Elena Martínez-Plaza, Alberto López-de la Rosa, Ainhoa Molina-Martín, Laurent Bataille, David P Piñero
{"title":"轴向长度与角膜巩膜矢状高度和巩膜不对称的关系。","authors":"Elena Martínez-Plaza, Alberto López-de la Rosa, Ainhoa Molina-Martín, Laurent Bataille, David P Piñero","doi":"10.1111/opo.13402","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine how corneoscleral geometry changes with axial length and to assess the usefulness of including the sagittal configuration of the anterior segment when predicting the axial length.</p><p><strong>Methods: </strong>An observational study was performed including 96 healthy subjects (96 eyes). Axial length was calculated from optical biometry (IOL Master 500). Corneal curvature and scleral sagittal height parameters at 13, 14 and 15 mm were obtained automatically using corneoscleral topography (eye surface profiler; ESP). In addition, corneal and scleral sagittal heights at numerous locations (21 radii: 0-10 mm from the corneal apex at 12 angles: 0-330°) were calculated using the raw height data extracted from the ESP. The relationships between axial length and the study parameters were analysed using Pearson correlation analysis. The equations for the prediction of axial length were obtained by fitting multiple linear regression models.</p><p><strong>Results: </strong>The temporal-nasal scleral asymmetry at 13-, 14- and 15-mm chord lengths was significantly correlated with axial length (r<sup>2</sup> ≤ 0.26; p < 0.001). Significant inverse correlations were found between the temporal scleral sagittal height and axial length (r<sup>2</sup> ≤ 0.28; p ≤ 0.02). The nasal scleral sagittal height was not associated with axial length. Three significant multiple linear regression models were fitted based on spherical equivalent, corneal radius and scleral asymmetry at 13 (r<sup>2</sup> = 0.79; p < 0.001), 14 (r<sup>2</sup> = 0.80; p < 0.001) and 15 (r<sup>2</sup> = 0.80; p < 0.001) mm chord lengths.</p><p><strong>Conclusions: </strong>Larger ocular globes show reduced temporal-nasal scleral asymmetry, mainly due to the lower sagittal height of the temporal sclera. Thus, the geometry of the temporal scleral may be a factor of interest during myopia progression.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Axial length association with corneoscleral sagittal height and scleral asymmetry.\",\"authors\":\"Elena Martínez-Plaza, Alberto López-de la Rosa, Ainhoa Molina-Martín, Laurent Bataille, David P Piñero\",\"doi\":\"10.1111/opo.13402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine how corneoscleral geometry changes with axial length and to assess the usefulness of including the sagittal configuration of the anterior segment when predicting the axial length.</p><p><strong>Methods: </strong>An observational study was performed including 96 healthy subjects (96 eyes). Axial length was calculated from optical biometry (IOL Master 500). Corneal curvature and scleral sagittal height parameters at 13, 14 and 15 mm were obtained automatically using corneoscleral topography (eye surface profiler; ESP). In addition, corneal and scleral sagittal heights at numerous locations (21 radii: 0-10 mm from the corneal apex at 12 angles: 0-330°) were calculated using the raw height data extracted from the ESP. The relationships between axial length and the study parameters were analysed using Pearson correlation analysis. The equations for the prediction of axial length were obtained by fitting multiple linear regression models.</p><p><strong>Results: </strong>The temporal-nasal scleral asymmetry at 13-, 14- and 15-mm chord lengths was significantly correlated with axial length (r<sup>2</sup> ≤ 0.26; p < 0.001). Significant inverse correlations were found between the temporal scleral sagittal height and axial length (r<sup>2</sup> ≤ 0.28; p ≤ 0.02). The nasal scleral sagittal height was not associated with axial length. Three significant multiple linear regression models were fitted based on spherical equivalent, corneal radius and scleral asymmetry at 13 (r<sup>2</sup> = 0.79; p < 0.001), 14 (r<sup>2</sup> = 0.80; p < 0.001) and 15 (r<sup>2</sup> = 0.80; p < 0.001) mm chord lengths.</p><p><strong>Conclusions: </strong>Larger ocular globes show reduced temporal-nasal scleral asymmetry, mainly due to the lower sagittal height of the temporal sclera. Thus, the geometry of the temporal scleral may be a factor of interest during myopia progression.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13402\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13402","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Axial length association with corneoscleral sagittal height and scleral asymmetry.
Purpose: To determine how corneoscleral geometry changes with axial length and to assess the usefulness of including the sagittal configuration of the anterior segment when predicting the axial length.
Methods: An observational study was performed including 96 healthy subjects (96 eyes). Axial length was calculated from optical biometry (IOL Master 500). Corneal curvature and scleral sagittal height parameters at 13, 14 and 15 mm were obtained automatically using corneoscleral topography (eye surface profiler; ESP). In addition, corneal and scleral sagittal heights at numerous locations (21 radii: 0-10 mm from the corneal apex at 12 angles: 0-330°) were calculated using the raw height data extracted from the ESP. The relationships between axial length and the study parameters were analysed using Pearson correlation analysis. The equations for the prediction of axial length were obtained by fitting multiple linear regression models.
Results: The temporal-nasal scleral asymmetry at 13-, 14- and 15-mm chord lengths was significantly correlated with axial length (r2 ≤ 0.26; p < 0.001). Significant inverse correlations were found between the temporal scleral sagittal height and axial length (r2 ≤ 0.28; p ≤ 0.02). The nasal scleral sagittal height was not associated with axial length. Three significant multiple linear regression models were fitted based on spherical equivalent, corneal radius and scleral asymmetry at 13 (r2 = 0.79; p < 0.001), 14 (r2 = 0.80; p < 0.001) and 15 (r2 = 0.80; p < 0.001) mm chord lengths.
Conclusions: Larger ocular globes show reduced temporal-nasal scleral asymmetry, mainly due to the lower sagittal height of the temporal sclera. Thus, the geometry of the temporal scleral may be a factor of interest during myopia progression.
期刊介绍:
Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry.
OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.