电极蒙太奇对空气传导眼前庭诱发肌源性电位频率调谐特性的影响

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY Ear and Hearing Pub Date : 2024-08-13 DOI:10.1097/aud.0000000000001560
Rajesh Kumar Raveendran,Niraj Kumar Singh
{"title":"电极蒙太奇对空气传导眼前庭诱发肌源性电位频率调谐特性的影响","authors":"Rajesh Kumar Raveendran,Niraj Kumar Singh","doi":"10.1097/aud.0000000000001560","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nThe use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages.\r\n\r\nDESIGN\r\nThirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts.\r\n\r\nRESULTS\r\nThe frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages (p < 0.008). Further, there was a \"substantial\" agreement on frequency tuning between BT and IO montages.\r\n\r\nCONCLUSIONS\r\nWith better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Electrode Montage on Frequency Tuning Properties of Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.\",\"authors\":\"Rajesh Kumar Raveendran,Niraj Kumar Singh\",\"doi\":\"10.1097/aud.0000000000001560\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES\\r\\nThe use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages.\\r\\n\\r\\nDESIGN\\r\\nThirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts.\\r\\n\\r\\nRESULTS\\r\\nThe frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages (p < 0.008). Further, there was a \\\"substantial\\\" agreement on frequency tuning between BT and IO montages.\\r\\n\\r\\nCONCLUSIONS\\r\\nWith better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.\",\"PeriodicalId\":55172,\"journal\":{\"name\":\"Ear and Hearing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ear and Hearing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/aud.0000000000001560\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/aud.0000000000001560","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:在临床记录眼前庭诱发肌源性电位(oVEMP)时,使用 500 Hz 脉冲串的频率高于其他频率,原因是该刺激频率产生的反应幅度(频率调谐)大于其他频率。然而,由于参比电极与反应源肌肉的空间位移可能导致反射污染,这就对使用眶下 (IO) 蒙太奇提出了质疑。然而,将两个记录电极都置于下斜肌上方的腹腱(BT)单体法增加了从下斜肌获得更多反应的机会。然而,这种反应是否会继续显示出频率调谐至 500 Hz 尚不清楚。因此,本研究旨在使用不同的电极蒙太奇检查 oVEMP 的频率调谐。设计38 名年轻成人在 250、500、750、1000、1500、2000、3000 和 4000 Hz 的音爆中同时接受 IO、BT、颏参照和胸骨参照电极蒙太奇的 oVEMP 记录。结果无论采用哪种单体,频率调谐最常与 750 赫兹的音爆相吻合,BT 单体的响应率明显高于其他单体,峰峰值振幅也更大(p < 0.008)。结论BT 蒙太奇具有更好的响应率和响应振幅,但频率调谐与 IO 蒙太奇相似,是临床记录不同频率 oVEMP 的更好选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Electrode Montage on Frequency Tuning Properties of Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.
OBJECTIVES The use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages. DESIGN Thirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts. RESULTS The frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages (p < 0.008). Further, there was a "substantial" agreement on frequency tuning between BT and IO montages. CONCLUSIONS With better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ear and Hearing
Ear and Hearing 医学-耳鼻喉科学
CiteScore
5.90
自引率
10.80%
发文量
207
审稿时长
6-12 weeks
期刊介绍: From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.
期刊最新文献
Associations Between Vestibular Perception and Cognitive Performance in Healthy Adults. Sounds of Nature and Hearing Loss: A Call to Action. Breathy Vocal Quality, Background Noise, and Hearing Loss: How Do These Adverse Conditions Affect Speech Perception by Older Adults? Effects of Tympanic Membrane Electrodes on Sound Transmission From the Ear Canal to the Middle and Inner Ears. The Optimal Speech-to-Background Ratio for Balancing Speech Recognition With Environmental Sound Recognition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1