IF 10.7 1区 生物学 Q1 BIOPHYSICS Biosensors and Bioelectronics Pub Date : 2024-09-17 DOI:10.1016/j.bios.2024.116792
{"title":"用于分离和检测无脂蛋白污染的细胞外囊泡的高分辨率螺旋微流控通道集成电化学装置","authors":"","doi":"10.1016/j.bios.2024.116792","DOIUrl":null,"url":null,"abstract":"<div><p>Recent studies have indicated significant correlation between the concentration of immune checkpoint markers borne by extracellular vesicles (EVs) and the efficacy of immunotherapy. This study introduces a high-resolution spiral microfluidic channel-integrated electrochemical device (HiMEc), which is designed to isolate and detect EVs carrying the immune checkpoint markers programmed death ligand 1 (PD-L1) and programmed death protein 1 (PD-1), devoid of plasma-abundant lipoprotein contamination. Antigen-antibody reactions were applied to immobilize the lipoproteins on bead surfaces within the plasma, establishing a size differential with EVs. A plasma sample was then introduced into the spiral microfluidic channel, which facilitated the acquisition of nanometer-sized EVs and the elimination of micrometer-sized lipoprotein-bead complexes, along with the isolation and quantification of EVs using HiMEc. PD-L1 and PD-1 expression on EVs was evaluated in 30 plasma samples (10 from healthy donors, 20 from lung cancer patients) using HiMEc and compared to the results obtained from standard tissue-based PD-L1 testing, noting that HiMEc could be utilized to select further potential candidates. The obtained results are expected to contribute positively to the clinical assessment of potential immunotherapy beneficiaries.</p></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":null,"pages":null},"PeriodicalIF":10.7000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-resolution spiral microfluidic channel integrated electrochemical device for isolation and detection of extracellular vesicles without lipoprotein contamination\",\"authors\":\"\",\"doi\":\"10.1016/j.bios.2024.116792\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Recent studies have indicated significant correlation between the concentration of immune checkpoint markers borne by extracellular vesicles (EVs) and the efficacy of immunotherapy. This study introduces a high-resolution spiral microfluidic channel-integrated electrochemical device (HiMEc), which is designed to isolate and detect EVs carrying the immune checkpoint markers programmed death ligand 1 (PD-L1) and programmed death protein 1 (PD-1), devoid of plasma-abundant lipoprotein contamination. Antigen-antibody reactions were applied to immobilize the lipoproteins on bead surfaces within the plasma, establishing a size differential with EVs. A plasma sample was then introduced into the spiral microfluidic channel, which facilitated the acquisition of nanometer-sized EVs and the elimination of micrometer-sized lipoprotein-bead complexes, along with the isolation and quantification of EVs using HiMEc. PD-L1 and PD-1 expression on EVs was evaluated in 30 plasma samples (10 from healthy donors, 20 from lung cancer patients) using HiMEc and compared to the results obtained from standard tissue-based PD-L1 testing, noting that HiMEc could be utilized to select further potential candidates. The obtained results are expected to contribute positively to the clinical assessment of potential immunotherapy beneficiaries.</p></div>\",\"PeriodicalId\":259,\"journal\":{\"name\":\"Biosensors and Bioelectronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":10.7000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S095656632400798X\",\"RegionNum\":1,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S095656632400798X","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

最近的研究表明,细胞外囊泡(EVs)携带的免疫检查点标记物的浓度与免疫疗法的疗效之间存在明显的相关性。本研究介绍了一种高分辨率螺旋微流控通道集成电化学装置(HiMEc),该装置旨在分离和检测携带免疫检查点标记物程序性死亡配体1(PD-L1)和程序性死亡蛋白1(PD-1)的EV,同时避免血浆中丰富的脂蛋白污染。应用抗原-抗体反应将脂蛋白固定在血浆中的珠子表面上,与EV建立大小差。然后将血浆样本导入螺旋微流控通道,这样就能获得纳米级大小的EV,消除微米级大小的脂蛋白-微珠复合物,并利用HiMEc对EV进行分离和定量。利用 HiMEc 评估了 30 份血浆样本(10 份来自健康捐献者,20 份来自肺癌患者)中 EVs 上的 PD-L1 和 PD-1 表达情况,并将其与基于组织的标准 PD-L1 检测结果进行了比较,结果表明 HiMEc 可用于筛选更多潜在候选者。所获得的结果有望为潜在免疫疗法受益者的临床评估做出积极贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-resolution spiral microfluidic channel integrated electrochemical device for isolation and detection of extracellular vesicles without lipoprotein contamination

Recent studies have indicated significant correlation between the concentration of immune checkpoint markers borne by extracellular vesicles (EVs) and the efficacy of immunotherapy. This study introduces a high-resolution spiral microfluidic channel-integrated electrochemical device (HiMEc), which is designed to isolate and detect EVs carrying the immune checkpoint markers programmed death ligand 1 (PD-L1) and programmed death protein 1 (PD-1), devoid of plasma-abundant lipoprotein contamination. Antigen-antibody reactions were applied to immobilize the lipoproteins on bead surfaces within the plasma, establishing a size differential with EVs. A plasma sample was then introduced into the spiral microfluidic channel, which facilitated the acquisition of nanometer-sized EVs and the elimination of micrometer-sized lipoprotein-bead complexes, along with the isolation and quantification of EVs using HiMEc. PD-L1 and PD-1 expression on EVs was evaluated in 30 plasma samples (10 from healthy donors, 20 from lung cancer patients) using HiMEc and compared to the results obtained from standard tissue-based PD-L1 testing, noting that HiMEc could be utilized to select further potential candidates. The obtained results are expected to contribute positively to the clinical assessment of potential immunotherapy beneficiaries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
期刊最新文献
Cortical, striatal, and thalamic populations self-organize into a functionally connected circuit with long-term memory properties NanoMIP beacons with a co-operative binding mechanism for the all-in-one detection of methamphetamine aptamer complexes Cascade enzyme-mimicking with spatially separated gold-ceria for dual-mode detection of superoxide anions One-step copper deposition-induced signal amplification for multiplex bacterial infection diagnosis on a lateral flow immunoassay device Novel cobalt-based aerogels for uric acid detection in fluids at physiological pH
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1