将椎骨质量评分作为腰骶部融合手术患者骨质疏松症诊断的新工具:一项单中心队列研究。

IF 1.8 Q3 MEDICINE, RESEARCH & EXPERIMENTAL European Journal of Translational Myology Pub Date : 2024-09-16 DOI:10.4081/ejtm.2024.12311
Arvin Najafi, Ali Baradaran Bagheri, Dorsa Hadavi, Aidin Mobedi, Salman Azarsina, Pouria Chaghamirzayi
{"title":"将椎骨质量评分作为腰骶部融合手术患者骨质疏松症诊断的新工具:一项单中心队列研究。","authors":"Arvin Najafi, Ali Baradaran Bagheri, Dorsa Hadavi, Aidin Mobedi, Salman Azarsina, Pouria Chaghamirzayi","doi":"10.4081/ejtm.2024.12311","DOIUrl":null,"url":null,"abstract":"<p><p>Osteoporosis, a common bone disorder, increases fracture and spinal surgery complications risk. This study evaluates the potential of the Magnetic Resonance Imaging (MRI)-based Vertebral Bone Quality (VBQ) score as an alternative for assessing bone density in lumbosacral fusion surgery patients. In a prospective cohort study from April 2021 to November 2022, 134 patients with lumbar degenerative diseases underwent lumbar Dual-Energy X-ray Absorptiometry (DXA) and lumbosacral non-contrast T1-weighted MRI. VBQ scores were calculated and analyzed using IBM SPSS Statistics and MedCalc software. Osteopenia/Osteoporosis patients exhibited significantly higher VBQ scores than normal bone mineral density patients (3.37 ± 0.51 vs. 2.99 ± 0.44, P<0.001). VBQ correlated significantly with lumbar DXA T scores (r value= -0.415, p<0.001). Receiver Operating Characteristic (ROC) analysis showed VBQ AUC values of 0.730 (CI 95% 0.647-0.803, P<0.001) and 0.839 (CI 95% 0.765-0.897, P<0.001) for Osteopenia/Osteoporosis and osteoporosis diagnosis, respectively. The study suggests MRI-derived VBQ scores may benefit pre-lumbosacral fusion surgery bone density assessment, potentially improving patient care and aiding osteoporosis detection in spinal surgery candidates.</p>","PeriodicalId":46459,"journal":{"name":"European Journal of Translational Myology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11726176/pdf/","citationCount":"0","resultStr":"{\"title\":\"Vertebral bone quality score as a new tool for osteoporosis diagnosis in patients undergoing lumbosacral fusion surgery: a single center cohort study.\",\"authors\":\"Arvin Najafi, Ali Baradaran Bagheri, Dorsa Hadavi, Aidin Mobedi, Salman Azarsina, Pouria Chaghamirzayi\",\"doi\":\"10.4081/ejtm.2024.12311\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Osteoporosis, a common bone disorder, increases fracture and spinal surgery complications risk. This study evaluates the potential of the Magnetic Resonance Imaging (MRI)-based Vertebral Bone Quality (VBQ) score as an alternative for assessing bone density in lumbosacral fusion surgery patients. In a prospective cohort study from April 2021 to November 2022, 134 patients with lumbar degenerative diseases underwent lumbar Dual-Energy X-ray Absorptiometry (DXA) and lumbosacral non-contrast T1-weighted MRI. VBQ scores were calculated and analyzed using IBM SPSS Statistics and MedCalc software. Osteopenia/Osteoporosis patients exhibited significantly higher VBQ scores than normal bone mineral density patients (3.37 ± 0.51 vs. 2.99 ± 0.44, P<0.001). VBQ correlated significantly with lumbar DXA T scores (r value= -0.415, p<0.001). Receiver Operating Characteristic (ROC) analysis showed VBQ AUC values of 0.730 (CI 95% 0.647-0.803, P<0.001) and 0.839 (CI 95% 0.765-0.897, P<0.001) for Osteopenia/Osteoporosis and osteoporosis diagnosis, respectively. The study suggests MRI-derived VBQ scores may benefit pre-lumbosacral fusion surgery bone density assessment, potentially improving patient care and aiding osteoporosis detection in spinal surgery candidates.</p>\",\"PeriodicalId\":46459,\"journal\":{\"name\":\"European Journal of Translational Myology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11726176/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Translational Myology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/ejtm.2024.12311\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Translational Myology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ejtm.2024.12311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

骨质疏松症是一种常见的骨科疾病,会增加骨折和脊柱手术并发症的风险。本研究评估了基于磁共振成像(MRI)的椎骨质量(VBQ)评分作为腰骶椎融合手术患者骨密度评估替代方法的潜力。在 2021 年 4 月至 2022 年 11 月的一项前瞻性队列研究中,134 名腰椎退行性疾病患者接受了腰椎双能量 X 射线吸收测定(DXA)和腰骶部非对比 T1 加权磁共振成像检查。使用 IBM SPSS 统计软件和 MedCalc 软件计算和分析 VBQ 分数。骨质疏松症/骨质疏松症患者的 VBQ 分数明显高于骨矿密度正常的患者(3.37 ± 0.51 vs. 2.99 ± 0.44,P<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Vertebral bone quality score as a new tool for osteoporosis diagnosis in patients undergoing lumbosacral fusion surgery: a single center cohort study.

Osteoporosis, a common bone disorder, increases fracture and spinal surgery complications risk. This study evaluates the potential of the Magnetic Resonance Imaging (MRI)-based Vertebral Bone Quality (VBQ) score as an alternative for assessing bone density in lumbosacral fusion surgery patients. In a prospective cohort study from April 2021 to November 2022, 134 patients with lumbar degenerative diseases underwent lumbar Dual-Energy X-ray Absorptiometry (DXA) and lumbosacral non-contrast T1-weighted MRI. VBQ scores were calculated and analyzed using IBM SPSS Statistics and MedCalc software. Osteopenia/Osteoporosis patients exhibited significantly higher VBQ scores than normal bone mineral density patients (3.37 ± 0.51 vs. 2.99 ± 0.44, P<0.001). VBQ correlated significantly with lumbar DXA T scores (r value= -0.415, p<0.001). Receiver Operating Characteristic (ROC) analysis showed VBQ AUC values of 0.730 (CI 95% 0.647-0.803, P<0.001) and 0.839 (CI 95% 0.765-0.897, P<0.001) for Osteopenia/Osteoporosis and osteoporosis diagnosis, respectively. The study suggests MRI-derived VBQ scores may benefit pre-lumbosacral fusion surgery bone density assessment, potentially improving patient care and aiding osteoporosis detection in spinal surgery candidates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Translational Myology
European Journal of Translational Myology MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
3.30
自引率
27.30%
发文量
74
审稿时长
10 weeks
期刊最新文献
Ejtm3 experiences after ChatGPT and other AI approaches: values, risks, countermeasures. Evaluation of efficacy and safety of generic tacrolimus (Suprotac®) compared to reference tacrolimus (Prograf®) in kidney transplantation: a phase IV study. New horizons for adolescent idiopathic scoliosis treatment through PosturalSpine® D'Amanti Method. Oxy-inflammation in hyperbaric oxygen therapy applications. A neurophysiological and genetic assessment of a case of rapidly progressive scoliosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1