{"title":"用于护理点血小板功能分析的集成式微流控多电极聚集测定法","authors":"X. Zhao, V. R. Gopal, F. Lozano-Juan, K. Kolandaivelu, A. Sarkar, D. Wu, J. Su, Q. Cheng, R. Pang and L.-S. Wu","doi":"10.1039/D4LC00469H","DOIUrl":null,"url":null,"abstract":"<p >Point-of-care (POC) platelet function analysis can enable timely and precise management of bleeding and clotting in emergency rooms, operation rooms and intensive care units. However, POC platelet testing is currently not commonly performed, due to the complexity of sample preparation and limitations of existing technologies. Here, we report the development of an integrated microfluidic multiple electrode aggregometry (μMEA) sensor which uses multi-frequency impedance measurement of an embedded microelectrode array to perform platelet aggregometry directly from whole blood, sensing and measuring platelet activation in a label-free manner and without requiring any additional sample preparation. Additionally, the sensor incorporates blood flow during the assay to account for physiological flow and shear conditions. We show that the impedance signal from the sensor can be used to accurately detect and quantify platelet aggregation in a label-free manner, which was further validated by simultaneous fluorometric measurement and visualization of platelet aggregation. Further, we optimized the sensitivity and repeatability of the sensor using its frequency response and demonstrated that the sensor could be used to characterize drug dose–response in antiplatelet therapy with a frequency-tunable dynamic range. We also demonstrate that the sensor provides high sensitivity to perform platelet aggregometry under thrombocytopenic or low platelet count conditions. The μMEA sensor could thus enable POC platelet function analysis across several clinical applications.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":null,"pages":null},"PeriodicalIF":6.1000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Integrated microfluidic multiple electrode aggregometry for point-of-care platelet function analysis†\",\"authors\":\"X. Zhao, V. R. Gopal, F. Lozano-Juan, K. Kolandaivelu, A. Sarkar, D. Wu, J. Su, Q. Cheng, R. Pang and L.-S. Wu\",\"doi\":\"10.1039/D4LC00469H\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Point-of-care (POC) platelet function analysis can enable timely and precise management of bleeding and clotting in emergency rooms, operation rooms and intensive care units. However, POC platelet testing is currently not commonly performed, due to the complexity of sample preparation and limitations of existing technologies. Here, we report the development of an integrated microfluidic multiple electrode aggregometry (μMEA) sensor which uses multi-frequency impedance measurement of an embedded microelectrode array to perform platelet aggregometry directly from whole blood, sensing and measuring platelet activation in a label-free manner and without requiring any additional sample preparation. Additionally, the sensor incorporates blood flow during the assay to account for physiological flow and shear conditions. We show that the impedance signal from the sensor can be used to accurately detect and quantify platelet aggregation in a label-free manner, which was further validated by simultaneous fluorometric measurement and visualization of platelet aggregation. Further, we optimized the sensitivity and repeatability of the sensor using its frequency response and demonstrated that the sensor could be used to characterize drug dose–response in antiplatelet therapy with a frequency-tunable dynamic range. We also demonstrate that the sensor provides high sensitivity to perform platelet aggregometry under thrombocytopenic or low platelet count conditions. The μMEA sensor could thus enable POC platelet function analysis across several clinical applications.</p>\",\"PeriodicalId\":85,\"journal\":{\"name\":\"Lab on a Chip\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lab on a Chip\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00469h\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00469h","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

在急诊室、手术室和重症监护室,护理点(POC)血小板功能分析可对出血和凝血进行及时、精确的管理。然而,由于样本制备的复杂性和现有技术的局限性,POC 血小板检测目前并不普遍。在此,我们报告了一种集成微流控多电极聚集测量(μMEA)传感器的开发情况,该传感器利用嵌入式微电极阵列的多频阻抗测量,直接从全血中进行血小板聚集测量,以无标记的方式感应和测量血小板活化,无需额外的样品制备。此外,该传感器还结合了检测过程中的血流情况,以考虑生理流动和剪切条件。我们的研究表明,传感器发出的阻抗信号可用于以无标记方式准确检测和量化血小板聚集,而同时对血小板聚集进行荧光测量和可视化则进一步验证了这一点。此外,我们还利用其频率响应优化了传感器的灵敏度和可重复性,并证明该传感器可用于表征抗血小板治疗中的药物剂量反应,其动态范围可根据频率进行调整。我们还证明,该传感器在血小板减少或血小板计数低的条件下进行血小板聚集测定时具有高灵敏度。因此,μMEA 传感器可在多个临床应用中实现 POC 血小板功能分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Integrated microfluidic multiple electrode aggregometry for point-of-care platelet function analysis†

Point-of-care (POC) platelet function analysis can enable timely and precise management of bleeding and clotting in emergency rooms, operation rooms and intensive care units. However, POC platelet testing is currently not commonly performed, due to the complexity of sample preparation and limitations of existing technologies. Here, we report the development of an integrated microfluidic multiple electrode aggregometry (μMEA) sensor which uses multi-frequency impedance measurement of an embedded microelectrode array to perform platelet aggregometry directly from whole blood, sensing and measuring platelet activation in a label-free manner and without requiring any additional sample preparation. Additionally, the sensor incorporates blood flow during the assay to account for physiological flow and shear conditions. We show that the impedance signal from the sensor can be used to accurately detect and quantify platelet aggregation in a label-free manner, which was further validated by simultaneous fluorometric measurement and visualization of platelet aggregation. Further, we optimized the sensitivity and repeatability of the sensor using its frequency response and demonstrated that the sensor could be used to characterize drug dose–response in antiplatelet therapy with a frequency-tunable dynamic range. We also demonstrate that the sensor provides high sensitivity to perform platelet aggregometry under thrombocytopenic or low platelet count conditions. The μMEA sensor could thus enable POC platelet function analysis across several clinical applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Observing root growth and signalling responses to stress gradients and pathogens using the bi-directional dual-flow RootChip Optical tweezer-assisted cell pairing and fusion for somatic cell nuclear transfer within an open microchannel. Microstring-engineered tension tissues: A novel platform for replicating tissue mechanics and advancing mechanobiology Discretised microfluidics for noninvasive health monitoring using sweat sensing Inside back cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1