遗传性视网膜疾病患者的角膜生物力学变化

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2024-09-19 eCollection Date: 2024-01-01 DOI:10.2147/OPTH.S478846
Ana Marta, André Ferreira, Inês Couto, Miguel Mesquita Neves, Miguel Gomes, Luis Oliveira, Celia Azevedo Soares, Maria João Menéres, Carolina Lemos, João Melo Beirão
{"title":"遗传性视网膜疾病患者的角膜生物力学变化","authors":"Ana Marta, André Ferreira, Inês Couto, Miguel Mesquita Neves, Miguel Gomes, Luis Oliveira, Celia Azevedo Soares, Maria João Menéres, Carolina Lemos, João Melo Beirão","doi":"10.2147/OPTH.S478846","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Inherited retinal diseases (IRDs) are a group of degenerative disorders of the retina, that can be potentially associated with changes in the anterior segment, but their prevalence and impact are not known. Exploring these concomitant ophthalmologic changes with biomechanical assessment may help identify other non-retina causes of vision loss in these patients, such as corneal ectasia or susceptibility to glaucoma. This study aimed to measure and compare corneal biomechanics in patients with and without IRDs.</p><p><strong>Methods: </strong>A total of 77 patients (154 eyes) with IRD were recruited as the study group. The control group consisted of 77 healthy adults (154 eyes) with matched age and sphere equivalents. All participants underwent a comprehensive assessment including corneal tomography (Pentacam<sup>®</sup>) and biomechanical assessment (Corvis ST<sup>®</sup>). A total of 4 second-generation biomechanical parameters and 3 indexes were collected: Ambrosio Relational Thickness (ARTh), Deflection Amplitude Ratio Max (DARM), Integrated Radius (IR) and Stiffness Parameter at Applanation (SP-A1), the final deviation value D of the Belin/Ambrosio Enhanced Ectasia Display (BAD-D), Corvis Biomechanical Index (CBI) and Tomographic Biomechanical Index (TBI).</p><p><strong>Results: </strong>For IRD patients, there was a higher DARM (p < 0.001), lower ARTh (p < 0.001), higher CBI (p < 0.001), higher TBI (p<0.001), and higher BAD-D (p < 0.001) compared to the control group. Regarding discrimination of healthy subjects and IRD patients, ARTh was the most sensitive parameter.</p><p><strong>Conclusion: </strong>The results showed that IRD patients tend to have softer corneal behaviour, compared to eyes without pathology, which may predispose patients to corneal ectasia or glaucoma development. ARTh could be used to screen IRD patients if a non-retina cause of vision loss is suspected.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11420929/pdf/","citationCount":"0","resultStr":"{\"title\":\"Corneal Biomechanical Changes in Patients with Inherited Retinal Diseases.\",\"authors\":\"Ana Marta, André Ferreira, Inês Couto, Miguel Mesquita Neves, Miguel Gomes, Luis Oliveira, Celia Azevedo Soares, Maria João Menéres, Carolina Lemos, João Melo Beirão\",\"doi\":\"10.2147/OPTH.S478846\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Inherited retinal diseases (IRDs) are a group of degenerative disorders of the retina, that can be potentially associated with changes in the anterior segment, but their prevalence and impact are not known. Exploring these concomitant ophthalmologic changes with biomechanical assessment may help identify other non-retina causes of vision loss in these patients, such as corneal ectasia or susceptibility to glaucoma. This study aimed to measure and compare corneal biomechanics in patients with and without IRDs.</p><p><strong>Methods: </strong>A total of 77 patients (154 eyes) with IRD were recruited as the study group. The control group consisted of 77 healthy adults (154 eyes) with matched age and sphere equivalents. All participants underwent a comprehensive assessment including corneal tomography (Pentacam<sup>®</sup>) and biomechanical assessment (Corvis ST<sup>®</sup>). A total of 4 second-generation biomechanical parameters and 3 indexes were collected: Ambrosio Relational Thickness (ARTh), Deflection Amplitude Ratio Max (DARM), Integrated Radius (IR) and Stiffness Parameter at Applanation (SP-A1), the final deviation value D of the Belin/Ambrosio Enhanced Ectasia Display (BAD-D), Corvis Biomechanical Index (CBI) and Tomographic Biomechanical Index (TBI).</p><p><strong>Results: </strong>For IRD patients, there was a higher DARM (p < 0.001), lower ARTh (p < 0.001), higher CBI (p < 0.001), higher TBI (p<0.001), and higher BAD-D (p < 0.001) compared to the control group. Regarding discrimination of healthy subjects and IRD patients, ARTh was the most sensitive parameter.</p><p><strong>Conclusion: </strong>The results showed that IRD patients tend to have softer corneal behaviour, compared to eyes without pathology, which may predispose patients to corneal ectasia or glaucoma development. ARTh could be used to screen IRD patients if a non-retina cause of vision loss is suspected.</p>\",\"PeriodicalId\":93945,\"journal\":{\"name\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11420929/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTH.S478846\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S478846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:遗传性视网膜疾病(IRD)是一组视网膜退行性疾病,可能与眼前节的变化有关,但其发病率和影响尚不清楚。通过生物力学评估来探究这些伴随的眼科变化,可能有助于确定导致这些患者视力下降的其他非视网膜原因,如角膜异位症或青光眼易感性。本研究旨在测量和比较IRD患者和非IRD患者的角膜生物力学:研究组共招募了 77 名 IRD 患者(154 只眼睛)。对照组由 77 名健康成年人(154 只眼睛)组成,他们的年龄和眼球等值相匹配。所有参与者都接受了全面的评估,包括角膜断层扫描(Pentacam®)和生物力学评估(Corvis ST®)。共收集了 4 项第二代生物力学参数和 3 项指数:安布罗西奥相关厚度(ARTh)、偏转振幅比最大值(DARM)、综合半径(IR)和斜视时的刚度参数(SP-A1)、贝林/安布罗西奥增强外翻显示(BAD-D)的最终偏差值D、Corvis生物力学指数(CBI)和断层扫描生物力学指数(TBI):结果:IRD 患者的 DARM 较高(p < 0.001)、ARTh 较低(p < 0.001)、CBI 较高(p < 0.001)、TBI 较高(p结果表明,与无病变的眼睛相比,IRD 患者的角膜表现更软,这可能会导致患者角膜异位或青光眼的发生。如果怀疑视力下降的原因与视网膜无关,可使用 ARTh 对 IRD 患者进行筛查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Corneal Biomechanical Changes in Patients with Inherited Retinal Diseases.

Purpose: Inherited retinal diseases (IRDs) are a group of degenerative disorders of the retina, that can be potentially associated with changes in the anterior segment, but their prevalence and impact are not known. Exploring these concomitant ophthalmologic changes with biomechanical assessment may help identify other non-retina causes of vision loss in these patients, such as corneal ectasia or susceptibility to glaucoma. This study aimed to measure and compare corneal biomechanics in patients with and without IRDs.

Methods: A total of 77 patients (154 eyes) with IRD were recruited as the study group. The control group consisted of 77 healthy adults (154 eyes) with matched age and sphere equivalents. All participants underwent a comprehensive assessment including corneal tomography (Pentacam®) and biomechanical assessment (Corvis ST®). A total of 4 second-generation biomechanical parameters and 3 indexes were collected: Ambrosio Relational Thickness (ARTh), Deflection Amplitude Ratio Max (DARM), Integrated Radius (IR) and Stiffness Parameter at Applanation (SP-A1), the final deviation value D of the Belin/Ambrosio Enhanced Ectasia Display (BAD-D), Corvis Biomechanical Index (CBI) and Tomographic Biomechanical Index (TBI).

Results: For IRD patients, there was a higher DARM (p < 0.001), lower ARTh (p < 0.001), higher CBI (p < 0.001), higher TBI (p<0.001), and higher BAD-D (p < 0.001) compared to the control group. Regarding discrimination of healthy subjects and IRD patients, ARTh was the most sensitive parameter.

Conclusion: The results showed that IRD patients tend to have softer corneal behaviour, compared to eyes without pathology, which may predispose patients to corneal ectasia or glaucoma development. ARTh could be used to screen IRD patients if a non-retina cause of vision loss is suspected.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
期刊最新文献
Association Between Particulate Matter Pollutants and Ophthalmology Visits for Ocular Surface Irritation and Allergy. The Cutting Efficiency of a Hybrid Phacoemulsification Tip Using High and Low Intraocular Pressure Settings in Different Grades of Cataract. Comparison of Large Language Models in Diagnosis and Management of Challenging Clinical Cases. Enhancing OCT Reliability: The Role of Eye-Tracking in Achieving Consistent Retinal Measurements [Letter]. Baseline Characteristics and Clinical Outcomes of Patients Seen Through the Free Diabetes Screening (FDS) Program.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1