{"title":"用于评估跳跃高度的免费智能手机应用程序的并发有效性和可靠性。","authors":"Amândio Dias, Paulo Pires, Leandro Santana, Paulo Marques, Mário C Espada, Fernando Santos, Eduardo Jorge Da Silva, André Rebelo, Diogo S Teixeira","doi":"10.3390/jfmk9030155","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives</b>: Jump test assessment is commonly used for physical tests, with different type of devices used for its evaluation. The purpose of the present study was to examine the validity and reliability of a freely accessible mobile application (VertVision, version 2.0.5) for measuring jump performance. <b>Methods:</b> With that intent, thirty-eight college age recreationally active subjects underwent test assessment after a specific warm-up, performing countermovement jumps (CMJs) and squat jumps (SJs) on a contact platform while being recorded with a smartphone camera. Jump height was the criterion variable, with the same formula being used for both methods. Data analysis was performed by two experienced observers. <b>Results:</b> The results showed strong correlations with the contact platform (ICC > 0.9) for both jumps. Furthermore, between-observer reliability was also high (ICC > 0.9; CV ≤ 2.19), with lower values for smallest worthwhile change (≤0.23) and typical error of measurement (≤0.14). Estimation error varied when accounting for both observers, with the SJ accounting for bigger differences (4.1-6.03%), when compared to the CMJ (0.73-3.09%). <b>Conclusions:</b> The study suggests that VertVision is a suitable and handy method for evaluating jump performance. However, it presents a slight estimation error when compared to the contact platform.</p>","PeriodicalId":16052,"journal":{"name":"Journal of Functional Morphology and Kinesiology","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417773/pdf/","citationCount":"0","resultStr":"{\"title\":\"Concurrent Validity and Reliability of a Free Smartphone Application for Evaluation of Jump Height.\",\"authors\":\"Amândio Dias, Paulo Pires, Leandro Santana, Paulo Marques, Mário C Espada, Fernando Santos, Eduardo Jorge Da Silva, André Rebelo, Diogo S Teixeira\",\"doi\":\"10.3390/jfmk9030155\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background/Objectives</b>: Jump test assessment is commonly used for physical tests, with different type of devices used for its evaluation. The purpose of the present study was to examine the validity and reliability of a freely accessible mobile application (VertVision, version 2.0.5) for measuring jump performance. <b>Methods:</b> With that intent, thirty-eight college age recreationally active subjects underwent test assessment after a specific warm-up, performing countermovement jumps (CMJs) and squat jumps (SJs) on a contact platform while being recorded with a smartphone camera. Jump height was the criterion variable, with the same formula being used for both methods. Data analysis was performed by two experienced observers. <b>Results:</b> The results showed strong correlations with the contact platform (ICC > 0.9) for both jumps. Furthermore, between-observer reliability was also high (ICC > 0.9; CV ≤ 2.19), with lower values for smallest worthwhile change (≤0.23) and typical error of measurement (≤0.14). Estimation error varied when accounting for both observers, with the SJ accounting for bigger differences (4.1-6.03%), when compared to the CMJ (0.73-3.09%). <b>Conclusions:</b> The study suggests that VertVision is a suitable and handy method for evaluating jump performance. However, it presents a slight estimation error when compared to the contact platform.</p>\",\"PeriodicalId\":16052,\"journal\":{\"name\":\"Journal of Functional Morphology and Kinesiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417773/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Functional Morphology and Kinesiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/jfmk9030155\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPORT SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Functional Morphology and Kinesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jfmk9030155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:跳跃测试评估常用于体能测试,有不同类型的设备用于评估。本研究的目的是检验一款可免费获取的移动应用程序(VertVision,2.0.5 版)在测量跳跃表现方面的有效性和可靠性。研究方法:为此,38 名大学年龄段的娱乐活动受试者在特定热身后接受了测试评估,他们在接触式平台上进行了反身跳(CMJ)和蹲跳(SJ),同时用智能手机摄像头进行了记录。跳跃高度是标准变量,两种方法使用相同的公式。数据分析由两名经验丰富的观察员进行。结果结果表明,两种跳跃方法都与接触平台有很强的相关性(ICC > 0.9)。此外,观察者之间的可靠性也很高(ICC > 0.9;CV ≤ 2.19),最小值得变化值(≤0.23)和典型测量误差(≤0.14)的值较低。在考虑两个观察者的情况下,估计误差各不相同,与 CMJ(0.73-3.09%)相比,SJ 的估计误差更大(4.1-6.03%)。结论这项研究表明,VertVision 是一种适用且方便的评估跳跃成绩的方法。然而,与接触平台相比,它存在轻微的估计误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Concurrent Validity and Reliability of a Free Smartphone Application for Evaluation of Jump Height.

Background/Objectives: Jump test assessment is commonly used for physical tests, with different type of devices used for its evaluation. The purpose of the present study was to examine the validity and reliability of a freely accessible mobile application (VertVision, version 2.0.5) for measuring jump performance. Methods: With that intent, thirty-eight college age recreationally active subjects underwent test assessment after a specific warm-up, performing countermovement jumps (CMJs) and squat jumps (SJs) on a contact platform while being recorded with a smartphone camera. Jump height was the criterion variable, with the same formula being used for both methods. Data analysis was performed by two experienced observers. Results: The results showed strong correlations with the contact platform (ICC > 0.9) for both jumps. Furthermore, between-observer reliability was also high (ICC > 0.9; CV ≤ 2.19), with lower values for smallest worthwhile change (≤0.23) and typical error of measurement (≤0.14). Estimation error varied when accounting for both observers, with the SJ accounting for bigger differences (4.1-6.03%), when compared to the CMJ (0.73-3.09%). Conclusions: The study suggests that VertVision is a suitable and handy method for evaluating jump performance. However, it presents a slight estimation error when compared to the contact platform.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Functional Morphology and Kinesiology
Journal of Functional Morphology and Kinesiology Health Professions-Physical Therapy, Sports Therapy and Rehabilitation
CiteScore
4.20
自引率
0.00%
发文量
94
审稿时长
12 weeks
期刊最新文献
Physical Function, Self-Perceived Physical Fitness, Falls, Quality of Life and Degree of Disability According to Fear and Risk of Falling in Women with Fibromyalgia. Changes in Cardiopulmonary Capacity Parameters after Surgery: A Pilot Study Exploring the Link between Heart Function and Knee Surgery. High Versus Low-Energy Extracorporeal Shockwave Therapy for Chronic Lateral Epicondylitis: A Retrospective Study. Oxygen Consumption, Ventilatory Thresholds, and Work Zones in Nordic Walking Competitors. Physiological Profile Assessment and Self-Measurement of Healthy Students through Remote Protocol during COVID-19 Lockdown.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1