食管鳞状细胞癌术前双能计算机断层扫描和正电子发射断层扫描淋巴结转移评估。

IF 2.9 3区 综合性期刊 Q1 MULTIDISCIPLINARY SCIENCES PLoS ONE Pub Date : 2024-09-20 eCollection Date: 2024-01-01 DOI:10.1371/journal.pone.0309653
Xuyang Sun, Tetsu Niwa, Toshiki Kazama, Takashi Okazaki, Kazuo Koyanagi, Nobue Kumaki, Jun Hashimoto, Soji Ozawa
{"title":"食管鳞状细胞癌术前双能计算机断层扫描和正电子发射断层扫描淋巴结转移评估。","authors":"Xuyang Sun, Tetsu Niwa, Toshiki Kazama, Takashi Okazaki, Kazuo Koyanagi, Nobue Kumaki, Jun Hashimoto, Soji Ozawa","doi":"10.1371/journal.pone.0309653","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the detectability of lymph node metastasis in patients with esophageal squamous cell carcinoma using a combination of dual-energy computed tomography (CT) and positron-emission tomography (PET) parameters.</p><p><strong>Methods: </strong>We analyzed dual-energy CT and PET preoperative data in 27 consecutive patients with esophageal squamous cell carcinoma (23 men, 4 women; mean age, 73.7 years). We selected lymph nodes with a short-axis diameter of ≥5 mm and measured CT values, iodine concentrations, fat fractions, long- and short-axis diameters, and ratio of long- and short-axis diameters. We performed visual assessment of lymph node characteristics based on dual-energy CT and determined the maximum standardized uptake value via PET. The measured values were postoperatively compared between pathologically confirmed metastatic and nonmetastatic lymph nodes. Stepwise logistic regression analysis was performed to determine factors associated with lymph node metastasis. Diagnostic accuracy was assessed via receiver operating characteristic curve analysis.</p><p><strong>Results: </strong>Overall, 18 metastatic and 37 nonmetastatic lymph nodes were detected. CT values, iodine concentrations, fat fractions, and the maximum standardized uptake values differed significantly between metastatic and nonmetastatic lymph nodes (p < 0.05). Stepwise logistic regression showed that iodine concentration and the maximum standardized uptake value were significant predictors of metastatic lymph nodes. The areas under the curve of iodine concentrations and maximum standardized uptake values were 0.809 and 0.833, respectively. The area under the curve of the combined parameters was 0.884, with 83.3% sensitivity and 86.5% specificity.</p><p><strong>Conclusion: </strong>Combined dual-energy CT and PET parameters improved the diagnosis of lymph node metastasis in patients with esophageal cancer.</p>","PeriodicalId":20189,"journal":{"name":"PLoS ONE","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414887/pdf/","citationCount":"0","resultStr":"{\"title\":\"Preoperative dual-energy computed tomography and positron-emission tomography evaluation of lymph node metastasis in esophageal squamous cell carcinoma.\",\"authors\":\"Xuyang Sun, Tetsu Niwa, Toshiki Kazama, Takashi Okazaki, Kazuo Koyanagi, Nobue Kumaki, Jun Hashimoto, Soji Ozawa\",\"doi\":\"10.1371/journal.pone.0309653\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the detectability of lymph node metastasis in patients with esophageal squamous cell carcinoma using a combination of dual-energy computed tomography (CT) and positron-emission tomography (PET) parameters.</p><p><strong>Methods: </strong>We analyzed dual-energy CT and PET preoperative data in 27 consecutive patients with esophageal squamous cell carcinoma (23 men, 4 women; mean age, 73.7 years). We selected lymph nodes with a short-axis diameter of ≥5 mm and measured CT values, iodine concentrations, fat fractions, long- and short-axis diameters, and ratio of long- and short-axis diameters. We performed visual assessment of lymph node characteristics based on dual-energy CT and determined the maximum standardized uptake value via PET. The measured values were postoperatively compared between pathologically confirmed metastatic and nonmetastatic lymph nodes. Stepwise logistic regression analysis was performed to determine factors associated with lymph node metastasis. Diagnostic accuracy was assessed via receiver operating characteristic curve analysis.</p><p><strong>Results: </strong>Overall, 18 metastatic and 37 nonmetastatic lymph nodes were detected. CT values, iodine concentrations, fat fractions, and the maximum standardized uptake values differed significantly between metastatic and nonmetastatic lymph nodes (p < 0.05). Stepwise logistic regression showed that iodine concentration and the maximum standardized uptake value were significant predictors of metastatic lymph nodes. The areas under the curve of iodine concentrations and maximum standardized uptake values were 0.809 and 0.833, respectively. The area under the curve of the combined parameters was 0.884, with 83.3% sensitivity and 86.5% specificity.</p><p><strong>Conclusion: </strong>Combined dual-energy CT and PET parameters improved the diagnosis of lymph node metastasis in patients with esophageal cancer.</p>\",\"PeriodicalId\":20189,\"journal\":{\"name\":\"PLoS ONE\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414887/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PLoS ONE\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.1371/journal.pone.0309653\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PLoS ONE","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1371/journal.pone.0309653","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preoperative dual-energy computed tomography and positron-emission tomography evaluation of lymph node metastasis in esophageal squamous cell carcinoma.

Purpose: To investigate the detectability of lymph node metastasis in patients with esophageal squamous cell carcinoma using a combination of dual-energy computed tomography (CT) and positron-emission tomography (PET) parameters.

Methods: We analyzed dual-energy CT and PET preoperative data in 27 consecutive patients with esophageal squamous cell carcinoma (23 men, 4 women; mean age, 73.7 years). We selected lymph nodes with a short-axis diameter of ≥5 mm and measured CT values, iodine concentrations, fat fractions, long- and short-axis diameters, and ratio of long- and short-axis diameters. We performed visual assessment of lymph node characteristics based on dual-energy CT and determined the maximum standardized uptake value via PET. The measured values were postoperatively compared between pathologically confirmed metastatic and nonmetastatic lymph nodes. Stepwise logistic regression analysis was performed to determine factors associated with lymph node metastasis. Diagnostic accuracy was assessed via receiver operating characteristic curve analysis.

Results: Overall, 18 metastatic and 37 nonmetastatic lymph nodes were detected. CT values, iodine concentrations, fat fractions, and the maximum standardized uptake values differed significantly between metastatic and nonmetastatic lymph nodes (p < 0.05). Stepwise logistic regression showed that iodine concentration and the maximum standardized uptake value were significant predictors of metastatic lymph nodes. The areas under the curve of iodine concentrations and maximum standardized uptake values were 0.809 and 0.833, respectively. The area under the curve of the combined parameters was 0.884, with 83.3% sensitivity and 86.5% specificity.

Conclusion: Combined dual-energy CT and PET parameters improved the diagnosis of lymph node metastasis in patients with esophageal cancer.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
PLoS ONE
PLoS ONE 生物-生物学
CiteScore
6.20
自引率
5.40%
发文量
14242
审稿时长
3.7 months
期刊介绍: PLOS ONE is an international, peer-reviewed, open-access, online publication. PLOS ONE welcomes reports on primary research from any scientific discipline. It provides: * Open-access—freely accessible online, authors retain copyright * Fast publication times * Peer review by expert, practicing researchers * Post-publication tools to indicate quality and impact * Community-based dialogue on articles * Worldwide media coverage
期刊最新文献
A multi-centre, tolerability study of a cannabidiol-enriched Cannabis Herbal Extract for chronic headaches in adolescents: The CAN-CHA protocol. A Stackelberg-based repurchase strategy for rail freight options (BRFO). Additional predictors of stroke and transient ischaemic attack in BEFAST positive patients in out-of-hours emergency primary care. Detection and prevalence of a novel Bandavirus related to Guertu virus in Amblyomma gemma ticks and human populations in Isiolo County, Kenya. Anatomical and Micro-CT measurement analysis of ocular volume and intraocular volume in adult Bama Miniature pigs, New Zealand rabbits, and Sprague-Dawley rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1