利用 3.3 μm 波长的干涉免疫微分吸收光谱法同时测量碳氢化合物火焰中的温度和 C2H4 浓度

IF 3.1 3区 物理与天体物理 Q2 INSTRUMENTS & INSTRUMENTATION Infrared Physics & Technology Pub Date : 2024-09-15 DOI:10.1016/j.infrared.2024.105556
Wenjian Huang, Guangzhen Gao, Mingke Zhang, Shujing Ruan, Tingdong Cai
{"title":"利用 3.3 μm 波长的干涉免疫微分吸收光谱法同时测量碳氢化合物火焰中的温度和 C2H4 浓度","authors":"Wenjian Huang,&nbsp;Guangzhen Gao,&nbsp;Mingke Zhang,&nbsp;Shujing Ruan,&nbsp;Tingdong Cai","doi":"10.1016/j.infrared.2024.105556","DOIUrl":null,"url":null,"abstract":"<div><p>In diagnostic applications based on tunable diode laser absorption spectroscopy, the measurement of target substances can be influenced by factors such as background thermal radiation in the combustion environment, extinction caused by solid or liquid particles, and other interfering absorptions. In this work, we developed a differential absorption diagnostic technique based on wavelength pairs, utilizing an interband cascade laser near 3.3 μm to simultaneously measure temperature and C<sub>2</sub>H<sub>4</sub> concentration in hydrocarbon flames. Based on a detailed study of the C<sub>2</sub>H<sub>4</sub> spectrum in this region and considering the optimal standard for spectral lines, two wavelength pairs were selected. The temperature is determined by the ratio of the absorption cross-sections of two wavelength pairs, and the C<sub>2</sub>H<sub>4</sub> concentration is inferred based on the wavelength pair with higher differential absorption. In the initial stage, the system’s accuracy was verified in high-temperature static conditions (<em>T</em> = 300–800 K, <em>P</em> = 1 atm), and continuous time series measurements demonstrated the system’s stability. The limit of detection achieved by Allan-Werle variance analysis is 2.5 ppm at the optimal average time of 100 s. Subsequently, measurements were taken in a hydrocarbon flame. The obtained results indicate an average deviation of 1.021 % between the measured temperature in the flame and the reference value, with a standard deviation of 1.381 % for concentration measurement. All the measurements show that the system can be potentially applied to combustion diagnosis.</p></div>","PeriodicalId":13549,"journal":{"name":"Infrared Physics & Technology","volume":"142 ","pages":"Article 105556"},"PeriodicalIF":3.1000,"publicationDate":"2024-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous measurement of temperature and C2H4 concentration in hydrocarbon flames using interference-immune differential absorption spectroscopy at 3.3 μm\",\"authors\":\"Wenjian Huang,&nbsp;Guangzhen Gao,&nbsp;Mingke Zhang,&nbsp;Shujing Ruan,&nbsp;Tingdong Cai\",\"doi\":\"10.1016/j.infrared.2024.105556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In diagnostic applications based on tunable diode laser absorption spectroscopy, the measurement of target substances can be influenced by factors such as background thermal radiation in the combustion environment, extinction caused by solid or liquid particles, and other interfering absorptions. In this work, we developed a differential absorption diagnostic technique based on wavelength pairs, utilizing an interband cascade laser near 3.3 μm to simultaneously measure temperature and C<sub>2</sub>H<sub>4</sub> concentration in hydrocarbon flames. Based on a detailed study of the C<sub>2</sub>H<sub>4</sub> spectrum in this region and considering the optimal standard for spectral lines, two wavelength pairs were selected. The temperature is determined by the ratio of the absorption cross-sections of two wavelength pairs, and the C<sub>2</sub>H<sub>4</sub> concentration is inferred based on the wavelength pair with higher differential absorption. In the initial stage, the system’s accuracy was verified in high-temperature static conditions (<em>T</em> = 300–800 K, <em>P</em> = 1 atm), and continuous time series measurements demonstrated the system’s stability. The limit of detection achieved by Allan-Werle variance analysis is 2.5 ppm at the optimal average time of 100 s. Subsequently, measurements were taken in a hydrocarbon flame. The obtained results indicate an average deviation of 1.021 % between the measured temperature in the flame and the reference value, with a standard deviation of 1.381 % for concentration measurement. All the measurements show that the system can be potentially applied to combustion diagnosis.</p></div>\",\"PeriodicalId\":13549,\"journal\":{\"name\":\"Infrared Physics & Technology\",\"volume\":\"142 \",\"pages\":\"Article 105556\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infrared Physics & Technology\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350449524004407\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infrared Physics & Technology","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350449524004407","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

在基于可调谐二极管激光吸收光谱的诊断应用中,目标物质的测量可能会受到燃烧环境中背景热辐射、固体或液体颗粒引起的消光以及其他干扰吸收等因素的影响。在这项工作中,我们开发了一种基于波长对的差分吸收诊断技术,利用 3.3 μm 附近的带间级联激光同时测量碳氢化合物火焰中的温度和 C2H4 浓度。根据对该区域 C2H4 光谱的详细研究,并考虑到光谱线的最佳标准,选择了两个波长对。温度由两个波长对的吸收截面之比确定,C2H4 浓度则根据吸收差值较大的波长对推断。在初始阶段,该系统的准确性在高温静态条件下(T = 300-800 K,P = 1 atm)得到了验证,连续的时间序列测量证明了该系统的稳定性。通过 Allan-Werle 方差分析,在最佳平均时间 100 秒时的检测限为 2.5 ppm。测量结果表明,火焰中的测量温度与参考值之间的平均偏差为 1.021%,浓度测量的标准偏差为 1.381%。所有测量结果表明,该系统可用于燃烧诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous measurement of temperature and C2H4 concentration in hydrocarbon flames using interference-immune differential absorption spectroscopy at 3.3 μm

In diagnostic applications based on tunable diode laser absorption spectroscopy, the measurement of target substances can be influenced by factors such as background thermal radiation in the combustion environment, extinction caused by solid or liquid particles, and other interfering absorptions. In this work, we developed a differential absorption diagnostic technique based on wavelength pairs, utilizing an interband cascade laser near 3.3 μm to simultaneously measure temperature and C2H4 concentration in hydrocarbon flames. Based on a detailed study of the C2H4 spectrum in this region and considering the optimal standard for spectral lines, two wavelength pairs were selected. The temperature is determined by the ratio of the absorption cross-sections of two wavelength pairs, and the C2H4 concentration is inferred based on the wavelength pair with higher differential absorption. In the initial stage, the system’s accuracy was verified in high-temperature static conditions (T = 300–800 K, P = 1 atm), and continuous time series measurements demonstrated the system’s stability. The limit of detection achieved by Allan-Werle variance analysis is 2.5 ppm at the optimal average time of 100 s. Subsequently, measurements were taken in a hydrocarbon flame. The obtained results indicate an average deviation of 1.021 % between the measured temperature in the flame and the reference value, with a standard deviation of 1.381 % for concentration measurement. All the measurements show that the system can be potentially applied to combustion diagnosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.70
自引率
12.10%
发文量
400
审稿时长
67 days
期刊介绍: The Journal covers the entire field of infrared physics and technology: theory, experiment, application, devices and instrumentation. Infrared'' is defined as covering the near, mid and far infrared (terahertz) regions from 0.75um (750nm) to 1mm (300GHz.) Submissions in the 300GHz to 100GHz region may be accepted at the editors discretion if their content is relevant to shorter wavelengths. Submissions must be primarily concerned with and directly relevant to this spectral region. Its core topics can be summarized as the generation, propagation and detection, of infrared radiation; the associated optics, materials and devices; and its use in all fields of science, industry, engineering and medicine. Infrared techniques occur in many different fields, notably spectroscopy and interferometry; material characterization and processing; atmospheric physics, astronomy and space research. Scientific aspects include lasers, quantum optics, quantum electronics, image processing and semiconductor physics. Some important applications are medical diagnostics and treatment, industrial inspection and environmental monitoring.
期刊最新文献
Breaking dimensional barriers in hyperspectral target detection: Atrous convolution with Gramian Angular field representations Multi-Scale convolutional neural network for finger vein recognition Temporal denoising and deep feature learning for enhanced defect detection in thermography using stacked denoising convolution autoencoder Detection of black tea fermentation quality based on optimized deep neural network and hyperspectral imaging Hyperspectral and multispectral images fusion based on pyramid swin transformer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1