用于米兰达驴血液学分析的两种护理点测定的分析验证

IF 2 2区 农林科学 Q2 VETERINARY SCIENCES Veterinary Sciences Pub Date : 2024-09-22 DOI:10.3390/vetsci11090450
Céline Costa, Ana Patrícia Sousa, Grasiene Silva, Felisbina Queiroga, Ângela Martins, Daniela Andrade, Ana C Silvestre-Ferreira
{"title":"用于米兰达驴血液学分析的两种护理点测定的分析验证","authors":"Céline Costa, Ana Patrícia Sousa, Grasiene Silva, Felisbina Queiroga, Ângela Martins, Daniela Andrade, Ana C Silvestre-Ferreira","doi":"10.3390/vetsci11090450","DOIUrl":null,"url":null,"abstract":"<p><p>Miranda donkeys are an endangered autochthonous breed of Portugal. The HemoCue WBC DIFF and HemoCue Hb 201 portable analyzers, developed as a simplified alternative method for total and differential WBC count and hemoglobin measurement, respectively, may be relevant tools in veterinary practice. This study aimed to validate these instruments using Miranda donkey blood samples. For the HemoCue WBC DIFF, most parameters showed acceptable intra- and inter-assay precision with coefficients of variation (CV) below 5%, except for monocytes and eosinophils with higher CVs. The HemoCue Hb 201 showed CVs of 1.98% and 4.07%. Linearity correlation coefficients (r) ranged from 0.53 to 0.99 for HemoCue WBC DIFF and 0.99 for HemoCue Hb 201. Significant levels for neutrophils, lymphocytes, monocytes, eosinophils, and Hb measurements varied. Comparisons with ProCyte Dx showed an excellent correlation for WBC (r<sub>s</sub> = 0.96), neutrophils (r<sub>s</sub> = 0.91), lymphocytes (r<sub>s</sub> = 0.94), and eosinophils (r<sub>s</sub> = 0.90) but a poor correlation for monocytes and basophils. The HemoCue Hb 201 showed a correlation of r<sub>s</sub> = 0.96 with ProCyte Dx. In conclusion, both analyzers provided reliable results and are suitable for use in Miranda's donkey breed for WBC counts and Hb measurements.</p>","PeriodicalId":23694,"journal":{"name":"Veterinary Sciences","volume":"11 9","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11435812/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analytical Validation of Two Point-of-Care Assays for Hematological Analysis in the Miranda Donkey.\",\"authors\":\"Céline Costa, Ana Patrícia Sousa, Grasiene Silva, Felisbina Queiroga, Ângela Martins, Daniela Andrade, Ana C Silvestre-Ferreira\",\"doi\":\"10.3390/vetsci11090450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Miranda donkeys are an endangered autochthonous breed of Portugal. The HemoCue WBC DIFF and HemoCue Hb 201 portable analyzers, developed as a simplified alternative method for total and differential WBC count and hemoglobin measurement, respectively, may be relevant tools in veterinary practice. This study aimed to validate these instruments using Miranda donkey blood samples. For the HemoCue WBC DIFF, most parameters showed acceptable intra- and inter-assay precision with coefficients of variation (CV) below 5%, except for monocytes and eosinophils with higher CVs. The HemoCue Hb 201 showed CVs of 1.98% and 4.07%. Linearity correlation coefficients (r) ranged from 0.53 to 0.99 for HemoCue WBC DIFF and 0.99 for HemoCue Hb 201. Significant levels for neutrophils, lymphocytes, monocytes, eosinophils, and Hb measurements varied. Comparisons with ProCyte Dx showed an excellent correlation for WBC (r<sub>s</sub> = 0.96), neutrophils (r<sub>s</sub> = 0.91), lymphocytes (r<sub>s</sub> = 0.94), and eosinophils (r<sub>s</sub> = 0.90) but a poor correlation for monocytes and basophils. The HemoCue Hb 201 showed a correlation of r<sub>s</sub> = 0.96 with ProCyte Dx. In conclusion, both analyzers provided reliable results and are suitable for use in Miranda's donkey breed for WBC counts and Hb measurements.</p>\",\"PeriodicalId\":23694,\"journal\":{\"name\":\"Veterinary Sciences\",\"volume\":\"11 9\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11435812/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Sciences\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3390/vetsci11090450\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Sciences","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3390/vetsci11090450","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

米兰达驴是葡萄牙濒临灭绝的本土品种。HemoCue WBC DIFF 和 HemoCue Hb 201 便携式分析仪是分别作为白细胞总数和差值以及血红蛋白测量的简化替代方法而开发的,可能是兽医实践中的相关工具。本研究旨在使用米兰达驴血样验证这些仪器。除了单核细胞和嗜酸性粒细胞的变异系数(CV)较高外,HemoCue WBC DIFF 的大多数参数显示出可接受的测定内和测定间精度,变异系数(CV)低于 5%。HemoCue Hb 201 的变异系数分别为 1.98% 和 4.07%。HemoCue WBC DIFF 的线性相关系数 (r) 为 0.53 至 0.99,HemoCue Hb 201 为 0.99。中性粒细胞、淋巴细胞、单核细胞、嗜酸性粒细胞和 Hb 测量的显著水平各不相同。与 ProCyte Dx 的比较显示,白细胞(rs = 0.96)、中性粒细胞(rs = 0.91)、淋巴细胞(rs = 0.94)和嗜酸性粒细胞(rs = 0.90)的相关性极佳,但单核细胞和嗜碱性粒细胞的相关性较差。HemoCue Hb 201 与 ProCyte Dx 的相关性为 rs = 0.96。总之,这两种分析仪都能提供可靠的结果,适用于米兰达驴种的白细胞计数和血红蛋白测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analytical Validation of Two Point-of-Care Assays for Hematological Analysis in the Miranda Donkey.

Miranda donkeys are an endangered autochthonous breed of Portugal. The HemoCue WBC DIFF and HemoCue Hb 201 portable analyzers, developed as a simplified alternative method for total and differential WBC count and hemoglobin measurement, respectively, may be relevant tools in veterinary practice. This study aimed to validate these instruments using Miranda donkey blood samples. For the HemoCue WBC DIFF, most parameters showed acceptable intra- and inter-assay precision with coefficients of variation (CV) below 5%, except for monocytes and eosinophils with higher CVs. The HemoCue Hb 201 showed CVs of 1.98% and 4.07%. Linearity correlation coefficients (r) ranged from 0.53 to 0.99 for HemoCue WBC DIFF and 0.99 for HemoCue Hb 201. Significant levels for neutrophils, lymphocytes, monocytes, eosinophils, and Hb measurements varied. Comparisons with ProCyte Dx showed an excellent correlation for WBC (rs = 0.96), neutrophils (rs = 0.91), lymphocytes (rs = 0.94), and eosinophils (rs = 0.90) but a poor correlation for monocytes and basophils. The HemoCue Hb 201 showed a correlation of rs = 0.96 with ProCyte Dx. In conclusion, both analyzers provided reliable results and are suitable for use in Miranda's donkey breed for WBC counts and Hb measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary Sciences
Veterinary Sciences VETERINARY SCIENCES-
CiteScore
2.90
自引率
8.30%
发文量
612
审稿时长
6 weeks
期刊介绍: Veterinary Sciences is an international and interdisciplinary scholarly open access journal. It publishes original that are relevant to any field of veterinary sciences, including prevention, diagnosis and treatment of disease, disorder and injury in animals. This journal covers almost all topics related to animal health and veterinary medicine. Research fields of interest include but are not limited to: anaesthesiology anatomy bacteriology biochemistry cardiology dentistry dermatology embryology endocrinology epidemiology genetics histology immunology microbiology molecular biology mycology neurobiology oncology ophthalmology parasitology pathology pharmacology physiology radiology surgery theriogenology toxicology virology.
期刊最新文献
B-Flow and Contrast-Enhanced Ultrasound (CEUS) Features of Subcutaneous Masses and Nodular Lesions in Dogs. In Situ Expression of Yak IL-22 in Mammary Glands as a Treatment for Bovine Staphylococcus aureus-Induced Mastitis in Mice. Electroencephalographic and Cardiovascular Assessments of Isoflurane-Anesthetized Dogs. Early Detection of Lumpy Skin Disease in Cattle Using Deep Learning-A Comparative Analysis of Pretrained Models. Effect of Using Prickly Pear Seed Cake (Opuntia ficus indica L.) on Growth Performance, Digestibility, Physiological and Histometric Parameters in Rabbits.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1