Ragaa El Sheikh , Ayman A. Gouda , Ahmed A. Ghazy , Nesma M. Jumaa , Noha E.M. Elsaify , Nehal S.A. Soliman , Asmaa El Sayed , Ahmed H. Moustafa , Ahmad O. Babalghith , Ahmed El Sayed , Al-Sayed M.Abd El-Majeed
{"title":"开发和验证用于估算纯品和剂型中心律失常药物-盐酸决奈达隆的分光光度法","authors":"Ragaa El Sheikh , Ayman A. Gouda , Ahmed A. Ghazy , Nesma M. Jumaa , Noha E.M. Elsaify , Nehal S.A. Soliman , Asmaa El Sayed , Ahmed H. Moustafa , Ahmad O. Babalghith , Ahmed El Sayed , Al-Sayed M.Abd El-Majeed","doi":"10.1016/j.talo.2024.100355","DOIUrl":null,"url":null,"abstract":"<div><p>Sensitive, simple, and accurate spectrophotometric methods have been developed for the assay of arrhythmias drug-dronedarone hydrochloride (DND) in bulk drug and pharmaceutical formulations. The proposed method is based on the oxidation reaction of DND with a known excess of cerium(IV) ammonium sulfate (Ce(IV)) as an oxidizing agent in acid medium, followed by the determination of the unreacted oxidant by adding a fixed amount of dye, e.g., amaranth (AM), methylene blue (MB), and indigocarmine (IC), followed by measuring the absorbance at 520, 664, and 610 nm, respectively. The effects of experimental conditions were studied and optimized. The beer's law was obeyed in the concentration ranges of 1.0–10, 1.0–15, and 1.0–8.0 μg mL<sup>-1</sup> using AM, MB, and IC dyes, respectively, with a correlation coefficient ≥ 0.9992. The calculated molar absorptivity values are 3.6527 × 10<sup>4</sup>, 3.1212 × 10<sup>4</sup>, and 4.229 × 10<sup>4</sup> L mol<sup>-1</sup> cm<sup>-1</sup> using AM, MB, and IC dyes, respectively. The limits of detection and quantification were 0.30 and 1.0 µg mL<sup>-1</sup>, respectively, for the three methods. Intra-day and inter-day accuracy and precision of the methods have been evaluated. No interference was observed from the additives. The proposed methods were successfully applied to the assay of DND in tablet preparations and the results were statistically compared with those of the reported method by applying Student's <em>t</em>-test and F-test. The reliability of the methods was further ascertained by performing recovery studies using the standard addition method.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"10 ","pages":"Article 100355"},"PeriodicalIF":4.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666831924000699/pdfft?md5=f8ecd77d8a8d7d158b1cb91bf04e548c&pid=1-s2.0-S2666831924000699-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Development and validation of spectrophotometric methods for estimation of arrhythmias drug-dronedarone hydrochloride in pure and dosage forms\",\"authors\":\"Ragaa El Sheikh , Ayman A. Gouda , Ahmed A. Ghazy , Nesma M. Jumaa , Noha E.M. Elsaify , Nehal S.A. Soliman , Asmaa El Sayed , Ahmed H. Moustafa , Ahmad O. Babalghith , Ahmed El Sayed , Al-Sayed M.Abd El-Majeed\",\"doi\":\"10.1016/j.talo.2024.100355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Sensitive, simple, and accurate spectrophotometric methods have been developed for the assay of arrhythmias drug-dronedarone hydrochloride (DND) in bulk drug and pharmaceutical formulations. The proposed method is based on the oxidation reaction of DND with a known excess of cerium(IV) ammonium sulfate (Ce(IV)) as an oxidizing agent in acid medium, followed by the determination of the unreacted oxidant by adding a fixed amount of dye, e.g., amaranth (AM), methylene blue (MB), and indigocarmine (IC), followed by measuring the absorbance at 520, 664, and 610 nm, respectively. The effects of experimental conditions were studied and optimized. The beer's law was obeyed in the concentration ranges of 1.0–10, 1.0–15, and 1.0–8.0 μg mL<sup>-1</sup> using AM, MB, and IC dyes, respectively, with a correlation coefficient ≥ 0.9992. The calculated molar absorptivity values are 3.6527 × 10<sup>4</sup>, 3.1212 × 10<sup>4</sup>, and 4.229 × 10<sup>4</sup> L mol<sup>-1</sup> cm<sup>-1</sup> using AM, MB, and IC dyes, respectively. The limits of detection and quantification were 0.30 and 1.0 µg mL<sup>-1</sup>, respectively, for the three methods. Intra-day and inter-day accuracy and precision of the methods have been evaluated. No interference was observed from the additives. The proposed methods were successfully applied to the assay of DND in tablet preparations and the results were statistically compared with those of the reported method by applying Student's <em>t</em>-test and F-test. The reliability of the methods was further ascertained by performing recovery studies using the standard addition method.</p></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":\"10 \",\"pages\":\"Article 100355\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666831924000699/pdfft?md5=f8ecd77d8a8d7d158b1cb91bf04e548c&pid=1-s2.0-S2666831924000699-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831924000699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924000699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
本研究开发了灵敏、简单、准确的分光光度法,用于检测散装药物和药物制剂中的心律失常药物-盐酸决奈达隆(DND)。所提出的方法是以已知过量的硫酸铵铈(Ce(IV))为氧化剂,在酸性介质中对 DND 进行氧化反应,然后加入一定量的染料(如苋菜红(AM)、亚甲基蓝(MB)和靛红(IC)),分别在 520、664 和 610 纳米波长处测量吸光度,以测定未反应的氧化剂。对实验条件的影响进行了研究和优化。在 AM、MB 和 IC 染料的浓度范围分别为 1.0-10、1.0-15 和 1.0-8.0 μg mL-1 时,均符合啤酒定律,相关系数≥ 0.9992。使用 AM、MB 和 IC 染料计算的摩尔吸收率值分别为 3.6527 × 104、3.1212 × 104 和 4.229 × 104 L mol-1 cm-1。三种方法的检测和定量限分别为 0.30 和 1.0 µg mL-1。对方法的日内和日间准确度和精密度进行了评估。没有发现添加剂的干扰。建议的方法成功地应用于片剂中 DND 的检测,并通过学生 t 检验和 F 检验将结果与报告的方法进行了统计比较。通过使用标准添加法进行回收率研究,进一步确定了方法的可靠性。
Development and validation of spectrophotometric methods for estimation of arrhythmias drug-dronedarone hydrochloride in pure and dosage forms
Sensitive, simple, and accurate spectrophotometric methods have been developed for the assay of arrhythmias drug-dronedarone hydrochloride (DND) in bulk drug and pharmaceutical formulations. The proposed method is based on the oxidation reaction of DND with a known excess of cerium(IV) ammonium sulfate (Ce(IV)) as an oxidizing agent in acid medium, followed by the determination of the unreacted oxidant by adding a fixed amount of dye, e.g., amaranth (AM), methylene blue (MB), and indigocarmine (IC), followed by measuring the absorbance at 520, 664, and 610 nm, respectively. The effects of experimental conditions were studied and optimized. The beer's law was obeyed in the concentration ranges of 1.0–10, 1.0–15, and 1.0–8.0 μg mL-1 using AM, MB, and IC dyes, respectively, with a correlation coefficient ≥ 0.9992. The calculated molar absorptivity values are 3.6527 × 104, 3.1212 × 104, and 4.229 × 104 L mol-1 cm-1 using AM, MB, and IC dyes, respectively. The limits of detection and quantification were 0.30 and 1.0 µg mL-1, respectively, for the three methods. Intra-day and inter-day accuracy and precision of the methods have been evaluated. No interference was observed from the additives. The proposed methods were successfully applied to the assay of DND in tablet preparations and the results were statistically compared with those of the reported method by applying Student's t-test and F-test. The reliability of the methods was further ascertained by performing recovery studies using the standard addition method.