吸入式西维司他钠制剂的体外雾化分析和评估。

IF 2.9 3区 综合性期刊 Q1 MULTIDISCIPLINARY SCIENCES PLoS ONE Pub Date : 2024-09-20 eCollection Date: 2024-01-01 DOI:10.1371/journal.pone.0309721
Rangdong Liu, Aifang He, Yan Xu, Yisheng Zhou, Hui Cao
{"title":"吸入式西维司他钠制剂的体外雾化分析和评估。","authors":"Rangdong Liu, Aifang He, Yan Xu, Yisheng Zhou, Hui Cao","doi":"10.1371/journal.pone.0309721","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this paper was to study in vitro atomization properties of the self-developed sodium sivelestat for inhalation, evaluate the feasibility of this preparation as an aerosol inhalation, and provide the guidance for the following animal administration experiment. Firstly, in order to ensure accurate, uniform and stable doses of the self-developed product after administration, its atomization performance was analyzed through the testing of fine particle mass and the total emitted dose, and the results of its atomization parameters meet the requirement of inhalation. Next, Atomization characteristics of two commonly used nebulizers, air compressed nebulizer and mesh nebulizer, were studied and compared. The results showed that mesh atomizers have a smaller and more uniform particle size distribution. And then, the experiment of acute lung injury induced by aerosol inhalation of lipopolysaccharide in mice was used to test the therapeutic effect of our self-developed formulation, and compared with the positive control (sodium sivelestat for injection). The results showed that inhalation had a lower concentration and was equally effective than injection of sodium sivelestat. All the results support that the self-developed sodium sivelestat can be used as an aerosol inhaled drug.</p>","PeriodicalId":20189,"journal":{"name":"PLoS ONE","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414907/pdf/","citationCount":"0","resultStr":"{\"title\":\"In vitro atomization analysis and evaluation of inhalable sodium sivelestat formulations.\",\"authors\":\"Rangdong Liu, Aifang He, Yan Xu, Yisheng Zhou, Hui Cao\",\"doi\":\"10.1371/journal.pone.0309721\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this paper was to study in vitro atomization properties of the self-developed sodium sivelestat for inhalation, evaluate the feasibility of this preparation as an aerosol inhalation, and provide the guidance for the following animal administration experiment. Firstly, in order to ensure accurate, uniform and stable doses of the self-developed product after administration, its atomization performance was analyzed through the testing of fine particle mass and the total emitted dose, and the results of its atomization parameters meet the requirement of inhalation. Next, Atomization characteristics of two commonly used nebulizers, air compressed nebulizer and mesh nebulizer, were studied and compared. The results showed that mesh atomizers have a smaller and more uniform particle size distribution. And then, the experiment of acute lung injury induced by aerosol inhalation of lipopolysaccharide in mice was used to test the therapeutic effect of our self-developed formulation, and compared with the positive control (sodium sivelestat for injection). The results showed that inhalation had a lower concentration and was equally effective than injection of sodium sivelestat. All the results support that the self-developed sodium sivelestat can be used as an aerosol inhaled drug.</p>\",\"PeriodicalId\":20189,\"journal\":{\"name\":\"PLoS ONE\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414907/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PLoS ONE\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.1371/journal.pone.0309721\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PLoS ONE","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1371/journal.pone.0309721","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

本文旨在研究自主研发的吸入用西维司他钠的体外雾化性能,评价该制剂作为气雾吸入剂的可行性,为后续的动物给药实验提供指导。首先,为了保证自主研发产品给药后剂量的准确、均匀和稳定,通过对细小颗粒质量和总发射剂量的测试,分析了其雾化性能,结果显示其雾化参数符合吸入要求。接着,研究并比较了两种常用雾化器(空气压缩雾化器和网状雾化器)的雾化特性。结果表明,网状雾化器的粒度分布更小、更均匀。然后,利用小鼠气溶胶吸入脂多糖诱发急性肺损伤的实验来检验我们自主研发的制剂的治疗效果,并与阳性对照(注射用西维司他钠)进行比较。结果表明,与注射西维司他钠相比,吸入的浓度较低,效果相当。所有结果都证明,自主研发的西维司他钠可用作气雾吸入药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro atomization analysis and evaluation of inhalable sodium sivelestat formulations.

The purpose of this paper was to study in vitro atomization properties of the self-developed sodium sivelestat for inhalation, evaluate the feasibility of this preparation as an aerosol inhalation, and provide the guidance for the following animal administration experiment. Firstly, in order to ensure accurate, uniform and stable doses of the self-developed product after administration, its atomization performance was analyzed through the testing of fine particle mass and the total emitted dose, and the results of its atomization parameters meet the requirement of inhalation. Next, Atomization characteristics of two commonly used nebulizers, air compressed nebulizer and mesh nebulizer, were studied and compared. The results showed that mesh atomizers have a smaller and more uniform particle size distribution. And then, the experiment of acute lung injury induced by aerosol inhalation of lipopolysaccharide in mice was used to test the therapeutic effect of our self-developed formulation, and compared with the positive control (sodium sivelestat for injection). The results showed that inhalation had a lower concentration and was equally effective than injection of sodium sivelestat. All the results support that the self-developed sodium sivelestat can be used as an aerosol inhaled drug.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
PLoS ONE
PLoS ONE 生物-生物学
CiteScore
6.20
自引率
5.40%
发文量
14242
审稿时长
3.7 months
期刊介绍: PLOS ONE is an international, peer-reviewed, open-access, online publication. PLOS ONE welcomes reports on primary research from any scientific discipline. It provides: * Open-access—freely accessible online, authors retain copyright * Fast publication times * Peer review by expert, practicing researchers * Post-publication tools to indicate quality and impact * Community-based dialogue on articles * Worldwide media coverage
期刊最新文献
"What does this mean for our future?" uncertainty management in mothers' narratives about the diagnosis and birth of their child with Down syndrome. A multimodal understanding of the role of sound and music in gendered toy marketing. Evaluation of the Vaginal Panel Realtime PCR kit (Vircell, SL) for diagnosing vaginitis: A comparative study with routinely used diagnostics. Fault-tolerant partition resolvability of cycle with chord. Few-shot learning for inference in medical imaging with subspace feature representations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1