在混合污染源的城市集水区采用移动时间采样法量化全氟和多氟烷基物质 (PFAS) 的溪流负荷和源头输入量

Emily E. Woodward, Lisa A. Senior, Jacob A. Fleck, Larry B. Barber, Angela M. Hansen, Joseph W. Duris
{"title":"在混合污染源的城市集水区采用移动时间采样法量化全氟和多氟烷基物质 (PFAS) 的溪流负荷和源头输入量","authors":"Emily E. Woodward, Lisa A. Senior, Jacob A. Fleck, Larry B. Barber, Angela M. Hansen, Joseph W. Duris","doi":"10.1021/acsestwater.4c00288","DOIUrl":null,"url":null,"abstract":"Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km<sup>2</sup>) of the drainage area at the most downstream site (544 km<sup>2</sup>) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.","PeriodicalId":7078,"journal":{"name":"ACS Es&t Water","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment\",\"authors\":\"Emily E. Woodward, Lisa A. Senior, Jacob A. Fleck, Larry B. Barber, Angela M. Hansen, Joseph W. Duris\",\"doi\":\"10.1021/acsestwater.4c00288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km<sup>2</sup>) of the drainage area at the most downstream site (544 km<sup>2</sup>) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.\",\"PeriodicalId\":7078,\"journal\":{\"name\":\"ACS Es&t Water\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Es&t Water\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1021/acsestwater.4c00288\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Es&t Water","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acsestwater.4c00288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

了解地表水和地下水系统中的全氟和多氟烷基物质 (PFAS) 的质量分布有助于确定污染源的优先次序、减少负荷和进行水管理。我们在一个城市集水区的 13 个地点进行了采样,采用了时间-行程采样法,以最大限度地减少全氟烷基磺酸盐点源质量亚日波动的影响,并量化各种全氟烷基磺酸盐源的全氟烷基磺酸盐和辅助化学负荷。在受已知地下水排放的军事基地影响的支流下面的地点,观察到全氟烷基磺酸盐 (PFSA) 负荷(8 至 11 μg/s,最高达 618%)比全氟烷基羧酸盐 (PFCA) 负荷(无变化至 3.4 μg/s,最高达 122%)增加得更多。两个污水处理厂 (STP) 的点排放导致 PFCA 和 PFSA 负荷增加,第一个污水处理厂下方的 PFCA 和 PFSA 负荷增幅相似(分别为 6 微克/秒和 10 微克/秒),而第二个污水处理厂下方的 PFCA 和 PFSA 负荷增幅更大(分别为 23 微克/秒和 13 微克/秒)。总体而言,军事基地输入的全氟辛烷磺酸总负荷增加了 20% 到 277%,而污水处理厂输入的全氟辛烷磺酸总负荷增加了 44% 到 77%。一个仅占最下游站点(544 平方公里)排水面积 14% (76.9 平方公里)的重点集水区约占最下游站点观测到的 PFSA 负荷的 70% 和 PFCA 负荷的 40%。研究结果表明,在有多个全氟辛烷磺酸来源的混合城市环境中采用时间行程采样法,可以量化各个全氟辛烷磺酸来源的溪流负荷,从而改进来源归因,并为水资源管理者提供可操作的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment
Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km2) of the drainage area at the most downstream site (544 km2) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Evolution Mechanism of the Water Supply System in the Water Receiving Area of a Water Diversion Project Inspired by Dissipative Structure Theory Defect Engineered 2D Graphitic Carbon Nitride for Photochemical, (Bio)Electrochemical, and Microplastic Remediation Advancements Facile Synthesis of ZIF-67-Incorporated Electrospun PVA Nanofibers Composite for Efficient Pb (II) Adsorption from Water: Docking and Experimental Studies Occurrence and Removal Efficiency of Active Pharmaceutical Ingredients (APIs) in Wastewater Treatment Plants: A Systematic Review from Southeast Asia Electrochemical In Situ Production of Magnetite for the Removal of Se from Wastewater
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1