B-018 设计和开发即用型塑料管式 MASTM 糖尿病 Max 控制装置

IF 7.1 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Clinical chemistry Pub Date : 2024-10-02 DOI:10.1093/clinchem/hvae106.382
M Nagaraj, D Crandall, M Kasprisin, N Adams, J Shah, A Qureshi, R Hu
{"title":"B-018 设计和开发即用型塑料管式 MASTM 糖尿病 Max 控制装置","authors":"M Nagaraj, D Crandall, M Kasprisin, N Adams, J Shah, A Qureshi, R Hu","doi":"10.1093/clinchem/hvae106.382","DOIUrl":null,"url":null,"abstract":"Background The Thermo Scientific™ MAS™ Controls are assayed controls to monitor assay performance within clinical laboratory settings. The user can compare observed results of controls with their expected ranges as a means of assuring consistent performance of both reagent and instrument. The objective of developing MAS™ Ready-to-Use Tube Controls is to provide MAS™ controls in a new automation-friendly plastic tube format, as an alternative to the current glass vials. Diabetes Max Control is the first MAS™ product designed and developed in this ready-to-use format to be placed directly on the analyzer. The new format will increase efficiency and allow for on-board refrigerated storage, and it is expected to reduce material loss and contamination. It contains Hemoglobin A1c formulated in whole blood matrix to mimic patient specimens. In this presentation we summarize the Feasibility, Development, Verification, and Validation results of MAS™ Diabetes Max Controls. Methods The performance was assessed by conducting the following studies for MAS™ Diabetes Max Tube Controls. The analyte Hemoglobin A1c was measured in functional studies to evaluate and verify the product performance. Other studies were also designed and performed to assess the product usability. Results MAS™ Diabetes Max Control results demonstrated comparable performance and Fit/Form/Function criterion on specified platforms, particularly the TOSOH™ platform. All feasibility studies provided very promising results passing per protocol criterion. Design Verification and Validation studies ensured product integrity and passed specifications for proposed claims. Process Validation is in progress with data being collected for both Value Assignments and Real Time Stability. Conclusions MAS™ Diabetes Max Controls provided in ready-to-use tubes met the design specification criteria. We believe that MAS™ Diabetes Max Controls will contribute to the increased efficiency of core lab workflow by allowing the analyzer(s) to aspirate controls directly from the tube and allow for control storage in an on-board refrigeration unit.","PeriodicalId":10690,"journal":{"name":"Clinical chemistry","volume":"220 1","pages":""},"PeriodicalIF":7.1000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"B-018 Design and Development of MASTM Diabetes Max Controls, Ready-to-Use Plastic Tube Format\",\"authors\":\"M Nagaraj, D Crandall, M Kasprisin, N Adams, J Shah, A Qureshi, R Hu\",\"doi\":\"10.1093/clinchem/hvae106.382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background The Thermo Scientific™ MAS™ Controls are assayed controls to monitor assay performance within clinical laboratory settings. The user can compare observed results of controls with their expected ranges as a means of assuring consistent performance of both reagent and instrument. The objective of developing MAS™ Ready-to-Use Tube Controls is to provide MAS™ controls in a new automation-friendly plastic tube format, as an alternative to the current glass vials. Diabetes Max Control is the first MAS™ product designed and developed in this ready-to-use format to be placed directly on the analyzer. The new format will increase efficiency and allow for on-board refrigerated storage, and it is expected to reduce material loss and contamination. It contains Hemoglobin A1c formulated in whole blood matrix to mimic patient specimens. In this presentation we summarize the Feasibility, Development, Verification, and Validation results of MAS™ Diabetes Max Controls. Methods The performance was assessed by conducting the following studies for MAS™ Diabetes Max Tube Controls. The analyte Hemoglobin A1c was measured in functional studies to evaluate and verify the product performance. Other studies were also designed and performed to assess the product usability. Results MAS™ Diabetes Max Control results demonstrated comparable performance and Fit/Form/Function criterion on specified platforms, particularly the TOSOH™ platform. All feasibility studies provided very promising results passing per protocol criterion. Design Verification and Validation studies ensured product integrity and passed specifications for proposed claims. Process Validation is in progress with data being collected for both Value Assignments and Real Time Stability. Conclusions MAS™ Diabetes Max Controls provided in ready-to-use tubes met the design specification criteria. We believe that MAS™ Diabetes Max Controls will contribute to the increased efficiency of core lab workflow by allowing the analyzer(s) to aspirate controls directly from the tube and allow for control storage in an on-board refrigeration unit.\",\"PeriodicalId\":10690,\"journal\":{\"name\":\"Clinical chemistry\",\"volume\":\"220 1\",\"pages\":\"\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/clinchem/hvae106.382\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/clinchem/hvae106.382","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景 Thermo Scientific™ MAS™ 对照品是用于监测临床实验室化验性能的化验对照品。用户可以将观察到的对照结果与其预期范围进行比较,从而确保试剂和仪器的性能保持一致。开发 MAS™ 即用试管对照品的目的是以一种新的自动化友好型塑料试管形式提供 MAS™ 对照品,以替代目前的玻璃瓶。Diabetes Max Control 是首款以这种即用型形式设计开发的 MAS™ 产品,可直接放置在分析仪上。这种新的格式将提高效率,允许机载冷藏储存,并有望减少材料损耗和污染。它包含在全血基质中配制的血红蛋白 A1c,以模拟病人标本。在本报告中,我们总结了 MAS™ Diabetes Max Controls 的可行性、开发、验证和确认结果。方法 通过对 MAS™ Diabetes Max 管对照进行以下研究来评估其性能。在功能研究中测量分析物血红蛋白 A1c,以评估和验证产品性能。还设计并进行了其他研究,以评估产品的可用性。结果 MAS™ Diabetes Max Control 在特定平台上,尤其是 TOSOH™ 平台上,表现出可比的性能和合身性/外形/功能标准。所有可行性研究都提供了非常有前景的结果,符合协议标准。设计验证和确认研究确保了产品的完整性,并通过了建议索赔的规格要求。工艺验证正在进行中,正在收集值分配和实时稳定性数据。结论 即用型试管中的 MAS™ Diabetes Max Controls 符合设计规范标准。我们相信,MAS™ Diabetes Max Controls 将有助于提高核心实验室工作流程的效率,因为它允许分析仪直接从试管中抽吸对照品,并允许将对照品储存在机载冷藏装置中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
B-018 Design and Development of MASTM Diabetes Max Controls, Ready-to-Use Plastic Tube Format
Background The Thermo Scientific™ MAS™ Controls are assayed controls to monitor assay performance within clinical laboratory settings. The user can compare observed results of controls with their expected ranges as a means of assuring consistent performance of both reagent and instrument. The objective of developing MAS™ Ready-to-Use Tube Controls is to provide MAS™ controls in a new automation-friendly plastic tube format, as an alternative to the current glass vials. Diabetes Max Control is the first MAS™ product designed and developed in this ready-to-use format to be placed directly on the analyzer. The new format will increase efficiency and allow for on-board refrigerated storage, and it is expected to reduce material loss and contamination. It contains Hemoglobin A1c formulated in whole blood matrix to mimic patient specimens. In this presentation we summarize the Feasibility, Development, Verification, and Validation results of MAS™ Diabetes Max Controls. Methods The performance was assessed by conducting the following studies for MAS™ Diabetes Max Tube Controls. The analyte Hemoglobin A1c was measured in functional studies to evaluate and verify the product performance. Other studies were also designed and performed to assess the product usability. Results MAS™ Diabetes Max Control results demonstrated comparable performance and Fit/Form/Function criterion on specified platforms, particularly the TOSOH™ platform. All feasibility studies provided very promising results passing per protocol criterion. Design Verification and Validation studies ensured product integrity and passed specifications for proposed claims. Process Validation is in progress with data being collected for both Value Assignments and Real Time Stability. Conclusions MAS™ Diabetes Max Controls provided in ready-to-use tubes met the design specification criteria. We believe that MAS™ Diabetes Max Controls will contribute to the increased efficiency of core lab workflow by allowing the analyzer(s) to aspirate controls directly from the tube and allow for control storage in an on-board refrigeration unit.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry
Clinical chemistry 医学-医学实验技术
CiteScore
11.30
自引率
4.30%
发文量
212
审稿时长
1.7 months
期刊介绍: Clinical Chemistry is a peer-reviewed scientific journal that is the premier publication for the science and practice of clinical laboratory medicine. It was established in 1955 and is associated with the Association for Diagnostics & Laboratory Medicine (ADLM). The journal focuses on laboratory diagnosis and management of patients, and has expanded to include other clinical laboratory disciplines such as genomics, hematology, microbiology, and toxicology. It also publishes articles relevant to clinical specialties including cardiology, endocrinology, gastroenterology, genetics, immunology, infectious diseases, maternal-fetal medicine, neurology, nutrition, oncology, and pediatrics. In addition to original research, editorials, and reviews, Clinical Chemistry features recurring sections such as clinical case studies, perspectives, podcasts, and Q&A articles. It has the highest impact factor among journals of clinical chemistry, laboratory medicine, pathology, analytical chemistry, transfusion medicine, and clinical microbiology. The journal is indexed in databases such as MEDLINE and Web of Science.
期刊最新文献
Virtual Gene Panels Have a Superior Diagnostic Yield for Inherited Rare Diseases Relative to Static Panels Xylazine Pharmacokinetics in Patients Testing Positive for Fentanyl and Xylazine. Prospective and External Validation of an Ensemble Learning Approach to Sensitively Detect Intravenous Fluid Contamination in Basic Metabolic Panels Niacin and Risk of Cardiovascular Events: Deciphering the Paradox. Alzheimer Disease Blood-Based Biomarkers: Translation from Research into Clinical Use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1