚离子信号。实验结果与之前使用 LC/MS/MS 检测血液中对乙酰氨基酚浓度的研究结果相似。此外,对乙酰氨基酚在面罩不同层上的强度可以揭示呼出的对乙酰氨基酚在各层上的不同分布。为了探索对乙酰氨基酚在面罩表面的分布情况,使用了多个探针从面罩的不同位置采集样本进行分析。根据温度颜色梯度缩放分析物离子信号强度,绘制出对乙酰氨基酚在面罩上的分子分布图。结果表明,口腔和鼻孔区域的对乙酰氨基酚离子信号分布高于面罩的其他区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rapid detection of ingested acetaminophen on face mask by ambient ionization tandem mass spectrometry

Background

A regular face mask is comprised of three layers for resisting moisture, filtration, and absorbing oral fluid, respectively. Since the polymers with different polarities are used to make the layers, a face mask can be used as a sampling tool to retain polar or non-polar chemical and biochemical substances in the exhaled breath. In this study, thermal desorption-electrospray ionization tandem mass spectrometry (TD-ESI/MS/MS), an ambient ionization mass spectrometric technique, was used to detect trace acetaminophen that were exhaled and retained on the surface of different layers in a face mask.

Results

With probe sampling combined with TD-ESI/MS/MS, the acetaminophen ion signal can be detected at the mouth/nostril region of the face mask after taking the acetaminophen tablet. The experimental results were similar to previous studies for the detection of acetaminophen in blood over time using LC/MS/MS. In addition, the intensities of acetaminophen on different layers of the face mask could reveal the differing distributions of exhaled acetaminophen on each layer. To explore the distribution of acetaminophen on the face mask surface, multiple probes were used to collect samples from different locations of the face mask for analysis. The molecular mapping of acetaminophen on the face mask was rendered by scaling the analyte ion signal intensity based on a temperature color gradient. The cartography showed a higher acetaminophen ion signal distribution on the mouth and nostril regions than in other areas of the face mask.

Significance

Owing to the advantages of a simple, sensitive, and non-invasive sampling approach, drug monitoring could be potentially performed to provide useful information for anti-drug of precision medicine in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
期刊最新文献
LC-MS simultaneous profiling of acyl-CoA and acyl-carnitine in dynamic metabolic status Photoelectron-transfer-effect grafting: Validation of a generalized strategy for fluorescence and photoelectrochemical dual-mode detection of hydrogen sulfide Rapid detection of ingested acetaminophen on face mask by ambient ionization tandem mass spectrometry Fluorogenic target competitors for developing label-free and sensitive folding-unswitching aptamer sensors Isolation and quantification of human urinary exosomes using a Tween-20 elution solvent from polyester, capillary-channeled polymer fiber columns
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1