用于评估勃起功能障碍的可穿戴式自适应阴茎硬度监测系统。

IF 7.3 1区 工程技术 Q1 INSTRUMENTS & INSTRUMENTATION Microsystems & Nanoengineering Pub Date : 2024-09-20 DOI:10.1038/s41378-024-00721-5
Xiangyang Wang, Ruojiang Wang, Yuyang Zhang, You Wu, Xu Wu, Zihao Luo, Yu Chang, Xiansheng Zhang, Tingrui Pan
{"title":"用于评估勃起功能障碍的可穿戴式自适应阴茎硬度监测系统。","authors":"Xiangyang Wang, Ruojiang Wang, Yuyang Zhang, You Wu, Xu Wu, Zihao Luo, Yu Chang, Xiansheng Zhang, Tingrui Pan","doi":"10.1038/s41378-024-00721-5","DOIUrl":null,"url":null,"abstract":"<p><p>Erectile dysfunction (ED) is a prevalent type of sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky and nonwearable and strongly interferes with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system that employs a measurement principle without active loads, allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. An integrated flexible printed circuit (FPC) collects and processes sensing signals, which are then transmitted to the host computer via Bluetooth for ED assessment. Additionally, we validated the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections. In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than existing technologies. Erectile dysfunction (ED) is a prevalent sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky, nonwearable, and creates pronounced interference with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system (Fig. 1a) that employs a measurement principle without active loads (Fig. 1b), allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. Additionally, we validate the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests, with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections (Fig. 1c). In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than those from existing technologies.</p>","PeriodicalId":18560,"journal":{"name":"Microsystems & Nanoengineering","volume":"10 1","pages":"131"},"PeriodicalIF":7.3000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413319/pdf/","citationCount":"0","resultStr":"{\"title\":\"A wearable adaptive penile rigidity monitoring system for assessment of erectile dysfunction.\",\"authors\":\"Xiangyang Wang, Ruojiang Wang, Yuyang Zhang, You Wu, Xu Wu, Zihao Luo, Yu Chang, Xiansheng Zhang, Tingrui Pan\",\"doi\":\"10.1038/s41378-024-00721-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Erectile dysfunction (ED) is a prevalent type of sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky and nonwearable and strongly interferes with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system that employs a measurement principle without active loads, allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. An integrated flexible printed circuit (FPC) collects and processes sensing signals, which are then transmitted to the host computer via Bluetooth for ED assessment. Additionally, we validated the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections. In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than existing technologies. Erectile dysfunction (ED) is a prevalent sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky, nonwearable, and creates pronounced interference with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system (Fig. 1a) that employs a measurement principle without active loads (Fig. 1b), allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. Additionally, we validate the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests, with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections (Fig. 1c). In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than those from existing technologies.</p>\",\"PeriodicalId\":18560,\"journal\":{\"name\":\"Microsystems & Nanoengineering\",\"volume\":\"10 1\",\"pages\":\"131\"},\"PeriodicalIF\":7.3000,\"publicationDate\":\"2024-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413319/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microsystems & Nanoengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1038/s41378-024-00721-5\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microsystems & Nanoengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1038/s41378-024-00721-5","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

勃起功能障碍(ED)是一种普遍存在的性功能障碍,在夜间自发勃起时持续监测阴茎的膨胀和硬度对其诊断和分类至关重要。然而,目前的临床标准设备受限于其主动机械负载,体积庞大且不耐磨,对勃起有强烈干扰,从而影响了监测的可靠性和患者的依从性。在此,我们报告了一种可穿戴的自适应硬度监测(WARM)系统,该系统采用无主动负载的测量原理,可通过专门设计的弹性双环传感器评估阴茎的膨胀度和硬度。双环传感器由两个具有不同弹性模量的应变传感环组成,具有高分辨率(0.1%)、强大的机械和电气稳定性(可承受 1000 次以上的循环)和很强的抗干扰性。集成的柔性印刷电路(FPC)可收集和处理传感信号,然后通过蓝牙传输到主机进行 ED 评估。此外,我们还使用阴茎模型和健康志愿者对 WARM 系统与临床标准设备进行了验证,结果一致性很高。此外,该系统还有助于在夜间勃起试验中对阴茎勃起情况进行连续评估,并同时进行睡眠监测,这证明它能够最大限度地减少对夜间勃起的干扰。总之,WARM 系统为连续、精确和方便患者的阴茎膨胀和硬度测量提供了一个完全集成的可穿戴解决方案,可能比现有技术提供更可靠、更方便的结果。勃起功能障碍(ED)是一种普遍存在的性功能障碍,持续监测夜间自发勃起时的阴茎膨胀度和硬度对其诊断和分类至关重要。然而,目前的临床标准设备受限于其主动机械负载,体积庞大,不可佩戴,对勃起造成明显干扰,从而影响了监测的可靠性和患者的依从性。在此,我们报告了一种可穿戴式自适应硬度监测(WARM)系统(图 1a),该系统采用了无主动负载的测量原理(图 1b),可通过专门设计的弹性双环传感器评估阴茎的膨胀度和硬度。双环传感器由两个具有不同弹性模量的应变传感环组成,具有高分辨率(0.1%)、强大的机械和电气稳定性(可维持 1000 次以上的循环)和很强的抗干扰性。此外,我们还使用阴茎模型和健康志愿者对 WARM 系统与临床标准设备进行了验证,结果一致性很高。此外,该系统还能在夜间勃起试验中对阴茎勃起情况进行连续评估,并同时进行睡眠监测,这证明它能最大限度地减少对夜间勃起的干扰(图 1c)。总之,WARM 系统为连续、精确和方便患者的阴茎膨胀和硬度测量提供了一个完全集成的可穿戴解决方案,与现有技术相比,它可能提供更可靠、更方便的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A wearable adaptive penile rigidity monitoring system for assessment of erectile dysfunction.

Erectile dysfunction (ED) is a prevalent type of sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky and nonwearable and strongly interferes with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system that employs a measurement principle without active loads, allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. An integrated flexible printed circuit (FPC) collects and processes sensing signals, which are then transmitted to the host computer via Bluetooth for ED assessment. Additionally, we validated the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections. In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than existing technologies. Erectile dysfunction (ED) is a prevalent sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky, nonwearable, and creates pronounced interference with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system (Fig. 1a) that employs a measurement principle without active loads (Fig. 1b), allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. Additionally, we validate the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests, with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections (Fig. 1c). In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than those from existing technologies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microsystems & Nanoengineering
Microsystems & Nanoengineering Materials Science-Materials Science (miscellaneous)
CiteScore
12.00
自引率
3.80%
发文量
123
审稿时长
20 weeks
期刊介绍: Microsystems & Nanoengineering is a comprehensive online journal that focuses on the field of Micro and Nano Electro Mechanical Systems (MEMS and NEMS). It provides a platform for researchers to share their original research findings and review articles in this area. The journal covers a wide range of topics, from fundamental research to practical applications. Published by Springer Nature, in collaboration with the Aerospace Information Research Institute, Chinese Academy of Sciences, and with the support of the State Key Laboratory of Transducer Technology, it is an esteemed publication in the field. As an open access journal, it offers free access to its content, allowing readers from around the world to benefit from the latest developments in MEMS and NEMS.
期刊最新文献
Bifunctional nanoprobe for simultaneous detection of intracellular reactive oxygen species and temperature in single cells. Sound innovations for biofabrication and tissue engineering. A novel gyroscope based on the slow surface acoustic wave in a phononic metamaterial. Defect-insensitive cylindrical surface lattice resonance array and its batch replication for enhanced immunoassay. Biomimetic hair-assisted GaN optical devices for bidirectional airflow detection.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1