Andrea Matteucci, Carlo Pignalberi, Stefania Di Fusco, Alessandro Aiello, Stefano Aquilani, Federico Nardi, Furio Colivicchi
{"title":"通过多参数评估合理使用可穿戴除颤器,避免不必要的除颤器植入","authors":"Andrea Matteucci, Carlo Pignalberi, Stefania Di Fusco, Alessandro Aiello, Stefano Aquilani, Federico Nardi, Furio Colivicchi","doi":"10.1136/openhrt-2024-002787","DOIUrl":null,"url":null,"abstract":"Introduction Wearable cardioverter-defibrillators (WCD) have emerged as a valuable tool in the management of patients at risk for life-threatening arrhythmias. These devices offer a non-invasive and temporary solution, providing continuous monitoring and the potential for prompt defibrillation when needed. In this study, we explore the use of WCD and evaluate arrhythmic events through comprehensive monitoring. Methods From November 2022 to May 2024, we conducted an outpatient follow-up of 41 patients receiving WCD. Regular check-ups, remote monitoring and comprehensive echocardiography were performed to optimise a tailored therapy. Results The average age of the patients was 59.2.4±16.5 years, with 78% being male. Among the cohort, 54% had hypertension, 41% were smokers and 66% had dyslipidaemia, while 27% were diabetic. WCD was assigned according to the Italian Association of Hospital Cardiologists position paper focussing on the appropriate use of WCD and European Society of Cardiology guidelines on ventricular arrhythmias and the prevention of sudden cardiac death: 24 (58%) patients had a de novo diagnosis of heart failure with reduced ejection fraction, 11 (27%) patients had a recent acute coronary syndrome and ejection fraction <35%, 3 (7%) patients had a cardiac electronic device extraction and 3 (7%) patients had myocarditis with features of electrical instability. The average follow-up was 62±38 days according to specific aetiology, with a daily wearing time of 22.7±1.3 hours. No device interventions were recorded. At the end of the follow-up period, 15 patients still required an implantable cardioverter-defibrillator (ICD). Among these, 12 patients (29%) underwent ICD implantation. Two patients (5%) declined the procedure. Conclusions The use of WCD for patients at high risk of arrhythmias allowed to optimise therapy and limit the indications for ICD. Inappropriate implantation of ICD was avoided in 69% of patients who received WCD. The device showed a good safety profile, low incidence of device interventions and adequate patients’ adherence to WCD use. Data are available upon reasonable request.","PeriodicalId":19505,"journal":{"name":"Open Heart","volume":"13 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Appropriate use of wearable defibrillators with multiparametric evaluation to avoid unnecessary defibrillator implantation\",\"authors\":\"Andrea Matteucci, Carlo Pignalberi, Stefania Di Fusco, Alessandro Aiello, Stefano Aquilani, Federico Nardi, Furio Colivicchi\",\"doi\":\"10.1136/openhrt-2024-002787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction Wearable cardioverter-defibrillators (WCD) have emerged as a valuable tool in the management of patients at risk for life-threatening arrhythmias. These devices offer a non-invasive and temporary solution, providing continuous monitoring and the potential for prompt defibrillation when needed. In this study, we explore the use of WCD and evaluate arrhythmic events through comprehensive monitoring. Methods From November 2022 to May 2024, we conducted an outpatient follow-up of 41 patients receiving WCD. Regular check-ups, remote monitoring and comprehensive echocardiography were performed to optimise a tailored therapy. Results The average age of the patients was 59.2.4±16.5 years, with 78% being male. Among the cohort, 54% had hypertension, 41% were smokers and 66% had dyslipidaemia, while 27% were diabetic. WCD was assigned according to the Italian Association of Hospital Cardiologists position paper focussing on the appropriate use of WCD and European Society of Cardiology guidelines on ventricular arrhythmias and the prevention of sudden cardiac death: 24 (58%) patients had a de novo diagnosis of heart failure with reduced ejection fraction, 11 (27%) patients had a recent acute coronary syndrome and ejection fraction <35%, 3 (7%) patients had a cardiac electronic device extraction and 3 (7%) patients had myocarditis with features of electrical instability. The average follow-up was 62±38 days according to specific aetiology, with a daily wearing time of 22.7±1.3 hours. No device interventions were recorded. At the end of the follow-up period, 15 patients still required an implantable cardioverter-defibrillator (ICD). Among these, 12 patients (29%) underwent ICD implantation. Two patients (5%) declined the procedure. Conclusions The use of WCD for patients at high risk of arrhythmias allowed to optimise therapy and limit the indications for ICD. Inappropriate implantation of ICD was avoided in 69% of patients who received WCD. The device showed a good safety profile, low incidence of device interventions and adequate patients’ adherence to WCD use. Data are available upon reasonable request.\",\"PeriodicalId\":19505,\"journal\":{\"name\":\"Open Heart\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Heart\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/openhrt-2024-002787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Heart","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/openhrt-2024-002787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Appropriate use of wearable defibrillators with multiparametric evaluation to avoid unnecessary defibrillator implantation
Introduction Wearable cardioverter-defibrillators (WCD) have emerged as a valuable tool in the management of patients at risk for life-threatening arrhythmias. These devices offer a non-invasive and temporary solution, providing continuous monitoring and the potential for prompt defibrillation when needed. In this study, we explore the use of WCD and evaluate arrhythmic events through comprehensive monitoring. Methods From November 2022 to May 2024, we conducted an outpatient follow-up of 41 patients receiving WCD. Regular check-ups, remote monitoring and comprehensive echocardiography were performed to optimise a tailored therapy. Results The average age of the patients was 59.2.4±16.5 years, with 78% being male. Among the cohort, 54% had hypertension, 41% were smokers and 66% had dyslipidaemia, while 27% were diabetic. WCD was assigned according to the Italian Association of Hospital Cardiologists position paper focussing on the appropriate use of WCD and European Society of Cardiology guidelines on ventricular arrhythmias and the prevention of sudden cardiac death: 24 (58%) patients had a de novo diagnosis of heart failure with reduced ejection fraction, 11 (27%) patients had a recent acute coronary syndrome and ejection fraction <35%, 3 (7%) patients had a cardiac electronic device extraction and 3 (7%) patients had myocarditis with features of electrical instability. The average follow-up was 62±38 days according to specific aetiology, with a daily wearing time of 22.7±1.3 hours. No device interventions were recorded. At the end of the follow-up period, 15 patients still required an implantable cardioverter-defibrillator (ICD). Among these, 12 patients (29%) underwent ICD implantation. Two patients (5%) declined the procedure. Conclusions The use of WCD for patients at high risk of arrhythmias allowed to optimise therapy and limit the indications for ICD. Inappropriate implantation of ICD was avoided in 69% of patients who received WCD. The device showed a good safety profile, low incidence of device interventions and adequate patients’ adherence to WCD use. Data are available upon reasonable request.
期刊介绍:
Open Heart is an online-only, open access cardiology journal that aims to be “open” in many ways: open access (free access for all readers), open peer review (unblinded peer review) and open data (data sharing is encouraged). The goal is to ensure maximum transparency and maximum impact on research progress and patient care. The journal is dedicated to publishing high quality, peer reviewed medical research in all disciplines and therapeutic areas of cardiovascular medicine. Research is published across all study phases and designs, from study protocols to phase I trials to meta-analyses, including small or specialist studies. Opinionated discussions on controversial topics are welcomed. Open Heart aims to operate a fast submission and review process with continuous publication online, to ensure timely, up-to-date research is available worldwide. The journal adheres to a rigorous and transparent peer review process, and all articles go through a statistical assessment to ensure robustness of the analyses. Open Heart is an official journal of the British Cardiovascular Society.