二茂铁连接的新型硫氨酸作为电化学检测多巴胺和过氧化氢的双重氧化还原介质

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL Biosensors-Basel Pub Date : 2024-09-19 DOI:10.3390/bios14090448
Manikandan Palinci Nagarajan, Manikandan Ramalingam, Ilakeya Subbiah Arivuthilagam, Vishwa Paramaguru, Md Mahbubur Rahman, Jongdeok Park, Francis Kwaku Asiam, Byungjik Lee, Kwang Pyo Kim, Jae-Joon Lee
{"title":"二茂铁连接的新型硫氨酸作为电化学检测多巴胺和过氧化氢的双重氧化还原介质","authors":"Manikandan Palinci Nagarajan, Manikandan Ramalingam, Ilakeya Subbiah Arivuthilagam, Vishwa Paramaguru, Md Mahbubur Rahman, Jongdeok Park, Francis Kwaku Asiam, Byungjik Lee, Kwang Pyo Kim, Jae-Joon Lee","doi":"10.3390/bios14090448","DOIUrl":null,"url":null,"abstract":"<p><p>We introduce a novel dual redox mediator synthesized by covalently linking ferrocene dicarboxylic acid (FcDA) and thionine (TH) onto a pre-treated glassy carbon electrode. This unique structure significantly enhances the electro-oxidation of dopamine (DA) and the reduction of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), offering a sensitive detection method for both analytes. The electrode exhibits exceptional sensitivity, selectivity, and stability, demonstrating potential for practical applications in biosensing. It facilitates rapid electron transfer between the analyte and the electrode surface, detecting H<sub>2</sub>O<sub>2</sub> concentrations ranging from 1.5 to 60 µM with a limit of detection (LoD) of 0.49 µM and DA concentrations from 0.3 to 230 µM with an LoD of 0.07 µM. The electrode's performance was validated through real-sample analyses, yielding satisfactory results.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 9","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11429643/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Novel Ferrocene-Linked Thionine as a Dual Redox Mediator for the Electrochemical Detection of Dopamine and Hydrogen Peroxide.\",\"authors\":\"Manikandan Palinci Nagarajan, Manikandan Ramalingam, Ilakeya Subbiah Arivuthilagam, Vishwa Paramaguru, Md Mahbubur Rahman, Jongdeok Park, Francis Kwaku Asiam, Byungjik Lee, Kwang Pyo Kim, Jae-Joon Lee\",\"doi\":\"10.3390/bios14090448\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We introduce a novel dual redox mediator synthesized by covalently linking ferrocene dicarboxylic acid (FcDA) and thionine (TH) onto a pre-treated glassy carbon electrode. This unique structure significantly enhances the electro-oxidation of dopamine (DA) and the reduction of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), offering a sensitive detection method for both analytes. The electrode exhibits exceptional sensitivity, selectivity, and stability, demonstrating potential for practical applications in biosensing. It facilitates rapid electron transfer between the analyte and the electrode surface, detecting H<sub>2</sub>O<sub>2</sub> concentrations ranging from 1.5 to 60 µM with a limit of detection (LoD) of 0.49 µM and DA concentrations from 0.3 to 230 µM with an LoD of 0.07 µM. The electrode's performance was validated through real-sample analyses, yielding satisfactory results.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"14 9\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11429643/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios14090448\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14090448","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们介绍了一种新型双重氧化还原介质,它是通过将二茂铁二羧酸(FcDA)和亚硫酸(TH)共价连接到预先处理过的玻璃碳电极上而合成的。这种独特的结构大大增强了多巴胺(DA)的电氧化作用和过氧化氢(H2O2)的还原作用,为这两种分析物提供了一种灵敏的检测方法。该电极具有极高的灵敏度、选择性和稳定性,显示了在生物传感领域的实际应用潜力。它能促进分析物与电极表面之间的快速电子转移,检测 H2O2 浓度范围为 1.5 至 60 µM,检测限(LoD)为 0.49 µM;检测 DA 浓度范围为 0.3 至 230 µM,检测限(LoD)为 0.07 µM。通过实际样品分析验证了该电极的性能,结果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel Ferrocene-Linked Thionine as a Dual Redox Mediator for the Electrochemical Detection of Dopamine and Hydrogen Peroxide.

We introduce a novel dual redox mediator synthesized by covalently linking ferrocene dicarboxylic acid (FcDA) and thionine (TH) onto a pre-treated glassy carbon electrode. This unique structure significantly enhances the electro-oxidation of dopamine (DA) and the reduction of hydrogen peroxide (H2O2), offering a sensitive detection method for both analytes. The electrode exhibits exceptional sensitivity, selectivity, and stability, demonstrating potential for practical applications in biosensing. It facilitates rapid electron transfer between the analyte and the electrode surface, detecting H2O2 concentrations ranging from 1.5 to 60 µM with a limit of detection (LoD) of 0.49 µM and DA concentrations from 0.3 to 230 µM with an LoD of 0.07 µM. The electrode's performance was validated through real-sample analyses, yielding satisfactory results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
期刊最新文献
Ru@UiO-66-NH2 MOFs-Based Dual Emission Ratiometric Fluorescence for Sensitive Sensing of Arginine. Source Localization and Classification of Pulmonary Valve-Originated Electrocardiograms Using Volume Conductor Modeling with Anatomical Models. Prediction of Thrombus Formation within an Oxygenator via Bioimpedance Analysis. Electrochemical Analysis of Amyloid Plaques and ApoE4 with Chitosan-Coated Gold Nanostars for Alzheimer's Detection. Enhancing Target Detection: A Fluorescence-Based Streptavidin-Bead Displacement Assay.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1