Sebastian Jaenich, Tomasz Bartkowiak, Hubert Jopek, Mathias Brunnberg, Pavel Slunsky
{"title":"使用不同尺寸的聚二氧杂蒽酮缝合材料进行猫腹部开腹缝合的拉力测试:一项生物力学研究","authors":"Sebastian Jaenich, Tomasz Bartkowiak, Hubert Jopek, Mathias Brunnberg, Pavel Slunsky","doi":"10.1177/1098612x241271871","DOIUrl":null,"url":null,"abstract":"ObjectivesThe aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP).MethodsA total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2).ResultsThe frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted ( P >0.05). The risk of suture failure increased with decreasing suture size diameter.Conclusions and relevancePDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"29 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tensile testing in feline ventral abdominal coeliotomy closure with different sizes of polydioxanone suture material: a biomechanical study\",\"authors\":\"Sebastian Jaenich, Tomasz Bartkowiak, Hubert Jopek, Mathias Brunnberg, Pavel Slunsky\",\"doi\":\"10.1177/1098612x241271871\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ObjectivesThe aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP).MethodsA total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2).ResultsThe frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted ( P >0.05). The risk of suture failure increased with decreasing suture size diameter.Conclusions and relevancePDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.\",\"PeriodicalId\":15851,\"journal\":{\"name\":\"Journal of Feline Medicine and Surgery\",\"volume\":\"29 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Feline Medicine and Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1177/1098612x241271871\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612x241271871","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Tensile testing in feline ventral abdominal coeliotomy closure with different sizes of polydioxanone suture material: a biomechanical study
ObjectivesThe aim of this study was to evaluate, in vitro, the load and type of failure of the sutured ventral abdominal fascia of cats with different sizes of suture material made of polydioxanone (PDX) (2-0, 3-0, 4-0, 5-0 USP).MethodsA total of 32 samples of the ventral abdominal wall from 16 cadaveric cats were harvested using an hourglass-shaped template. The samples were sectioned longitudinally along the linea alba and then sutured together in a continuous pattern using four different randomly assigned sizes of pdx suture material (2-0, 3-0, 4-0, 5-0 USP). A universal testing machine was used for linear distraction of the samples. The tensile strength and type of failure were recorded and analysed. Three types of failure were defined: suture material failure (S), suture line failure (T1) and failure of the abdominal wall further away from the linea alba (T2).ResultsThe frequency of suture material failure decreased with increasing suture size. Suture size 5-0 failed due to a S failure in 6/8 samples, PDX 4-0 failed in 2/8 samples and PDX 3-0 failed in only 1/8 samples. However, PDX 2-0 failed due to only T1 or T2 failures, with both failures being almost equally represented. No statistically significant differences in the load to failure between PDX 2-0, 3-0 and 4-0 were noted ( P >0.05). The risk of suture failure increased with decreasing suture size diameter.Conclusions and relevancePDX 2-0 and 3-0 can be used without reservation for the closure of ventral midline coeliotomy in cats. Although there was no statistically significant difference between PDX 2-0, 3-0 and 4-0, PDX 4-0 showed a higher probability for suture breakage and should be used only after careful consideration of the patient while clinical evaluation is pending. Pdx 5-0 cannot be recommended as a safe suture size for this type of surgical closure.
期刊介绍:
JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.