Jianping Xiang, Lei Zhang, Chenbin Rong, Rong Zou, Yumeng Hu, Yongwei Zhang, Ming Wang, Jens Fiehler, Adnan H Siddiqui, Jun Wang, Zhongrong Miao, Pengfei Yang, Shu Wan, Jianmin Liu
{"title":"从单一血管造影视图对颅内动脉粥样硬化性狭窄进行血液动力学评估的诊断准确性:一项验证研究。","authors":"Jianping Xiang, Lei Zhang, Chenbin Rong, Rong Zou, Yumeng Hu, Yongwei Zhang, Ming Wang, Jens Fiehler, Adnan H Siddiqui, Jun Wang, Zhongrong Miao, Pengfei Yang, Shu Wan, Jianmin Liu","doi":"10.1136/jnis-2024-022114","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study is to assess the feasibility of identifying the hemodynamic status of intracranial atherosclerotic stenosis (ICAS) using angio-based fractional flow (FF) calculated from a single angiographic view, with wire-based FF as the reference standard.</p><p><strong>Method: </strong>The study retrospectively recruited 100 ICAS patients who underwent pressure wire measurement and digital subtraction angiography. The AccuICAD software was used to calculate angio-based FF, with the wire-measured value serving as the reference standard for evaluating the accuracy, consistency, and diagnostic performance of angio-based FF.</p><p><strong>Results: </strong>The mean±SD value of wire-based FF was 0.77±0.18, while the mean value of angio-based FF was 0.77±0.19. A good correlation between angio-based FF and wire-based FF was evident (r=0.90, P<0.001), with good agreement (mean difference 0.00±0.08). The diagnostic accuracy of angio-based FF and percent diameter stenosis (DS%) were 93.23% versus 72.18%, 91.73% versus 72.93%, and 89.47% versus 78.95% for predicted wire-based FF thresholds of 0.70, 0.75, and 0.80, respectively. The area under the curve (AUC) values for angio-based FF and DS% were 0.975 versus 0.822, 0.970 versus 0.814, and 0.943 versus 0.826 at the respective thresholds, respectively.</p><p><strong>Conclusion: </strong>The FF calculated from a single angiographic view can be considered an effective tool for functional assessment of cerebral arterial stenosis.</p>","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":" ","pages":""},"PeriodicalIF":4.5000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of hemodynamic assessment of intracranial atherosclerotic stenosis from a single angiographic view: a validation study.\",\"authors\":\"Jianping Xiang, Lei Zhang, Chenbin Rong, Rong Zou, Yumeng Hu, Yongwei Zhang, Ming Wang, Jens Fiehler, Adnan H Siddiqui, Jun Wang, Zhongrong Miao, Pengfei Yang, Shu Wan, Jianmin Liu\",\"doi\":\"10.1136/jnis-2024-022114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The aim of this study is to assess the feasibility of identifying the hemodynamic status of intracranial atherosclerotic stenosis (ICAS) using angio-based fractional flow (FF) calculated from a single angiographic view, with wire-based FF as the reference standard.</p><p><strong>Method: </strong>The study retrospectively recruited 100 ICAS patients who underwent pressure wire measurement and digital subtraction angiography. The AccuICAD software was used to calculate angio-based FF, with the wire-measured value serving as the reference standard for evaluating the accuracy, consistency, and diagnostic performance of angio-based FF.</p><p><strong>Results: </strong>The mean±SD value of wire-based FF was 0.77±0.18, while the mean value of angio-based FF was 0.77±0.19. A good correlation between angio-based FF and wire-based FF was evident (r=0.90, P<0.001), with good agreement (mean difference 0.00±0.08). The diagnostic accuracy of angio-based FF and percent diameter stenosis (DS%) were 93.23% versus 72.18%, 91.73% versus 72.93%, and 89.47% versus 78.95% for predicted wire-based FF thresholds of 0.70, 0.75, and 0.80, respectively. The area under the curve (AUC) values for angio-based FF and DS% were 0.975 versus 0.822, 0.970 versus 0.814, and 0.943 versus 0.826 at the respective thresholds, respectively.</p><p><strong>Conclusion: </strong>The FF calculated from a single angiographic view can be considered an effective tool for functional assessment of cerebral arterial stenosis.</p>\",\"PeriodicalId\":16411,\"journal\":{\"name\":\"Journal of NeuroInterventional Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of NeuroInterventional Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/jnis-2024-022114\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2024-022114","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
Diagnostic accuracy of hemodynamic assessment of intracranial atherosclerotic stenosis from a single angiographic view: a validation study.
Background: The aim of this study is to assess the feasibility of identifying the hemodynamic status of intracranial atherosclerotic stenosis (ICAS) using angio-based fractional flow (FF) calculated from a single angiographic view, with wire-based FF as the reference standard.
Method: The study retrospectively recruited 100 ICAS patients who underwent pressure wire measurement and digital subtraction angiography. The AccuICAD software was used to calculate angio-based FF, with the wire-measured value serving as the reference standard for evaluating the accuracy, consistency, and diagnostic performance of angio-based FF.
Results: The mean±SD value of wire-based FF was 0.77±0.18, while the mean value of angio-based FF was 0.77±0.19. A good correlation between angio-based FF and wire-based FF was evident (r=0.90, P<0.001), with good agreement (mean difference 0.00±0.08). The diagnostic accuracy of angio-based FF and percent diameter stenosis (DS%) were 93.23% versus 72.18%, 91.73% versus 72.93%, and 89.47% versus 78.95% for predicted wire-based FF thresholds of 0.70, 0.75, and 0.80, respectively. The area under the curve (AUC) values for angio-based FF and DS% were 0.975 versus 0.822, 0.970 versus 0.814, and 0.943 versus 0.826 at the respective thresholds, respectively.
Conclusion: The FF calculated from a single angiographic view can be considered an effective tool for functional assessment of cerebral arterial stenosis.
期刊介绍:
The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.