Bozhou Zhuang , Bora Gencturk , Anton Sinkov , Morris Good , Ryan Meyer , Assad Oberai
{"title":"用非侵入式超声波探测部分全尺寸乏核燃料罐模型的内部状况","authors":"Bozhou Zhuang , Bora Gencturk , Anton Sinkov , Morris Good , Ryan Meyer , Assad Oberai","doi":"10.1016/j.ndteint.2024.103242","DOIUrl":null,"url":null,"abstract":"<div><div>The safe storage of spent nuclear fuel (SNF) in dry cask storage systems (DCSSs) is critical to the nuclear fuel cycle and the future of nuclear energy. A critical component of DCSSs is the SNF canister. The canister is a sealed stainless-steel structure, which is first vacuum dried and then backfilled with helium. The structural deterioration within a canister can be monitored through its internal gas properties. This monitoring serves as the driving force behind the non-invasive ultrasonic sensing approach in this paper. A major challenge in collecting gas-borne signals using ultrasonic sensing is the impedance mismatch between the stainless-steel canister and the helium gas inside. Only a small fraction of the ultrasonic signal makes its way from the transmitter to the receiver through the gas medium. In this paper, experimental studies on a partial full-scale canister mock-up were carried out to capture the gas-borne signals. Damping materials were applied on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The research results showed that the excitation frequency played an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight (TOF) at 225 kHz. A high signal-to-noise ratio (SNR) was achieved in the measurements. Next, acoustic impedance matching (AIM) layers were added, and it was found that the gas signal energy was improved by 160.4% compared with that of no AIM layers. Subsequently, the relative humidity (RH) level and temperature of the gas were varied to simulate abnormal internal conditions of the canister. The non-invasive testing system demonstrated reliability and sensitivity in detecting gas temperature and RH variations. Theoretical calculations demonstrated the potential for detecting low-level xenon and air within an actual SNF canister filled with helium. Last, an active noise cancellation (ANC) method, previously developed by the authors, was verified on the canister mock-up for the first time. The results showed that the SNR of the gas signal was improved by 213.6% compared with that of no ANC.</div></div>","PeriodicalId":18868,"journal":{"name":"Ndt & E International","volume":"148 ","pages":"Article 103242"},"PeriodicalIF":4.1000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non-invasive ultrasonic sensing of internal conditions on a partial full-scale spent nuclear fuel canister mock-up\",\"authors\":\"Bozhou Zhuang , Bora Gencturk , Anton Sinkov , Morris Good , Ryan Meyer , Assad Oberai\",\"doi\":\"10.1016/j.ndteint.2024.103242\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The safe storage of spent nuclear fuel (SNF) in dry cask storage systems (DCSSs) is critical to the nuclear fuel cycle and the future of nuclear energy. A critical component of DCSSs is the SNF canister. The canister is a sealed stainless-steel structure, which is first vacuum dried and then backfilled with helium. The structural deterioration within a canister can be monitored through its internal gas properties. This monitoring serves as the driving force behind the non-invasive ultrasonic sensing approach in this paper. A major challenge in collecting gas-borne signals using ultrasonic sensing is the impedance mismatch between the stainless-steel canister and the helium gas inside. Only a small fraction of the ultrasonic signal makes its way from the transmitter to the receiver through the gas medium. In this paper, experimental studies on a partial full-scale canister mock-up were carried out to capture the gas-borne signals. Damping materials were applied on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The research results showed that the excitation frequency played an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight (TOF) at 225 kHz. A high signal-to-noise ratio (SNR) was achieved in the measurements. Next, acoustic impedance matching (AIM) layers were added, and it was found that the gas signal energy was improved by 160.4% compared with that of no AIM layers. Subsequently, the relative humidity (RH) level and temperature of the gas were varied to simulate abnormal internal conditions of the canister. The non-invasive testing system demonstrated reliability and sensitivity in detecting gas temperature and RH variations. Theoretical calculations demonstrated the potential for detecting low-level xenon and air within an actual SNF canister filled with helium. Last, an active noise cancellation (ANC) method, previously developed by the authors, was verified on the canister mock-up for the first time. The results showed that the SNR of the gas signal was improved by 213.6% compared with that of no ANC.</div></div>\",\"PeriodicalId\":18868,\"journal\":{\"name\":\"Ndt & E International\",\"volume\":\"148 \",\"pages\":\"Article 103242\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ndt & E International\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S096386952400207X\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ndt & E International","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S096386952400207X","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
Non-invasive ultrasonic sensing of internal conditions on a partial full-scale spent nuclear fuel canister mock-up
The safe storage of spent nuclear fuel (SNF) in dry cask storage systems (DCSSs) is critical to the nuclear fuel cycle and the future of nuclear energy. A critical component of DCSSs is the SNF canister. The canister is a sealed stainless-steel structure, which is first vacuum dried and then backfilled with helium. The structural deterioration within a canister can be monitored through its internal gas properties. This monitoring serves as the driving force behind the non-invasive ultrasonic sensing approach in this paper. A major challenge in collecting gas-borne signals using ultrasonic sensing is the impedance mismatch between the stainless-steel canister and the helium gas inside. Only a small fraction of the ultrasonic signal makes its way from the transmitter to the receiver through the gas medium. In this paper, experimental studies on a partial full-scale canister mock-up were carried out to capture the gas-borne signals. Damping materials were applied on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The research results showed that the excitation frequency played an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight (TOF) at 225 kHz. A high signal-to-noise ratio (SNR) was achieved in the measurements. Next, acoustic impedance matching (AIM) layers were added, and it was found that the gas signal energy was improved by 160.4% compared with that of no AIM layers. Subsequently, the relative humidity (RH) level and temperature of the gas were varied to simulate abnormal internal conditions of the canister. The non-invasive testing system demonstrated reliability and sensitivity in detecting gas temperature and RH variations. Theoretical calculations demonstrated the potential for detecting low-level xenon and air within an actual SNF canister filled with helium. Last, an active noise cancellation (ANC) method, previously developed by the authors, was verified on the canister mock-up for the first time. The results showed that the SNR of the gas signal was improved by 213.6% compared with that of no ANC.
期刊介绍:
NDT&E international publishes peer-reviewed results of original research and development in all categories of the fields of nondestructive testing and evaluation including ultrasonics, electromagnetics, radiography, optical and thermal methods. In addition to traditional NDE topics, the emerging technology area of inspection of civil structures and materials is also emphasized. The journal publishes original papers on research and development of new inspection techniques and methods, as well as on novel and innovative applications of established methods. Papers on NDE sensors and their applications both for inspection and process control, as well as papers describing novel NDE systems for structural health monitoring and their performance in industrial settings are also considered. Other regular features include international news, new equipment and a calendar of forthcoming worldwide meetings. This journal is listed in Current Contents.