内镜减肥疗法与肥胖症之争:内镜袖带胃成形术与内镜插入胃内球囊--一项对比研究的成对分析及对随机对照试验的呼吁》(Endoscopic Sleeve Gastroplasty Versus Endoscopically Inserted Intragastric Balloon- A Pairwise Meta-Analysis of Comparative Studies and a Call for Randomized Controlled Trials)。
Abdul-Rahman F Diab, Joseph A Sujka, Kathleen Mattingly, Mehak Sachdeva, Kenneth Hackbarth, Salvatore Docimo, Christopher G DuCoin
{"title":"内镜减肥疗法与肥胖症之争:内镜袖带胃成形术与内镜插入胃内球囊--一项对比研究的成对分析及对随机对照试验的呼吁》(Endoscopic Sleeve Gastroplasty Versus Endoscopically Inserted Intragastric Balloon- A Pairwise Meta-Analysis of Comparative Studies and a Call for Randomized Controlled Trials)。","authors":"Abdul-Rahman F Diab, Joseph A Sujka, Kathleen Mattingly, Mehak Sachdeva, Kenneth Hackbarth, Salvatore Docimo, Christopher G DuCoin","doi":"10.1097/SLE.0000000000001321","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endoscopic sleeve gastroplasty (ESG) represents the latest primary endoscopic intervention for managing obesity. Both ESG and intragastric balloons (IGBs) have demonstrated effectiveness and safety for weight loss. However, there is a paucity of high-quality evidence supporting the superiority of one over the other, and no pairwise meta-analysis of comparative studies has been published to date. Our aim was to conduct a pairwise meta-analysis of comparative studies directly comparing ESG and IGB.</p><p><strong>Methods: </strong>We systematically conducted a literature search on PubMed and Google Scholar following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Our search used specific search terms. The Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) Tool was used to evaluate the quality of the included studies. Data were analyzed using Review Manager (RevMan) 5.4.1 software with a random-effects model. The statistical method used was the Mantel-Haenszel method. For dichotomous data, the effect size was represented using odds ratio (OR), while mean difference (MD) was utilized as the effect size for continuous data.</p><p><strong>Results: </strong>After screening 967 records, a total of 9 studies met the inclusion criteria for this meta-analysis (5302 patients). The quality assessment categorized 5 studies as having a moderate risk of bias, while 3 studies were classified as having a low risk of bias. Sufficient information was not available for one study to ascertain its overall quality. A statistically significant increase in total weight loss percentage (TWL%) at 1 and 6 months was observed with ESG compared with IGB. In addition, a statistically insignificant decrease in the incidence of adverse events and readmissions was observed with ESG. Furthermore, a statistically significant decrease in the incidence of reintervention was observed with ESG.</p><p><strong>Conclusions: </strong>While this study suggests a higher TWL% associated with ESG compared with IGB, drawing definitive conclusions is challenging due to limitations identified during a comprehensive quality assessment of the available literature. We advocate for randomized controlled trials (RCTs) directly comparing the newer IGB (with a 12-mo placement duration) with ESG. However, this study consistently reveals higher rates of early reintervention (re-endoscopy) within the IGB group, primarily necessitated by the removal or adjustment of the IGB due to intolerance. Given the additional intervention required at 6 or 12 months to remove the temporarily placed IGB, this trend may imply that IGB is less economically viable than ESG. Cost-effectiveness analyses comparing ESG and IGB are warranted to provide valuable scientific insights.</p>","PeriodicalId":22092,"journal":{"name":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Battle of Endoscopic Bariatric Therapies for Obesity: Endoscopic Sleeve Gastroplasty Versus Endoscopically Inserted Intragastric Balloon-A Pairwise Meta-Analysis of Comparative Studies and a Call for Randomized Controlled Trials.\",\"authors\":\"Abdul-Rahman F Diab, Joseph A Sujka, Kathleen Mattingly, Mehak Sachdeva, Kenneth Hackbarth, Salvatore Docimo, Christopher G DuCoin\",\"doi\":\"10.1097/SLE.0000000000001321\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Endoscopic sleeve gastroplasty (ESG) represents the latest primary endoscopic intervention for managing obesity. Both ESG and intragastric balloons (IGBs) have demonstrated effectiveness and safety for weight loss. However, there is a paucity of high-quality evidence supporting the superiority of one over the other, and no pairwise meta-analysis of comparative studies has been published to date. Our aim was to conduct a pairwise meta-analysis of comparative studies directly comparing ESG and IGB.</p><p><strong>Methods: </strong>We systematically conducted a literature search on PubMed and Google Scholar following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Our search used specific search terms. The Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) Tool was used to evaluate the quality of the included studies. Data were analyzed using Review Manager (RevMan) 5.4.1 software with a random-effects model. The statistical method used was the Mantel-Haenszel method. For dichotomous data, the effect size was represented using odds ratio (OR), while mean difference (MD) was utilized as the effect size for continuous data.</p><p><strong>Results: </strong>After screening 967 records, a total of 9 studies met the inclusion criteria for this meta-analysis (5302 patients). The quality assessment categorized 5 studies as having a moderate risk of bias, while 3 studies were classified as having a low risk of bias. Sufficient information was not available for one study to ascertain its overall quality. A statistically significant increase in total weight loss percentage (TWL%) at 1 and 6 months was observed with ESG compared with IGB. In addition, a statistically insignificant decrease in the incidence of adverse events and readmissions was observed with ESG. Furthermore, a statistically significant decrease in the incidence of reintervention was observed with ESG.</p><p><strong>Conclusions: </strong>While this study suggests a higher TWL% associated with ESG compared with IGB, drawing definitive conclusions is challenging due to limitations identified during a comprehensive quality assessment of the available literature. We advocate for randomized controlled trials (RCTs) directly comparing the newer IGB (with a 12-mo placement duration) with ESG. However, this study consistently reveals higher rates of early reintervention (re-endoscopy) within the IGB group, primarily necessitated by the removal or adjustment of the IGB due to intolerance. Given the additional intervention required at 6 or 12 months to remove the temporarily placed IGB, this trend may imply that IGB is less economically viable than ESG. Cost-effectiveness analyses comparing ESG and IGB are warranted to provide valuable scientific insights.</p>\",\"PeriodicalId\":22092,\"journal\":{\"name\":\"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/SLE.0000000000001321\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SLE.0000000000001321","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
The Battle of Endoscopic Bariatric Therapies for Obesity: Endoscopic Sleeve Gastroplasty Versus Endoscopically Inserted Intragastric Balloon-A Pairwise Meta-Analysis of Comparative Studies and a Call for Randomized Controlled Trials.
Background: Endoscopic sleeve gastroplasty (ESG) represents the latest primary endoscopic intervention for managing obesity. Both ESG and intragastric balloons (IGBs) have demonstrated effectiveness and safety for weight loss. However, there is a paucity of high-quality evidence supporting the superiority of one over the other, and no pairwise meta-analysis of comparative studies has been published to date. Our aim was to conduct a pairwise meta-analysis of comparative studies directly comparing ESG and IGB.
Methods: We systematically conducted a literature search on PubMed and Google Scholar following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Our search used specific search terms. The Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) Tool was used to evaluate the quality of the included studies. Data were analyzed using Review Manager (RevMan) 5.4.1 software with a random-effects model. The statistical method used was the Mantel-Haenszel method. For dichotomous data, the effect size was represented using odds ratio (OR), while mean difference (MD) was utilized as the effect size for continuous data.
Results: After screening 967 records, a total of 9 studies met the inclusion criteria for this meta-analysis (5302 patients). The quality assessment categorized 5 studies as having a moderate risk of bias, while 3 studies were classified as having a low risk of bias. Sufficient information was not available for one study to ascertain its overall quality. A statistically significant increase in total weight loss percentage (TWL%) at 1 and 6 months was observed with ESG compared with IGB. In addition, a statistically insignificant decrease in the incidence of adverse events and readmissions was observed with ESG. Furthermore, a statistically significant decrease in the incidence of reintervention was observed with ESG.
Conclusions: While this study suggests a higher TWL% associated with ESG compared with IGB, drawing definitive conclusions is challenging due to limitations identified during a comprehensive quality assessment of the available literature. We advocate for randomized controlled trials (RCTs) directly comparing the newer IGB (with a 12-mo placement duration) with ESG. However, this study consistently reveals higher rates of early reintervention (re-endoscopy) within the IGB group, primarily necessitated by the removal or adjustment of the IGB due to intolerance. Given the additional intervention required at 6 or 12 months to remove the temporarily placed IGB, this trend may imply that IGB is less economically viable than ESG. Cost-effectiveness analyses comparing ESG and IGB are warranted to provide valuable scientific insights.
期刊介绍:
Surgical Laparoscopy Endoscopy & Percutaneous Techniques is a primary source for peer-reviewed, original articles on the newest techniques and applications in operative laparoscopy and endoscopy. Its Editorial Board includes many of the surgeons who pioneered the use of these revolutionary techniques. The journal provides complete, timely, accurate, practical coverage of laparoscopic and endoscopic techniques and procedures; current clinical and basic science research; preoperative and postoperative patient management; complications in laparoscopic and endoscopic surgery; and new developments in instrumentation and technology.