在悬挂式干涉仪中集成高性能紧凑型干涉传感器

Alexandra Mitchell, Johannes Lehmann, Philip Koch, Samuel Cooper, Jesse van Dongen, Leonid Prokhorov, Nathan Holland, Michele Valentini, Conor Mow-Lowry
{"title":"在悬挂式干涉仪中集成高性能紧凑型干涉传感器","authors":"Alexandra Mitchell, Johannes Lehmann, Philip Koch, Samuel Cooper, Jesse van Dongen, Leonid Prokhorov, Nathan Holland, Michele Valentini, Conor Mow-Lowry","doi":"arxiv-2409.08843","DOIUrl":null,"url":null,"abstract":"Homodyne Quadrature Interferometers (HoQIs) are compact, low noise and high\ndynamic range displacement sensors designed for use in gravitational wave\nobservatories. Their lower noise compared to the displacement sensors used at\npresent makes them valuable for improving the seismic isolation in current and\nfuture detectors. This paper outlines the progression of this sensor from\ninitial production and benchtop tests to in-vacuum static performance and\ninstallation in a gravitational wave detector prototype facility. A detailed\ndesign description is outlined, including the full signal and optical chain\nrequired for implementation in detectors. The measured in-vacuum static\nperformance indicates a noise floor of $3-4\\times10^{-13}m/\\sqrt{\\rm{Hz}}$ at\n10Hz. Three HoQIs were installed on the beamsplitter suspension at the AEI 10m\nprototype. They measured motion of the intermediate mass across the entire\nbandwidth measured and showed minimal non-linearities and a good robustness to\nmotion in unmeasured degrees of freedom, both important for practical use in\ndynamic systems such as seismic isolation.","PeriodicalId":501374,"journal":{"name":"arXiv - PHYS - Instrumentation and Detectors","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Integration of high-performance compact interferometric sensors in a suspended interferometer\",\"authors\":\"Alexandra Mitchell, Johannes Lehmann, Philip Koch, Samuel Cooper, Jesse van Dongen, Leonid Prokhorov, Nathan Holland, Michele Valentini, Conor Mow-Lowry\",\"doi\":\"arxiv-2409.08843\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Homodyne Quadrature Interferometers (HoQIs) are compact, low noise and high\\ndynamic range displacement sensors designed for use in gravitational wave\\nobservatories. Their lower noise compared to the displacement sensors used at\\npresent makes them valuable for improving the seismic isolation in current and\\nfuture detectors. This paper outlines the progression of this sensor from\\ninitial production and benchtop tests to in-vacuum static performance and\\ninstallation in a gravitational wave detector prototype facility. A detailed\\ndesign description is outlined, including the full signal and optical chain\\nrequired for implementation in detectors. The measured in-vacuum static\\nperformance indicates a noise floor of $3-4\\\\times10^{-13}m/\\\\sqrt{\\\\rm{Hz}}$ at\\n10Hz. Three HoQIs were installed on the beamsplitter suspension at the AEI 10m\\nprototype. They measured motion of the intermediate mass across the entire\\nbandwidth measured and showed minimal non-linearities and a good robustness to\\nmotion in unmeasured degrees of freedom, both important for practical use in\\ndynamic systems such as seismic isolation.\",\"PeriodicalId\":501374,\"journal\":{\"name\":\"arXiv - PHYS - Instrumentation and Detectors\",\"volume\":\"11 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Instrumentation and Detectors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2409.08843\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2409.08843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

同调正交干涉仪(HoQIs)是专为引力波观测站设计的紧凑型、低噪声和高动态范围位移传感器。与目前使用的位移传感器相比,HoQIs 的噪声更低,因此对提高当前和未来探测器的地震隔离性能非常有价值。本文概述了这种传感器从最初的生产和台式测试到真空静态性能以及安装在引力波探测器原型设施中的过程。详细的设计说明包括在探测器中实施所需的完整信号和光学链。测得的真空静态性能表明,10Hz 时的本底噪声为 3-4 times10^{-13}m/\sqrt\{rm{Hz}}$ 。在 AEI 10m 原型的分光镜悬架上安装了三个 HoQI。它们测量了中间质量在整个测量带宽内的运动,并显示出最小的非线性和对未测量自由度运动的良好鲁棒性,这两点对于地震隔离等动态系统的实际应用都很重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Integration of high-performance compact interferometric sensors in a suspended interferometer
Homodyne Quadrature Interferometers (HoQIs) are compact, low noise and high dynamic range displacement sensors designed for use in gravitational wave observatories. Their lower noise compared to the displacement sensors used at present makes them valuable for improving the seismic isolation in current and future detectors. This paper outlines the progression of this sensor from initial production and benchtop tests to in-vacuum static performance and installation in a gravitational wave detector prototype facility. A detailed design description is outlined, including the full signal and optical chain required for implementation in detectors. The measured in-vacuum static performance indicates a noise floor of $3-4\times10^{-13}m/\sqrt{\rm{Hz}}$ at 10Hz. Three HoQIs were installed on the beamsplitter suspension at the AEI 10m prototype. They measured motion of the intermediate mass across the entire bandwidth measured and showed minimal non-linearities and a good robustness to motion in unmeasured degrees of freedom, both important for practical use in dynamic systems such as seismic isolation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy Ultraviolet cross-luminescence in ternary chlorides of alkali and alkaline-earth metals Performance Evaluation of an RFSoC Operating in a 1.25 Tesla Magnetic Field Numerical Studies of Straw Tube Detectors Advanced Halide Scintillators: From the Bulk to Nano
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1