{"title":"多电平逆变器中的模型预测控制 第一部分:基本策略和性能改进","authors":"Cristian Garcia;Andres Mora;Margarita Norambuena;Jose Rodriguez;Mokhtar Aly;Fernanda Carnielutti;Javier Pereda;Pablo Acuna;Ricardo Aguilera;Luca Tarisciotti","doi":"10.1109/OJIA.2024.3460669","DOIUrl":null,"url":null,"abstract":"Multilevel inverters (MLIs) have lately become important due to their extended application to electrical transmission and distribution systems. At the same time, the control and modulation of MLIs are especially challenging due to the high number of switching states, many of them redundant in terms of output voltage generation, and their nonlinear characteristics. In order to ease their implementation in real environment, model predictive control (MPC) is often considered, where the main control targets are: 1) to generate a the desired output current and 2) to keep the internal converter capacitor voltages at their reference value. However, a major issue with the implementation of MPC in MLIs is that the number of calculations to be done online increases dramatically with the number of levels, making it almost impossible to apply MPC in some practical cases. For these reasons, one of the main research trend in MPC for MLIs is to provide an algorithm which can reduce the computational burden necessary to operate the control. The article proposes a review of such control techniques. Starting from the basic MPC implementation and using a flying capacitor converter as an example the article review the basic strategies to avoid calculating the weighting factor in the cost function, simplifying the implementation. Also, methods to reduce the number of calculations necessary to implement MPC are shown and applied to cascaded H-bridge converters. These techniques allow to keep an high load current quality while reducing more than 95% in the number of calculations necessary to implement the control. Finally, other operation improvements of MPC are also included, such as fixed switching frequency operation and multistep MPC, reaching an important performance improvement compared to the basic MPC strategy.","PeriodicalId":100629,"journal":{"name":"IEEE Open Journal of Industry Applications","volume":"5 ","pages":"428-441"},"PeriodicalIF":7.9000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10679905","citationCount":"0","resultStr":"{\"title\":\"Model Predictive Control in Multilevel Inverters Part I: Basic Strategy and Performance Improvement\",\"authors\":\"Cristian Garcia;Andres Mora;Margarita Norambuena;Jose Rodriguez;Mokhtar Aly;Fernanda Carnielutti;Javier Pereda;Pablo Acuna;Ricardo Aguilera;Luca Tarisciotti\",\"doi\":\"10.1109/OJIA.2024.3460669\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multilevel inverters (MLIs) have lately become important due to their extended application to electrical transmission and distribution systems. At the same time, the control and modulation of MLIs are especially challenging due to the high number of switching states, many of them redundant in terms of output voltage generation, and their nonlinear characteristics. In order to ease their implementation in real environment, model predictive control (MPC) is often considered, where the main control targets are: 1) to generate a the desired output current and 2) to keep the internal converter capacitor voltages at their reference value. However, a major issue with the implementation of MPC in MLIs is that the number of calculations to be done online increases dramatically with the number of levels, making it almost impossible to apply MPC in some practical cases. For these reasons, one of the main research trend in MPC for MLIs is to provide an algorithm which can reduce the computational burden necessary to operate the control. The article proposes a review of such control techniques. Starting from the basic MPC implementation and using a flying capacitor converter as an example the article review the basic strategies to avoid calculating the weighting factor in the cost function, simplifying the implementation. Also, methods to reduce the number of calculations necessary to implement MPC are shown and applied to cascaded H-bridge converters. These techniques allow to keep an high load current quality while reducing more than 95% in the number of calculations necessary to implement the control. Finally, other operation improvements of MPC are also included, such as fixed switching frequency operation and multistep MPC, reaching an important performance improvement compared to the basic MPC strategy.\",\"PeriodicalId\":100629,\"journal\":{\"name\":\"IEEE Open Journal of Industry Applications\",\"volume\":\"5 \",\"pages\":\"428-441\"},\"PeriodicalIF\":7.9000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10679905\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Open Journal of Industry Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10679905/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Industry Applications","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10679905/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

最近,多电平逆变器(MLIs)因其在输配电系统中的广泛应用而变得十分重要。同时,多电平逆变器的控制和调制尤其具有挑战性,因为其开关状态较多,其中许多状态在输出电压生成方面是冗余的,而且具有非线性特性。为了便于在实际环境中实施,通常会考虑模型预测控制(MPC),其主要控制目标是1) 产生所需的输出电流;2) 使内部转换器电容器电压保持在参考值。然而,在多级变流器中实施 MPC 的一个主要问题是,需要在线完成的计算数量会随着电平数的增加而急剧增加,因此在某些实际情况下几乎不可能应用 MPC。出于这些原因,多层流道 MPC 的主要研究趋势之一是提供一种算法,以减少控制操作所需的计算负担。本文对此类控制技术进行了综述。文章从基本的 MPC 实现入手,以飞行电容转换器为例,回顾了避免计算成本函数中权重因子的基本策略,从而简化了实现过程。此外,文章还介绍了减少实施 MPC 所需的计算次数的方法,并将其应用于级联 H 桥转换器。这些技术可在保持高负载电流质量的同时,将实施控制所需的计算量减少 95% 以上。最后,还包括 MPC 的其他操作改进,如固定开关频率操作和多步 MPC,与基本 MPC 策略相比,性能有了显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Model Predictive Control in Multilevel Inverters Part I: Basic Strategy and Performance Improvement
Multilevel inverters (MLIs) have lately become important due to their extended application to electrical transmission and distribution systems. At the same time, the control and modulation of MLIs are especially challenging due to the high number of switching states, many of them redundant in terms of output voltage generation, and their nonlinear characteristics. In order to ease their implementation in real environment, model predictive control (MPC) is often considered, where the main control targets are: 1) to generate a the desired output current and 2) to keep the internal converter capacitor voltages at their reference value. However, a major issue with the implementation of MPC in MLIs is that the number of calculations to be done online increases dramatically with the number of levels, making it almost impossible to apply MPC in some practical cases. For these reasons, one of the main research trend in MPC for MLIs is to provide an algorithm which can reduce the computational burden necessary to operate the control. The article proposes a review of such control techniques. Starting from the basic MPC implementation and using a flying capacitor converter as an example the article review the basic strategies to avoid calculating the weighting factor in the cost function, simplifying the implementation. Also, methods to reduce the number of calculations necessary to implement MPC are shown and applied to cascaded H-bridge converters. These techniques allow to keep an high load current quality while reducing more than 95% in the number of calculations necessary to implement the control. Finally, other operation improvements of MPC are also included, such as fixed switching frequency operation and multistep MPC, reaching an important performance improvement compared to the basic MPC strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
13.50
自引率
0.00%
发文量
0
期刊最新文献
Strategy Optimization by Means of Evolutionary Algorithms With Multiple Closing Criteria for Energy Trading A SiC Based Two-Stage Pulsed Power Converter System for Laser Diode Driving and Other Pulsed Current Applications Magnetostriction Effect on Vibration and Acoustic Noise in Permanent Magnet Synchronous Motors Model Predictive Control in Multilevel Inverters Part II: Renewable Energies and Grid Applications Model Predictive Control in Multilevel Inverters Part I: Basic Strategy and Performance Improvement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1