确定具有基底约束的薄膜压电系数的分析和指南。

Qinwen Xu;Jie Zhou;Shashidhara Acharya;Jianwei Chai;Mingsheng Zhang;Chengliang Sun;Kui Yao
{"title":"确定具有基底约束的薄膜压电系数的分析和指南。","authors":"Qinwen Xu;Jie Zhou;Shashidhara Acharya;Jianwei Chai;Mingsheng Zhang;Chengliang Sun;Kui Yao","doi":"10.1109/TUFFC.2024.3459593","DOIUrl":null,"url":null,"abstract":"Piezoelectric films including coatings are widely employed in various electromechanical devices. Precise measurement for piezoelectric film properties is crucial for both piezoelectric material development and design of the piezoelectric devices. However, substrate constraint on the deformation of piezoelectric films could cause significant impacts on the reliability and accuracy of the piezoelectric coefficient measurement. Through both theoretical finite element analysis (FEA) and experimental validation, here we have identified three important factors that strongly affect the measurement results: ratio of Young’s modulus of substrate to piezoelectric film, ratio of electrode size to substrate thickness, and test frequency. Our investigations show that a relatively smaller substrate’s Young’s modulus to film, and a larger ratio of electrode size to substrate thickness would cause a larger substrate bending effect and thus potentially more significant measurement errors. Moreover, intense transversal displacement fluctuation can be excited at excessively high frequencies, leading to unreliable measurements. Various well-established piezoelectric measurement methods are compared with outstanding measurement issues identified for those commonly used piezoelectric films and substrates. We further establish the guidelines for piezoelectric coefficient measurements to achieve high reliability and accuracy, thus important to the wide technical community with interests in electromechanical active materials and devices.","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"71 10","pages":"1335-1344"},"PeriodicalIF":3.0000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis and Guideline for Determining Piezoelectric Coefficient for Films With Substrate Constraint\",\"authors\":\"Qinwen Xu;Jie Zhou;Shashidhara Acharya;Jianwei Chai;Mingsheng Zhang;Chengliang Sun;Kui Yao\",\"doi\":\"10.1109/TUFFC.2024.3459593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Piezoelectric films including coatings are widely employed in various electromechanical devices. Precise measurement for piezoelectric film properties is crucial for both piezoelectric material development and design of the piezoelectric devices. However, substrate constraint on the deformation of piezoelectric films could cause significant impacts on the reliability and accuracy of the piezoelectric coefficient measurement. Through both theoretical finite element analysis (FEA) and experimental validation, here we have identified three important factors that strongly affect the measurement results: ratio of Young’s modulus of substrate to piezoelectric film, ratio of electrode size to substrate thickness, and test frequency. Our investigations show that a relatively smaller substrate’s Young’s modulus to film, and a larger ratio of electrode size to substrate thickness would cause a larger substrate bending effect and thus potentially more significant measurement errors. Moreover, intense transversal displacement fluctuation can be excited at excessively high frequencies, leading to unreliable measurements. Various well-established piezoelectric measurement methods are compared with outstanding measurement issues identified for those commonly used piezoelectric films and substrates. We further establish the guidelines for piezoelectric coefficient measurements to achieve high reliability and accuracy, thus important to the wide technical community with interests in electromechanical active materials and devices.\",\"PeriodicalId\":13322,\"journal\":{\"name\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"71 10\",\"pages\":\"1335-1344\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10679154/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10679154/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

压电薄膜(包括涂层)被广泛应用于各种机电设备中。压电薄膜特性的精确测量对于压电材料的开发和压电设备的设计都至关重要。然而,基底对压电薄膜变形的限制会对压电系数测量的可靠性和准确性产生重大影响。通过有限元理论分析和实验验证,我们确定了对测量结果影响较大的三个重要因素:基底与压电薄膜的杨氏模量比、电极尺寸与基底厚度比以及测试频率。我们的研究表明,基底与薄膜的杨氏模量之比相对较小,电极尺寸与基底厚度之比较大,会导致基底弯曲效应增大,从而可能产生更显著的测量误差。此外,过高的频率会激发强烈的横向位移波动,导致测量结果不可靠。我们比较了各种成熟的压电测量方法,并指出了常用压电薄膜和基底的突出测量问题。我们进一步确立了压电系数测量的准则,以实现高可靠性和准确性,这对于对机电活性材料和器件感兴趣的广大技术人员来说非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis and Guideline for Determining Piezoelectric Coefficient for Films With Substrate Constraint
Piezoelectric films including coatings are widely employed in various electromechanical devices. Precise measurement for piezoelectric film properties is crucial for both piezoelectric material development and design of the piezoelectric devices. However, substrate constraint on the deformation of piezoelectric films could cause significant impacts on the reliability and accuracy of the piezoelectric coefficient measurement. Through both theoretical finite element analysis (FEA) and experimental validation, here we have identified three important factors that strongly affect the measurement results: ratio of Young’s modulus of substrate to piezoelectric film, ratio of electrode size to substrate thickness, and test frequency. Our investigations show that a relatively smaller substrate’s Young’s modulus to film, and a larger ratio of electrode size to substrate thickness would cause a larger substrate bending effect and thus potentially more significant measurement errors. Moreover, intense transversal displacement fluctuation can be excited at excessively high frequencies, leading to unreliable measurements. Various well-established piezoelectric measurement methods are compared with outstanding measurement issues identified for those commonly used piezoelectric films and substrates. We further establish the guidelines for piezoelectric coefficient measurements to achieve high reliability and accuracy, thus important to the wide technical community with interests in electromechanical active materials and devices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
期刊最新文献
TinyProbe: A Wearable 32-channel Multi-Modal Wireless Ultrasound Probe. LSMD: Long-Short Memory-Based Detection Network for Carotid Artery Detection in B-mode Ultrasound Video Streams. A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells applied to COVID-19 Patients. High-frequency wearable ultrasound array belt for small animal echocardiography. Deep Power-aware Tunable Weighting for Ultrasound Microvascular Imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1