用于评估克罗恩病患者内镜下疾病活动性的对比增强超声波峰值增强:一项荟萃分析。

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Acta radiologica Pub Date : 2024-10-01 Epub Date: 2024-09-19 DOI:10.1177/02841851241275982
Lei Yuan, Ruifang Hao, Leilei Zou, Deyin Zhai, Junlian Wang, Ruining Jiao
{"title":"用于评估克罗恩病患者内镜下疾病活动性的对比增强超声波峰值增强:一项荟萃分析。","authors":"Lei Yuan, Ruifang Hao, Leilei Zou, Deyin Zhai, Junlian Wang, Ruining Jiao","doi":"10.1177/02841851241275982","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Contrast-enhanced ultrasound (CEUS) has been proposed as a valuable tool for detecting disease activity in patients with Crohn's disease (CD). However, previous studies have utilized different parameters, leading to variation in clinical assessment of this technique.</p><p><strong>Purpose: </strong>To assess the effectiveness of peak enhancement (PE) in CEUS for evaluating endoscopic disease activity in patients with CD.</p><p><strong>Material and methods: </strong>Articles were obtained by searching PubMed, Embase, Web of Science, Wanfang, and CNKI databases. Only studies that investigated the effectiveness of PE in CEUS to discriminate endoscopic disease activity in patients with CD were considered. Pooled sensitivity and specificity were then calculated using a random effects model.</p><p><strong>Results: </strong>Overall, seven studies were included. The endoscopic disease activity of CD was determined based on the simple endoscopic score for Crohn's disease and Crohn's Disease Endoscopic Index of Severity scores. Pooled results showed that a high PE was associated with increased detection efficacy for endoscopic disease activity in CD. Pooled sensitivity, specificity, and positive and negative likelihood ratios were 0.88 (95% confidence interval [CI] = 0.71-0.96), 0.88 (95% CI = 0.81-0.93), 7.60 (95% CI = 4.61-12.53), and 0.14 (95% CI = 0.05-0.35), respectively. The pooled receiver operating characteristic was 0.90 (95% CI = 0.87-0.92), suggesting a good discriminating efficacy of PE in CEUS for endoscopic disease activity of patients with CD.</p><p><strong>Conclusions: </strong>A high PE in CEUS displayed substantial distinguishing accuracy for assessing endoscopic disease activity of patients with CD.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"1170-1177"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Peak enhancement in contrast-enhanced ultrasound for assessing endoscopic disease activity in patients with Crohn's disease: a meta-analysis.\",\"authors\":\"Lei Yuan, Ruifang Hao, Leilei Zou, Deyin Zhai, Junlian Wang, Ruining Jiao\",\"doi\":\"10.1177/02841851241275982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Contrast-enhanced ultrasound (CEUS) has been proposed as a valuable tool for detecting disease activity in patients with Crohn's disease (CD). However, previous studies have utilized different parameters, leading to variation in clinical assessment of this technique.</p><p><strong>Purpose: </strong>To assess the effectiveness of peak enhancement (PE) in CEUS for evaluating endoscopic disease activity in patients with CD.</p><p><strong>Material and methods: </strong>Articles were obtained by searching PubMed, Embase, Web of Science, Wanfang, and CNKI databases. Only studies that investigated the effectiveness of PE in CEUS to discriminate endoscopic disease activity in patients with CD were considered. Pooled sensitivity and specificity were then calculated using a random effects model.</p><p><strong>Results: </strong>Overall, seven studies were included. The endoscopic disease activity of CD was determined based on the simple endoscopic score for Crohn's disease and Crohn's Disease Endoscopic Index of Severity scores. Pooled results showed that a high PE was associated with increased detection efficacy for endoscopic disease activity in CD. Pooled sensitivity, specificity, and positive and negative likelihood ratios were 0.88 (95% confidence interval [CI] = 0.71-0.96), 0.88 (95% CI = 0.81-0.93), 7.60 (95% CI = 4.61-12.53), and 0.14 (95% CI = 0.05-0.35), respectively. The pooled receiver operating characteristic was 0.90 (95% CI = 0.87-0.92), suggesting a good discriminating efficacy of PE in CEUS for endoscopic disease activity of patients with CD.</p><p><strong>Conclusions: </strong>A high PE in CEUS displayed substantial distinguishing accuracy for assessing endoscopic disease activity of patients with CD.</p>\",\"PeriodicalId\":7143,\"journal\":{\"name\":\"Acta radiologica\",\"volume\":\" \",\"pages\":\"1170-1177\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02841851241275982\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241275982","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:对比增强超声(CEUS)被认为是检测克罗恩病患者疾病活动性的重要工具。目的:评估CEUS中峰值增强(PE)对评估CD患者内镜下疾病活动性的有效性:通过检索PubMed、Embase、Web of Science、Wanfang和CNKI数据库获得相关文章。只有研究了CEUS中的PE对CD患者内镜下疾病活动性的鉴别效果的研究才被考虑在内。然后使用随机效应模型计算汇总的敏感性和特异性:结果:共纳入七项研究。根据克罗恩病内镜下简单评分和克罗恩病内镜下严重程度指数评分确定了 CD 的内镜下疾病活动度。汇总结果显示,高PE与CD内镜下疾病活动性的检测效力增加有关。汇总的敏感性、特异性以及阳性和阴性似然比分别为 0.88(95% 置信区间 [CI] = 0.71-0.96)、0.88(95% CI = 0.81-0.93)、7.60(95% CI = 4.61-12.53)和 0.14(95% CI = 0.05-0.35)。集合接收者操作特征为0.90(95% CI = 0.87-0.92),表明CEUS中的PE对CD患者内镜下疾病活动具有良好的鉴别效果:结论:CEUS中的高PE在评估CD患者内镜下疾病活动性方面具有很高的鉴别准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Peak enhancement in contrast-enhanced ultrasound for assessing endoscopic disease activity in patients with Crohn's disease: a meta-analysis.

Background: Contrast-enhanced ultrasound (CEUS) has been proposed as a valuable tool for detecting disease activity in patients with Crohn's disease (CD). However, previous studies have utilized different parameters, leading to variation in clinical assessment of this technique.

Purpose: To assess the effectiveness of peak enhancement (PE) in CEUS for evaluating endoscopic disease activity in patients with CD.

Material and methods: Articles were obtained by searching PubMed, Embase, Web of Science, Wanfang, and CNKI databases. Only studies that investigated the effectiveness of PE in CEUS to discriminate endoscopic disease activity in patients with CD were considered. Pooled sensitivity and specificity were then calculated using a random effects model.

Results: Overall, seven studies were included. The endoscopic disease activity of CD was determined based on the simple endoscopic score for Crohn's disease and Crohn's Disease Endoscopic Index of Severity scores. Pooled results showed that a high PE was associated with increased detection efficacy for endoscopic disease activity in CD. Pooled sensitivity, specificity, and positive and negative likelihood ratios were 0.88 (95% confidence interval [CI] = 0.71-0.96), 0.88 (95% CI = 0.81-0.93), 7.60 (95% CI = 4.61-12.53), and 0.14 (95% CI = 0.05-0.35), respectively. The pooled receiver operating characteristic was 0.90 (95% CI = 0.87-0.92), suggesting a good discriminating efficacy of PE in CEUS for endoscopic disease activity of patients with CD.

Conclusions: A high PE in CEUS displayed substantial distinguishing accuracy for assessing endoscopic disease activity of patients with CD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
期刊最新文献
A diffusion kurtosis imaging study of the relationship between whole brain microstructure and cognitive function in older adults with mild cognitive impairment. Different iron distribution patterns in Parkinson's disease and its motor subtypes: a quantitative susceptibility mapping study. Impact of individually tailored contrast medium on vascular attenuation in chest CT: a randomized controlled trial. Ultrasound-guided thrombin injection for cardiac catheterization pseudoaneurysms: efficacy, safety, and predictors. Development of a nomogram based on whole-tumor multiparametric MRI histogram analysis to predict deep myometrial invasion in stage I endometrioid endometrial carcinoma preoperatively.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1