{"title":"评估用于前臼齿修复的基于智能色度技术的复合树脂的配色能力","authors":"Kamyar Fathpour, Alaleh Salehi, Pouran Samimi, Amirhossein Fathi","doi":"10.1155/2024/5514821","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> This study aims to evaluate the color-matching ability of OMNICHROMA composite, a single-shade composite, using the CIE L <sup><i>∗</i></sup> a <sup><i>∗</i></sup> b <sup><i>∗</i></sup> system and determining <i>Δ</i>E values. <b>Materials and Methods:</b> In this in vitro study, 30 intact premolar teeth were collected, cleaned, and disinfected with 0.5% thymol solution. The teeth were stored in distilled water at 37°C. A putty index calibrated the color assessment sites on buccal and lingual surfaces. Two cavities were prepared, one with 1.25 mm depth (enamel) and another with 2.25 mm depth (dentin), and restored using OMNICHROMA composite resin. The putty index measured the color of the cured composite, and <i>Δ</i>E between the composite and original tooth color was calculated. <b>Statistical analysis:</b> Data analysis included <i>t</i>-tests, correlation coefficients, and Fisher's exact test (<i>α</i> = 0.05). <b>Results:</b> The mean <i>Δ</i>E was 2.39 in enamel cavities and 2.32 in dentin cavities, both within the clinically acceptable range (<3.3). In enamel cavities, the composite color was darker than the tooth, shifting toward green and blue shades. In dentin cavities, the composite color was lighter than the tooth, with shifts toward green and yellow shades. Color matching was slightly better in dentin cavities, but the difference was not statistically significant (<i>p</i>=0.719). <b>Conclusion:</b> OMNICHROMA composite resin's color matching falls within the clinically acceptable range, unaffected by cavity depth.</p>","PeriodicalId":13947,"journal":{"name":"International Journal of Dentistry","volume":"2024 ","pages":"5514821"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11452232/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluating the Color Matching Ability of a Smart Chromatic Technology-Based Composite Resin for Premolar Teeth Restoration.\",\"authors\":\"Kamyar Fathpour, Alaleh Salehi, Pouran Samimi, Amirhossein Fathi\",\"doi\":\"10.1155/2024/5514821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> This study aims to evaluate the color-matching ability of OMNICHROMA composite, a single-shade composite, using the CIE L <sup><i>∗</i></sup> a <sup><i>∗</i></sup> b <sup><i>∗</i></sup> system and determining <i>Δ</i>E values. <b>Materials and Methods:</b> In this in vitro study, 30 intact premolar teeth were collected, cleaned, and disinfected with 0.5% thymol solution. The teeth were stored in distilled water at 37°C. A putty index calibrated the color assessment sites on buccal and lingual surfaces. Two cavities were prepared, one with 1.25 mm depth (enamel) and another with 2.25 mm depth (dentin), and restored using OMNICHROMA composite resin. The putty index measured the color of the cured composite, and <i>Δ</i>E between the composite and original tooth color was calculated. <b>Statistical analysis:</b> Data analysis included <i>t</i>-tests, correlation coefficients, and Fisher's exact test (<i>α</i> = 0.05). <b>Results:</b> The mean <i>Δ</i>E was 2.39 in enamel cavities and 2.32 in dentin cavities, both within the clinically acceptable range (<3.3). In enamel cavities, the composite color was darker than the tooth, shifting toward green and blue shades. In dentin cavities, the composite color was lighter than the tooth, with shifts toward green and yellow shades. Color matching was slightly better in dentin cavities, but the difference was not statistically significant (<i>p</i>=0.719). <b>Conclusion:</b> OMNICHROMA composite resin's color matching falls within the clinically acceptable range, unaffected by cavity depth.</p>\",\"PeriodicalId\":13947,\"journal\":{\"name\":\"International Journal of Dentistry\",\"volume\":\"2024 \",\"pages\":\"5514821\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11452232/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/5514821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/5514821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在使用 CIE L ∗ a ∗ b ∗ 系统评估 OMNICHROMA 复合材料(一种单一色调的复合材料)的配色能力,并确定 ΔE 值。材料和方法:在这项体外研究中,收集了 30 颗完整的前臼齿,用 0.5% 百里酚溶液清洗和消毒。牙齿储存在 37°C 的蒸馏水中。用油灰指数校准颊面和舌面的颜色评估点。制备了两个龋洞,一个深度为 1.25 毫米(釉质),另一个深度为 2.25 毫米(牙本质),并使用 OMNICHROMA 复合树脂进行修复。腻子指数测量了固化复合树脂的颜色,并计算了复合树脂与原牙颜色之间的ΔE。统计分析:数据分析包括 t 检验、相关系数和费雪精确检验(α = 0.05)。结果釉质龋洞的平均ΔE 为 2.39,牙本质龋洞的平均ΔE 为 2.32,均在临床可接受范围内(P=0.719)。结论:OMNICHROMAOMNICHROMA 复合树脂的颜色匹配度在临床可接受范围内,不受龋洞深度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating the Color Matching Ability of a Smart Chromatic Technology-Based Composite Resin for Premolar Teeth Restoration.

Objectives: This study aims to evaluate the color-matching ability of OMNICHROMA composite, a single-shade composite, using the CIE L a b system and determining ΔE values. Materials and Methods: In this in vitro study, 30 intact premolar teeth were collected, cleaned, and disinfected with 0.5% thymol solution. The teeth were stored in distilled water at 37°C. A putty index calibrated the color assessment sites on buccal and lingual surfaces. Two cavities were prepared, one with 1.25 mm depth (enamel) and another with 2.25 mm depth (dentin), and restored using OMNICHROMA composite resin. The putty index measured the color of the cured composite, and ΔE between the composite and original tooth color was calculated. Statistical analysis: Data analysis included t-tests, correlation coefficients, and Fisher's exact test (α = 0.05). Results: The mean ΔE was 2.39 in enamel cavities and 2.32 in dentin cavities, both within the clinically acceptable range (<3.3). In enamel cavities, the composite color was darker than the tooth, shifting toward green and blue shades. In dentin cavities, the composite color was lighter than the tooth, with shifts toward green and yellow shades. Color matching was slightly better in dentin cavities, but the difference was not statistically significant (p=0.719). Conclusion: OMNICHROMA composite resin's color matching falls within the clinically acceptable range, unaffected by cavity depth.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Dentistry
International Journal of Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
4.80%
发文量
219
审稿时长
20 weeks
期刊最新文献
Prevalence and Severity of Sleep Bruxism in Edentulous Patients: A Cross-Sectional Study. Elementary Teacher's Perception of Oral Health Education in a City of the Brazilian Amazon: A Cross-Sectional Study. Comparison of Internal and Marginal Adaptation of Endocrowns at Different Depths Fabricated by the Digital and Conventional Impression Techniques: Internal and Marginal Fit of Endocrowns. Push-Out Bond Strength of Fiber-Reinforced Post Using Various Post Space Irrigation Treatments. Comparison of Histological, Clinical, and Radiographic Outcomes of Postextraction Ridge Preservation by Allogenic Bone Grafting With and Without Injectable Platelet-Rich Fibrin: A Double-Blinded Randomized Controlled Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1