[交叉反应碳水化合物抗原决定簇抗体吸附剂在鉴定过敏原特异性 IgE 抗体中的有效性分析]。

W L Zhao, B Cai, C Q Shi, Z Z Su, W H Feng
{"title":"[交叉反应碳水化合物抗原决定簇抗体吸附剂在鉴定过敏原特异性 IgE 抗体中的有效性分析]。","authors":"W L Zhao, B Cai, C Q Shi, Z Z Su, W H Feng","doi":"10.3760/cma.j.cn112150-20240615-00475","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the influence of anti-cross-reactive carbohydrate determinant IgE antibodies (anti-CCD IgE) on the detection of allergen-specific IgE (sIgE) antibodies, as well as the application value of anti-CCD IgE adsorbents in detecting allergen sIgE. In this cross-sectional study, a total of 2 636 test samples from patients who received treatment in West China Hospital of Sichuan University and tested allergen sIgE using the western blot method from October 2020 to May 2021 were analyzed. In these samples, 709 samples tested postive of allergen sIgE. 46 stochastic venous serum samples that tested positive in both sIgE and anti-CCD IgE and 1 serum sample that tested positive in sIgE but negative in anti-CCD IgE were collected. These samples were processed by anti-CCD IgE adsorbents, followed by allergen sIgE detection. The difference between the two detection results before and after adsorption was analyzed. The allergen test results showed that the positive rate of anti-CCD IgE in samples was 2.6% (69/2 636) during the period of sample collection. After treatment with anti-CCD IgE adsorbents, the top three allergen-sIgE of the positive rate changed from tree combination 2 (willow/poplar/elm), common ragweed and peanut to dust mite combination, cockroach and crab. The positive anti-CCD IgE results of 46 samples all turned negative and the total positive sIgE antibody dropped by 62.8%; the positive rate of sIgE antibodies with the class result ≥2 significantly decreased after treatment with anti-CCD IgE adsorbents, especially the positive rate of common ragweed dropped by 96.2%. The results of positive samples showed that multiple sIgE antibodies declined by different ranges, involving up to 11 antibodies with a maximum decline of 4 classes. Strongly positive sIgE antibodies (the class result ≥4) also had a high conversion rate of negative (25.0%-100%). The positive sIgE antibodies in about 60% of the samples decreased by more than 2, and the sIgE antibodies in 17.4% of the samples turned completely negative. There was no change in the allergen sIgE detection results of the sample with negative anti-CCD IgE after treatment. In conclusion, sIgE antibodies including targeting common ragweed, humulus, tree combination 2 (willow/poplar/elm), etc. are susceptible to false positives caused by anti-CCD IgE. Treatment of samples with anti-CCD IgE adsorbents can significantly reduce the risk of false positives caused by anti-CCD IgE. It is necessary to pretreat samples that were anti-CCD IgE positive with anti-CCD IgE adsorbents, which can make laboratory results more accurate and provide a reference for diagnosis and prevention of allergic diseases.</p>","PeriodicalId":24033,"journal":{"name":"中华预防医学杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Analysis of the effectiveness of cross-reactive carbohydrate antigen determinant antibody adsorbents in identifying allergen-specific IgE antibodies].\",\"authors\":\"W L Zhao, B Cai, C Q Shi, Z Z Su, W H Feng\",\"doi\":\"10.3760/cma.j.cn112150-20240615-00475\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to investigate the influence of anti-cross-reactive carbohydrate determinant IgE antibodies (anti-CCD IgE) on the detection of allergen-specific IgE (sIgE) antibodies, as well as the application value of anti-CCD IgE adsorbents in detecting allergen sIgE. In this cross-sectional study, a total of 2 636 test samples from patients who received treatment in West China Hospital of Sichuan University and tested allergen sIgE using the western blot method from October 2020 to May 2021 were analyzed. In these samples, 709 samples tested postive of allergen sIgE. 46 stochastic venous serum samples that tested positive in both sIgE and anti-CCD IgE and 1 serum sample that tested positive in sIgE but negative in anti-CCD IgE were collected. These samples were processed by anti-CCD IgE adsorbents, followed by allergen sIgE detection. The difference between the two detection results before and after adsorption was analyzed. The allergen test results showed that the positive rate of anti-CCD IgE in samples was 2.6% (69/2 636) during the period of sample collection. After treatment with anti-CCD IgE adsorbents, the top three allergen-sIgE of the positive rate changed from tree combination 2 (willow/poplar/elm), common ragweed and peanut to dust mite combination, cockroach and crab. The positive anti-CCD IgE results of 46 samples all turned negative and the total positive sIgE antibody dropped by 62.8%; the positive rate of sIgE antibodies with the class result ≥2 significantly decreased after treatment with anti-CCD IgE adsorbents, especially the positive rate of common ragweed dropped by 96.2%. The results of positive samples showed that multiple sIgE antibodies declined by different ranges, involving up to 11 antibodies with a maximum decline of 4 classes. Strongly positive sIgE antibodies (the class result ≥4) also had a high conversion rate of negative (25.0%-100%). The positive sIgE antibodies in about 60% of the samples decreased by more than 2, and the sIgE antibodies in 17.4% of the samples turned completely negative. There was no change in the allergen sIgE detection results of the sample with negative anti-CCD IgE after treatment. In conclusion, sIgE antibodies including targeting common ragweed, humulus, tree combination 2 (willow/poplar/elm), etc. are susceptible to false positives caused by anti-CCD IgE. Treatment of samples with anti-CCD IgE adsorbents can significantly reduce the risk of false positives caused by anti-CCD IgE. It is necessary to pretreat samples that were anti-CCD IgE positive with anti-CCD IgE adsorbents, which can make laboratory results more accurate and provide a reference for diagnosis and prevention of allergic diseases.</p>\",\"PeriodicalId\":24033,\"journal\":{\"name\":\"中华预防医学杂志\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华预防医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112150-20240615-00475\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华预防医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112150-20240615-00475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在探讨抗交叉反应性碳水化合物决定簇IgE抗体(抗CCD IgE)对过敏原特异性IgE(sIgE)抗体检测的影响,以及抗CCD IgE吸附剂在检测过敏原sIgE中的应用价值。在这项横断面研究中,我们分析了2020年10月至2021年5月期间在四川大学华西医院接受治疗并使用Western印迹法检测过敏原sIgE的患者的2 636份检测样本。在这些样本中,709 份样本的过敏原 sIgE 检测呈阳性。此外,还收集了 46 份随机静脉血清样本(sIgE 和抗CCD IgE 均呈阳性)和 1 份血清样本(sIgE 呈阳性,抗CCD IgE 呈阴性)。这些样本经抗CCD IgE 吸附剂处理后,再进行过敏原 sIgE 检测。分析了吸附前后两次检测结果的差异。过敏原检测结果表明,在样本采集期间,样本中的抗CCD IgE 阳性率为 2.6%(69/2 636)。经抗CCD IgE 吸附剂处理后,阳性率前三位的过敏原-SIgE 由树木组合 2(柳树/杨树/榆树)、普通豚草和花生变为尘螨组合、蟑螂和螃蟹。46 份样本的抗 CD IgE 阳性结果全部转阴,sIgE 抗体总阳性率下降了 62.8%;经抗 CD IgE 吸附剂处理后,sIgE 抗体≥2 级的阳性率明显下降,尤其是普通豚草的阳性率下降了 96.2%。阳性样本的结果显示,多种 sIgE 抗体的下降幅度不同,最多涉及 11 种抗体,最大下降幅度为 4 级。强阳性 sIgE 抗体(结果≥4 级)的阴转率也很高(25.0%-100%)。约 60% 样本的 sIgE 阳性抗体下降超过 2,17.4% 样本的 sIgE 抗体完全转阴。抗CCD IgE 阴性样本的过敏原 sIgE 检测结果在治疗后没有变化。总之,针对普通豚草、葎草、树木组合 2(柳树/杨树/榆树)等的 sIgE 抗体容易受到抗CCD IgE 的影响而出现假阳性。用抗滴滴涕 IgE 吸附剂处理样本可大大降低抗滴滴涕 IgE 造成假阳性的风险。因此,有必要用抗-CDD IgE 吸附剂对抗-CDD IgE 阳性的样本进行预处理,使实验室结果更加准确,为过敏性疾病的诊断和预防提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Analysis of the effectiveness of cross-reactive carbohydrate antigen determinant antibody adsorbents in identifying allergen-specific IgE antibodies].

This study aimed to investigate the influence of anti-cross-reactive carbohydrate determinant IgE antibodies (anti-CCD IgE) on the detection of allergen-specific IgE (sIgE) antibodies, as well as the application value of anti-CCD IgE adsorbents in detecting allergen sIgE. In this cross-sectional study, a total of 2 636 test samples from patients who received treatment in West China Hospital of Sichuan University and tested allergen sIgE using the western blot method from October 2020 to May 2021 were analyzed. In these samples, 709 samples tested postive of allergen sIgE. 46 stochastic venous serum samples that tested positive in both sIgE and anti-CCD IgE and 1 serum sample that tested positive in sIgE but negative in anti-CCD IgE were collected. These samples were processed by anti-CCD IgE adsorbents, followed by allergen sIgE detection. The difference between the two detection results before and after adsorption was analyzed. The allergen test results showed that the positive rate of anti-CCD IgE in samples was 2.6% (69/2 636) during the period of sample collection. After treatment with anti-CCD IgE adsorbents, the top three allergen-sIgE of the positive rate changed from tree combination 2 (willow/poplar/elm), common ragweed and peanut to dust mite combination, cockroach and crab. The positive anti-CCD IgE results of 46 samples all turned negative and the total positive sIgE antibody dropped by 62.8%; the positive rate of sIgE antibodies with the class result ≥2 significantly decreased after treatment with anti-CCD IgE adsorbents, especially the positive rate of common ragweed dropped by 96.2%. The results of positive samples showed that multiple sIgE antibodies declined by different ranges, involving up to 11 antibodies with a maximum decline of 4 classes. Strongly positive sIgE antibodies (the class result ≥4) also had a high conversion rate of negative (25.0%-100%). The positive sIgE antibodies in about 60% of the samples decreased by more than 2, and the sIgE antibodies in 17.4% of the samples turned completely negative. There was no change in the allergen sIgE detection results of the sample with negative anti-CCD IgE after treatment. In conclusion, sIgE antibodies including targeting common ragweed, humulus, tree combination 2 (willow/poplar/elm), etc. are susceptible to false positives caused by anti-CCD IgE. Treatment of samples with anti-CCD IgE adsorbents can significantly reduce the risk of false positives caused by anti-CCD IgE. It is necessary to pretreat samples that were anti-CCD IgE positive with anti-CCD IgE adsorbents, which can make laboratory results more accurate and provide a reference for diagnosis and prevention of allergic diseases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华预防医学杂志
中华预防医学杂志 Medicine-Medicine (all)
CiteScore
1.20
自引率
0.00%
发文量
12678
期刊介绍: Chinese Journal of Preventive Medicine (CJPM), the successor to Chinese Health Journal , was initiated on October 1, 1953. In 1960, it was amalgamated with the Chinese Medical Journal and the Journal of Medical History and Health Care , and thereafter, was renamed as People’s Care . On November 25, 1978, the publication was denominated as Chinese Journal of Preventive Medicine . The contents of CJPM deal with a wide range of disciplines and technologies including epidemiology, environmental health, nutrition and food hygiene, occupational health, hygiene for children and adolescents, radiological health, toxicology, biostatistics, social medicine, pathogenic and epidemiological research in malignant tumor, surveillance and immunization.
期刊最新文献
[Focus on and response to climate-sensitive diseases]. [Expert consensus on the passive immunization prevention of infant respiratory syncytial virus infection in China]. [Advances in the application of liquid chromatography tandem mass spectrometry for therapeutic drug monitoring]. [Analysis of pollution status and influencing factors of polybrominated diphenyl ethers in household dust in five cities in northern China]. [Analysis of the changes of bacterial spectrum and drug resistance in sputum culture of ICU children in a hospital of pediatric in Jiangsu Province from 2017 to 2022].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1