正确使用他克莫司。

IF 2.8 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Therapeutic Drug Monitoring Pub Date : 2024-10-02 DOI:10.1097/FTD.0000000000001266
Pierre Marquet
{"title":"正确使用他克莫司。","authors":"Pierre Marquet","doi":"10.1097/FTD.0000000000001266","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Tacrolimus (TAC) dosing is typically guided by the trough concentration (C0). Yet, significant relationships between TAC C0 and clinical outcomes have seldom been reported or only with adverse events. Large retrospective studies found a moderate correlation between TAC C0 and the area under the curve (AUC), where, for any given C0 value, the AUC varied 3- to 4-fold between patients (and vice versa). However, no randomized controlled trial evaluating the dose adjustment based on TAC AUC has been conducted yet. A few observational studies have shown that the AUC is associated with efficacy and, to a lesser extent, adverse effects. Other studies showed the feasibility of reaching predefined target ranges and reducing underexposure and overexposure. TAC AUC0-12 h is now most often assessed using Bayesian estimation, but machine learning is a promising approach. Microsampling devices are well accepted by patients and represent a valuable alternative to venous blood sample collection during hospital visits, especially when a limited sampling strategy is required. As AUC monitoring cannot be proposed very frequently, C0 monitoring has to be used in the interim, which has led to fluctuating doses in patients with an AUC/C0 ratio far from the population mean, because of different dose recommendations between the 2 biomarkers. We proposed estimating the individual AUC/C0 ratio and derived individual C0 targets to be used in between or as a replacement for AUC monitoring. Existing technology and evidence are now sufficient to propose AUC monitoring interspersed with individualized-C0 monitoring for all patients with kidney transplants while collecting real-world data to strengthen the evidence.</p>","PeriodicalId":23052,"journal":{"name":"Therapeutic Drug Monitoring","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Getting Tacrolimus Dosing Right.\",\"authors\":\"Pierre Marquet\",\"doi\":\"10.1097/FTD.0000000000001266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>Tacrolimus (TAC) dosing is typically guided by the trough concentration (C0). Yet, significant relationships between TAC C0 and clinical outcomes have seldom been reported or only with adverse events. Large retrospective studies found a moderate correlation between TAC C0 and the area under the curve (AUC), where, for any given C0 value, the AUC varied 3- to 4-fold between patients (and vice versa). However, no randomized controlled trial evaluating the dose adjustment based on TAC AUC has been conducted yet. A few observational studies have shown that the AUC is associated with efficacy and, to a lesser extent, adverse effects. Other studies showed the feasibility of reaching predefined target ranges and reducing underexposure and overexposure. TAC AUC0-12 h is now most often assessed using Bayesian estimation, but machine learning is a promising approach. Microsampling devices are well accepted by patients and represent a valuable alternative to venous blood sample collection during hospital visits, especially when a limited sampling strategy is required. As AUC monitoring cannot be proposed very frequently, C0 monitoring has to be used in the interim, which has led to fluctuating doses in patients with an AUC/C0 ratio far from the population mean, because of different dose recommendations between the 2 biomarkers. We proposed estimating the individual AUC/C0 ratio and derived individual C0 targets to be used in between or as a replacement for AUC monitoring. Existing technology and evidence are now sufficient to propose AUC monitoring interspersed with individualized-C0 monitoring for all patients with kidney transplants while collecting real-world data to strengthen the evidence.</p>\",\"PeriodicalId\":23052,\"journal\":{\"name\":\"Therapeutic Drug Monitoring\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Drug Monitoring\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/FTD.0000000000001266\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Drug Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/FTD.0000000000001266","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

摘要:他克莫司(TAC)的剂量通常以谷浓度(C0)为指导。然而,TAC C0 与临床结果之间的重要关系却鲜有报道,或仅与不良反应有关。大型回顾性研究发现,TAC C0 与曲线下面积(AUC)之间存在中度相关性,对于任何给定的 C0 值,患者之间的 AUC 差异为 3-4 倍(反之亦然)。然而,目前还没有随机对照试验对基于 TAC AUC 的剂量调整进行评估。一些观察性研究表明,AUC 与疗效有关,其次与不良反应有关。其他研究表明,达到预定目标范围并减少暴露不足和暴露过度是可行的。目前,TAC AUC0-12 h 的评估多采用贝叶斯估计法,但机器学习也是一种很有前途的方法。微采样装置已被患者广泛接受,是医院就诊时静脉血样本采集的重要替代方法,尤其是在需要有限采样策略的情况下。由于 AUC 监测的频率不高,在此期间必须使用 C0 监测,这就导致了患者的剂量波动,AUC/C0 比值与人群平均值相差甚远,因为这两种生物标记物的剂量建议不同。我们建议估算个体的 AUC/C0 比值并推导出个体的 C0 目标值,在两者之间使用或替代 AUC 监测。现有的技术和证据已足以建议在对所有肾移植患者进行 AUC 监测的同时进行个体化 C0 监测,同时收集真实世界的数据以加强证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Getting Tacrolimus Dosing Right.

Abstract: Tacrolimus (TAC) dosing is typically guided by the trough concentration (C0). Yet, significant relationships between TAC C0 and clinical outcomes have seldom been reported or only with adverse events. Large retrospective studies found a moderate correlation between TAC C0 and the area under the curve (AUC), where, for any given C0 value, the AUC varied 3- to 4-fold between patients (and vice versa). However, no randomized controlled trial evaluating the dose adjustment based on TAC AUC has been conducted yet. A few observational studies have shown that the AUC is associated with efficacy and, to a lesser extent, adverse effects. Other studies showed the feasibility of reaching predefined target ranges and reducing underexposure and overexposure. TAC AUC0-12 h is now most often assessed using Bayesian estimation, but machine learning is a promising approach. Microsampling devices are well accepted by patients and represent a valuable alternative to venous blood sample collection during hospital visits, especially when a limited sampling strategy is required. As AUC monitoring cannot be proposed very frequently, C0 monitoring has to be used in the interim, which has led to fluctuating doses in patients with an AUC/C0 ratio far from the population mean, because of different dose recommendations between the 2 biomarkers. We proposed estimating the individual AUC/C0 ratio and derived individual C0 targets to be used in between or as a replacement for AUC monitoring. Existing technology and evidence are now sufficient to propose AUC monitoring interspersed with individualized-C0 monitoring for all patients with kidney transplants while collecting real-world data to strengthen the evidence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutic Drug Monitoring
Therapeutic Drug Monitoring 医学-毒理学
CiteScore
5.00
自引率
8.00%
发文量
213
审稿时长
4-8 weeks
期刊介绍: Therapeutic Drug Monitoring is a peer-reviewed, multidisciplinary journal directed to an audience of pharmacologists, clinical chemists, laboratorians, pharmacists, drug researchers and toxicologists. It fosters the exchange of knowledge among the various disciplines–clinical pharmacology, pathology, toxicology, analytical chemistry–that share a common interest in Therapeutic Drug Monitoring. The journal presents studies detailing the various factors that affect the rate and extent drugs are absorbed, metabolized, and excreted. Regular features include review articles on specific classes of drugs, original articles, case reports, technical notes, and continuing education articles.
期刊最新文献
Serum Concentration of Antidepressant Drugs in Geriatric Day Care Patients With Renal Insufficiency and Multimorbidity. Alternate Sampling Matrices for Therapeutic Drug Monitoring of Immunosuppressants. Midazolam Boosting With Cobicistat in a Patient With Drug-Resistant Epilepsy and Focal Status Epilepticus. New Developments and Therapeutic Drug Monitoring Options in Costimulatory Blockade in Solid Organ Transplantation: A Systematic Critical Review. Implementation of Volumetric Finger-Prick Self-Sampling for TDM of Immunosuppressants After Kidney Transplantation: Lessons Learned from the Practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1