使用智能手机的人工智能系统与人体测量结果之间的髋臼杯置入角度相关性

IF 1.5 Q3 ORTHOPEDICS Arthroplasty Today Pub Date : 2024-09-18 DOI:10.1016/j.artd.2024.101439
Sachiyuki Tsukada MD, PhD, Hiroyuki Ogawa MD, Masayoshi Saito MD, Naoyuki Hirasawa MD, PhD
{"title":"使用智能手机的人工智能系统与人体测量结果之间的髋臼杯置入角度相关性","authors":"Sachiyuki Tsukada MD, PhD,&nbsp;Hiroyuki Ogawa MD,&nbsp;Masayoshi Saito MD,&nbsp;Naoyuki Hirasawa MD, PhD","doi":"10.1016/j.artd.2024.101439","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>An automated measurement system for the placement angles of acetabular cup in total hip arthroplasty prostheses was developed utilizing artificial intelligence (AI) algorithms. The AI-powered system enables immediate measurement by capturing an anteroposterior pelvic X-ray through a smartphone camera.</p></div><div><h3>Methods</h3><p>While developing the AI-powered measurement system, we trained AI utilizing 100 labeled anteroposterior pelvic X-rays to recognize the hip joint and 483 labeled anteroposterior pelvic X-rays to identify anatomical landmarks and the acetabular cup. To validate the AI-powered system, we measured the acetabular cup placement angles of 126 unlabeled post-total hip arthroplasty anteroposterior pelvic X-rays with both the AI-powered system and conventional measurement methods and assessed the correlation between the 2 methods.</p></div><div><h3>Results</h3><p>The Pearson’s correlation coefficients for the acetabular cup placement angles measured using the AI-powered system and conventional method were 0.88 (95% confidence interval, 0.84-0.92, <em>P</em> &lt; .001) in inclination angle and 0.76 (95% confidence interval, 0.67-0.83, <em>P</em> &lt; .001) in anteversion angle, respectively.</p></div><div><h3>Conclusions</h3><p>Both inclination and anteversion angles measured using the AI-powered system showed a strong correlation with angles obtained through conventional methods.</p></div>","PeriodicalId":37940,"journal":{"name":"Arthroplasty Today","volume":"29 ","pages":"Article 101439"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352344124001249/pdfft?md5=aa9bd2aaa336f35d5d5799a6bab5ab99&pid=1-s2.0-S2352344124001249-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Correlation of Acetabular Cup Placement Angles Between an Artificial Intelligence-Powered System Using a Smartphone and Human Measurements\",\"authors\":\"Sachiyuki Tsukada MD, PhD,&nbsp;Hiroyuki Ogawa MD,&nbsp;Masayoshi Saito MD,&nbsp;Naoyuki Hirasawa MD, PhD\",\"doi\":\"10.1016/j.artd.2024.101439\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>An automated measurement system for the placement angles of acetabular cup in total hip arthroplasty prostheses was developed utilizing artificial intelligence (AI) algorithms. The AI-powered system enables immediate measurement by capturing an anteroposterior pelvic X-ray through a smartphone camera.</p></div><div><h3>Methods</h3><p>While developing the AI-powered measurement system, we trained AI utilizing 100 labeled anteroposterior pelvic X-rays to recognize the hip joint and 483 labeled anteroposterior pelvic X-rays to identify anatomical landmarks and the acetabular cup. To validate the AI-powered system, we measured the acetabular cup placement angles of 126 unlabeled post-total hip arthroplasty anteroposterior pelvic X-rays with both the AI-powered system and conventional measurement methods and assessed the correlation between the 2 methods.</p></div><div><h3>Results</h3><p>The Pearson’s correlation coefficients for the acetabular cup placement angles measured using the AI-powered system and conventional method were 0.88 (95% confidence interval, 0.84-0.92, <em>P</em> &lt; .001) in inclination angle and 0.76 (95% confidence interval, 0.67-0.83, <em>P</em> &lt; .001) in anteversion angle, respectively.</p></div><div><h3>Conclusions</h3><p>Both inclination and anteversion angles measured using the AI-powered system showed a strong correlation with angles obtained through conventional methods.</p></div>\",\"PeriodicalId\":37940,\"journal\":{\"name\":\"Arthroplasty Today\",\"volume\":\"29 \",\"pages\":\"Article 101439\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352344124001249/pdfft?md5=aa9bd2aaa336f35d5d5799a6bab5ab99&pid=1-s2.0-S2352344124001249-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty Today\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352344124001249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty Today","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352344124001249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景利用人工智能(AI)算法开发了一套全髋关节置换术假体髋臼杯置入角度自动测量系统。在开发人工智能测量系统的过程中,我们利用 100 张标记的骨盆前方 X 光片识别髋关节,并利用 483 张标记的骨盆前方 X 光片识别解剖地标和髋臼杯,对人工智能进行了训练。为了验证 AI 动力系统,我们使用 AI 动力系统和传统测量方法测量了 126 张未标记的全髋关节置换术后骨盆前方 X 光片的髋臼杯置入角,并评估了这两种方法之间的相关性。结果使用 AI 动力系统和传统方法测量的髋臼杯置入角的皮尔逊相关系数为 0.88 (95% confidence interval, 0.84-0.92, P <.001),内翻角的相关系数为 0.76 (95% confidence interval, 0.67-0.83, P <.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Correlation of Acetabular Cup Placement Angles Between an Artificial Intelligence-Powered System Using a Smartphone and Human Measurements

Background

An automated measurement system for the placement angles of acetabular cup in total hip arthroplasty prostheses was developed utilizing artificial intelligence (AI) algorithms. The AI-powered system enables immediate measurement by capturing an anteroposterior pelvic X-ray through a smartphone camera.

Methods

While developing the AI-powered measurement system, we trained AI utilizing 100 labeled anteroposterior pelvic X-rays to recognize the hip joint and 483 labeled anteroposterior pelvic X-rays to identify anatomical landmarks and the acetabular cup. To validate the AI-powered system, we measured the acetabular cup placement angles of 126 unlabeled post-total hip arthroplasty anteroposterior pelvic X-rays with both the AI-powered system and conventional measurement methods and assessed the correlation between the 2 methods.

Results

The Pearson’s correlation coefficients for the acetabular cup placement angles measured using the AI-powered system and conventional method were 0.88 (95% confidence interval, 0.84-0.92, P < .001) in inclination angle and 0.76 (95% confidence interval, 0.67-0.83, P < .001) in anteversion angle, respectively.

Conclusions

Both inclination and anteversion angles measured using the AI-powered system showed a strong correlation with angles obtained through conventional methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arthroplasty Today
Arthroplasty Today Medicine-Surgery
CiteScore
2.90
自引率
0.00%
发文量
258
审稿时长
40 weeks
期刊介绍: Arthroplasty Today is a companion journal to the Journal of Arthroplasty. The journal Arthroplasty Today brings together the clinical and scientific foundations for joint replacement of the hip and knee in an open-access, online format. Arthroplasty Today solicits manuscripts of the highest quality from all areas of scientific endeavor that relate to joint replacement or the treatment of its complications, including those dealing with patient outcomes, economic and policy issues, prosthetic design, biomechanics, biomaterials, and biologic response to arthroplasty. The journal focuses on case reports. It is the purpose of Arthroplasty Today to present material to practicing orthopaedic surgeons that will keep them abreast of developments in the field, prove useful in the care of patients, and aid in understanding the scientific foundation of this subspecialty area of joint replacement. The international members of the Editorial Board provide a worldwide perspective for the journal''s area of interest. Their participation ensures that each issue of Arthroplasty Today provides the reader with timely, peer-reviewed articles of the highest quality.
期刊最新文献
Early Results of a Patient-Specific Total Knee Arthroplasty Implant Cast From a 3D-Printed Mold Evaluation of a Mobile App to Assist Patient Education and Research in Arthroplasty Vancomycin Is Not an Effective Prophylactic Agent Alone and Should Be Combined With Another Agent Are Activity Restrictions Necessary After Total Hip Arthroplasty: A Systematic Review Operatively Managed Transverse or Short Oblique B1 Periprosthetic Fractures Around a Polished Taper-Slip Femoral Stem Are Associated With Reoperation in One Third of Cases: A Retrospective Cohort Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1