Latif Zafar Jilani, Yasir Salam Siddiqui, Abdul Qayyum Khan, Mohammad Istiyak
{"title":"自体无血管腓骨加压钢板治疗无菌性复杂长骨不愈合。","authors":"Latif Zafar Jilani, Yasir Salam Siddiqui, Abdul Qayyum Khan, Mohammad Istiyak","doi":"10.62347/DQLS6083","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The surgical treatment of non-union of long bones are challenging especially when bones are osteoporotic or there is a large bone gap due to repeated surgeries and implant failures. Plate with intramedullary fibula provides a stable construct as fibula acts as a second implant with better anchorage and high pull-out strength. The aim of our study is to present our experience of treating complex non-union of long bones using compression plating (LCP<sub>s</sub>/DCP<sub>s</sub>) in combination with autologous non-vascularized fibular graft (ANVFG).</p><p><strong>Material and methods: </strong>10 cases of complex non-union of long bones (tibia, femur, humerus) treated with debridement, decortication followed by intramedullary fibular strut grafting and rigid osteosynthesis by LCP<sub>s</sub>/DCP<sub>s</sub> were included in this study. DASH score and LEFS score was used for upper limb and lower limb functional assessment.</p><p><strong>Results: </strong>All patients had clinico-radiological union with a mean time of 11.4 months. Pre-operative mean DASH and LEFS score was 45.9±2.1 and 20.6±2.03 At the last follow-up, mean DASH and LEFS score was 19.8±1.1 and 60.6±2.6.</p><p><strong>Conclusion: </strong>Compression plating with ANVFG is a viable option for treating complex non-union of long bones. Intramedullary fibula acting as a second implant provides mechanical stability and support biological healing with its osteogenic property at the non-union site.</p>","PeriodicalId":45488,"journal":{"name":"International Journal of Burns and Trauma","volume":"14 4","pages":"75-83"},"PeriodicalIF":1.4000,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11411171/pdf/","citationCount":"0","resultStr":"{\"title\":\"Autologous non-vascularized fibula with compression plating in the management of aseptic complex non-union of long bones.\",\"authors\":\"Latif Zafar Jilani, Yasir Salam Siddiqui, Abdul Qayyum Khan, Mohammad Istiyak\",\"doi\":\"10.62347/DQLS6083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The surgical treatment of non-union of long bones are challenging especially when bones are osteoporotic or there is a large bone gap due to repeated surgeries and implant failures. Plate with intramedullary fibula provides a stable construct as fibula acts as a second implant with better anchorage and high pull-out strength. The aim of our study is to present our experience of treating complex non-union of long bones using compression plating (LCP<sub>s</sub>/DCP<sub>s</sub>) in combination with autologous non-vascularized fibular graft (ANVFG).</p><p><strong>Material and methods: </strong>10 cases of complex non-union of long bones (tibia, femur, humerus) treated with debridement, decortication followed by intramedullary fibular strut grafting and rigid osteosynthesis by LCP<sub>s</sub>/DCP<sub>s</sub> were included in this study. DASH score and LEFS score was used for upper limb and lower limb functional assessment.</p><p><strong>Results: </strong>All patients had clinico-radiological union with a mean time of 11.4 months. Pre-operative mean DASH and LEFS score was 45.9±2.1 and 20.6±2.03 At the last follow-up, mean DASH and LEFS score was 19.8±1.1 and 60.6±2.6.</p><p><strong>Conclusion: </strong>Compression plating with ANVFG is a viable option for treating complex non-union of long bones. Intramedullary fibula acting as a second implant provides mechanical stability and support biological healing with its osteogenic property at the non-union site.</p>\",\"PeriodicalId\":45488,\"journal\":{\"name\":\"International Journal of Burns and Trauma\",\"volume\":\"14 4\",\"pages\":\"75-83\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11411171/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Burns and Trauma\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.62347/DQLS6083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Burns and Trauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.62347/DQLS6083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
Autologous non-vascularized fibula with compression plating in the management of aseptic complex non-union of long bones.
Background: The surgical treatment of non-union of long bones are challenging especially when bones are osteoporotic or there is a large bone gap due to repeated surgeries and implant failures. Plate with intramedullary fibula provides a stable construct as fibula acts as a second implant with better anchorage and high pull-out strength. The aim of our study is to present our experience of treating complex non-union of long bones using compression plating (LCPs/DCPs) in combination with autologous non-vascularized fibular graft (ANVFG).
Material and methods: 10 cases of complex non-union of long bones (tibia, femur, humerus) treated with debridement, decortication followed by intramedullary fibular strut grafting and rigid osteosynthesis by LCPs/DCPs were included in this study. DASH score and LEFS score was used for upper limb and lower limb functional assessment.
Results: All patients had clinico-radiological union with a mean time of 11.4 months. Pre-operative mean DASH and LEFS score was 45.9±2.1 and 20.6±2.03 At the last follow-up, mean DASH and LEFS score was 19.8±1.1 and 60.6±2.6.
Conclusion: Compression plating with ANVFG is a viable option for treating complex non-union of long bones. Intramedullary fibula acting as a second implant provides mechanical stability and support biological healing with its osteogenic property at the non-union site.