基于新型 Ti3C2Tx/Co-BDC 气体传感器的化学电阻式三乙胺检测器

IF 8 1区 化学 Q1 CHEMISTRY, ANALYTICAL Sensors and Actuators B: Chemical Pub Date : 2024-10-04 DOI:10.1016/j.snb.2024.136738
Huan Liu, Qingcai Chen, Tengfei Xu, Heng Liu, Lei Miao, Wenhao Liu, Jingwen Cheng, Shu Yin, Chuanyi Wang, Jincai Zhao
{"title":"基于新型 Ti3C2Tx/Co-BDC 气体传感器的化学电阻式三乙胺检测器","authors":"Huan Liu, Qingcai Chen, Tengfei Xu, Heng Liu, Lei Miao, Wenhao Liu, Jingwen Cheng, Shu Yin, Chuanyi Wang, Jincai Zhao","doi":"10.1016/j.snb.2024.136738","DOIUrl":null,"url":null,"abstract":"Triethylamine (TEA), a representative volatile organic environmental pollutant, poses significant environmental pollution risks and can adversely affect the liver and nervous system, potentially leading to fatal outcomes. However, existing gas sensors for TEA detection have pressing drawbacks, such as safety hazards associated with high-temperature operation and poor timeliness due to time-consuming testing. Herein, the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>/Co-BDC sensor demonstrates ultra-sensitive detection of TEA at a low temperature of 100 °C. This temperature is below the threshold for explosion-proof operation, ensuring safe application in flammable and explosive environments. Meanwhile, the introduction of the metal-like MXene with ultra-high conductivity accelerates the response and recovery process (11<!-- --> <!-- -->s/20<!-- --> <!-- -->s), facilitating highly efficient TEA detection within a sub-minute timeframe. The Ti-O-Co interfacial bonds between Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> and Co-BDC, confirmed by both XPS analysis and theoretical calculations, enhance carrier mobility across the two materials, significantly boosting gas-sensing performance. The rapid detection of TEA at low temperatures makes the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>/Co-BDC sensor more suitable for practical environmental monitoring in flammable and explosive areas, further contributing to human health and production safety.","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":null,"pages":null},"PeriodicalIF":8.0000,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chemiresistive triethylamine detection based on the novel Ti3C2Tx/Co-BDC gas sensor\",\"authors\":\"Huan Liu, Qingcai Chen, Tengfei Xu, Heng Liu, Lei Miao, Wenhao Liu, Jingwen Cheng, Shu Yin, Chuanyi Wang, Jincai Zhao\",\"doi\":\"10.1016/j.snb.2024.136738\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Triethylamine (TEA), a representative volatile organic environmental pollutant, poses significant environmental pollution risks and can adversely affect the liver and nervous system, potentially leading to fatal outcomes. However, existing gas sensors for TEA detection have pressing drawbacks, such as safety hazards associated with high-temperature operation and poor timeliness due to time-consuming testing. Herein, the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>/Co-BDC sensor demonstrates ultra-sensitive detection of TEA at a low temperature of 100 °C. This temperature is below the threshold for explosion-proof operation, ensuring safe application in flammable and explosive environments. Meanwhile, the introduction of the metal-like MXene with ultra-high conductivity accelerates the response and recovery process (11<!-- --> <!-- -->s/20<!-- --> <!-- -->s), facilitating highly efficient TEA detection within a sub-minute timeframe. The Ti-O-Co interfacial bonds between Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> and Co-BDC, confirmed by both XPS analysis and theoretical calculations, enhance carrier mobility across the two materials, significantly boosting gas-sensing performance. The rapid detection of TEA at low temperatures makes the Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>/Co-BDC sensor more suitable for practical environmental monitoring in flammable and explosive areas, further contributing to human health and production safety.\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.snb.2024.136738\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.snb.2024.136738","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

三乙胺(TEA)是一种具有代表性的挥发性有机环境污染物,会对环境造成严重的污染风险,并对肝脏和神经系统产生不利影响,有可能导致致命后果。然而,现有的三乙胺检测气体传感器存在一些亟待解决的问题,如高温操作带来的安全隐患以及耗时测试导致的时效性差等。在此,Ti3C2Tx/Co-BDC 传感器展示了在 100 °C 低温下对三乙醇胺的超灵敏检测。该温度低于防爆操作阈值,确保了在易燃易爆环境中的安全应用。同时,具有超高传导性的类金属 MXene 的引入加快了响应和恢复过程(11 秒/20 秒),有助于在一分钟以内实现高效的三乙醇胺检测。经 XPS 分析和理论计算证实,Ti3C2Tx 和 Co-BDC 之间的 Ti-O-Co 界面键增强了两种材料之间的载流子迁移率,从而显著提高了气体传感性能。在低温下快速检测 TEA 使 Ti3C2Tx/Co-BDC 传感器更适用于易燃易爆区域的实际环境监测,从而进一步促进人类健康和生产安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Chemiresistive triethylamine detection based on the novel Ti3C2Tx/Co-BDC gas sensor
Triethylamine (TEA), a representative volatile organic environmental pollutant, poses significant environmental pollution risks and can adversely affect the liver and nervous system, potentially leading to fatal outcomes. However, existing gas sensors for TEA detection have pressing drawbacks, such as safety hazards associated with high-temperature operation and poor timeliness due to time-consuming testing. Herein, the Ti3C2Tx/Co-BDC sensor demonstrates ultra-sensitive detection of TEA at a low temperature of 100 °C. This temperature is below the threshold for explosion-proof operation, ensuring safe application in flammable and explosive environments. Meanwhile, the introduction of the metal-like MXene with ultra-high conductivity accelerates the response and recovery process (11 s/20 s), facilitating highly efficient TEA detection within a sub-minute timeframe. The Ti-O-Co interfacial bonds between Ti3C2Tx and Co-BDC, confirmed by both XPS analysis and theoretical calculations, enhance carrier mobility across the two materials, significantly boosting gas-sensing performance. The rapid detection of TEA at low temperatures makes the Ti3C2Tx/Co-BDC sensor more suitable for practical environmental monitoring in flammable and explosive areas, further contributing to human health and production safety.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
期刊最新文献
Advanced design of indented-standing surface acoustic wave (i-SSAW) device for platelet-derived microparticle separation from whole blood Machine learning-aided quantitative detection of two mixed antibiotics in a narrow concentration range based on oxygen incorporation-induced 3D SERS substrates Exploration of Glyoxals’ Level Changes in Endoplasmic Reticulum during Ferroptosis by a Photocaged Fluorescent Probe Superluminescent Variants of Gaussia Luciferase in Living Animal Deep-tissue Imaging Cell membrane-inspired COF/AAO hybrid nanofluidic membrane with ion current rectification properties for ultrasensitive detection of E. coli
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1