Sravanthy Busi, P J Nagarathna, Anushka Deoghare, Keyura Parakh, Rashmi S Lokhande, Swati Malladi
{"title":"使用锥形束计算机断层扫描分析评估和比较 Pro AF Baby Gold 和 Pedoflex 锉在初级根管中的牙本质厚度、居中能力、根管运输和器械操作时间:体外研究","authors":"Sravanthy Busi, P J Nagarathna, Anushka Deoghare, Keyura Parakh, Rashmi S Lokhande, Swati Malladi","doi":"10.5005/jp-journals-10005-2929","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Pediatric rotary systems have the advantage of improved canal centricity and conservative canal preparation with better obturation quality. Pro AF Baby Gold and Pedoflex files are two exclusive pediatric rotary file systems that were introduced in recent times.</p><p><strong>Aim and objective: </strong>The aim of the present study is to compare and evaluate the dentine thickness, centering ability, canal transportation, and instrumentation time of Pro AF Baby Gold and Pedoflex files using cone beam computed tomography (CBCT).</p><p><strong>Materials and methods: </strong>A total of 40 extracted human primary molar teeth with a minimum 7 mm root length were included in the study and randomly divided into two groups: group I, Pro AF Baby Gold; group II, Pedoflex files. Teeth were imaged preoperatively with CBCT, then root canal preparation was done in both groups with respective files, followed by postoperative CBCT imaging to evaluate the dentin thickness, centering ability, and canal transportation of both groups. Instrumentation time was noted using a stopwatch.</p><p><strong>Results: </strong>There is a statistically significant difference in the instrumentation time; Pedoflex took a shorter time when compared to Pro AF Baby Gold files. Regarding canal transportation, there was no significant difference between the two files, with Pedoflex showing a better value than the other files. Regarding centering ability, there was no significant difference between the two files, with Pro AF Baby Gold having a better value than the other files (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>From the findings of our present study, it was found that both systems were able to effectively shape curved root canals in terms of canal transportation and centering ability.</p><p><strong>How to cite this article: </strong>Busi S, PJ N, Deoghare A, <i>et al.</i> Evaluation and Comparison of Dentin Thickness, Centering Ability, Canal Transportation, and Instrumentation Time of Pro AF Baby Gold and Pedoflex Files in Primary Root Canals Using a Cone Beam Computed Tomographic Analysis: An <i>In Vitro</i> Study. Int J Clin Pediatr Dent 2024;17(8):892-897.</p>","PeriodicalId":36045,"journal":{"name":"International Journal of Clinical Pediatric Dentistry","volume":"17 8","pages":"892-897"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11451867/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation and Comparison of Dentin Thickness, Centering Ability, Canal Transportation, and Instrumentation Time of Pro AF Baby Gold and Pedoflex Files in Primary Root Canals Using a Cone Beam Computed Tomographic Analysis: An <i>In Vitro</i> Study.\",\"authors\":\"Sravanthy Busi, P J Nagarathna, Anushka Deoghare, Keyura Parakh, Rashmi S Lokhande, Swati Malladi\",\"doi\":\"10.5005/jp-journals-10005-2929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Pediatric rotary systems have the advantage of improved canal centricity and conservative canal preparation with better obturation quality. Pro AF Baby Gold and Pedoflex files are two exclusive pediatric rotary file systems that were introduced in recent times.</p><p><strong>Aim and objective: </strong>The aim of the present study is to compare and evaluate the dentine thickness, centering ability, canal transportation, and instrumentation time of Pro AF Baby Gold and Pedoflex files using cone beam computed tomography (CBCT).</p><p><strong>Materials and methods: </strong>A total of 40 extracted human primary molar teeth with a minimum 7 mm root length were included in the study and randomly divided into two groups: group I, Pro AF Baby Gold; group II, Pedoflex files. Teeth were imaged preoperatively with CBCT, then root canal preparation was done in both groups with respective files, followed by postoperative CBCT imaging to evaluate the dentin thickness, centering ability, and canal transportation of both groups. Instrumentation time was noted using a stopwatch.</p><p><strong>Results: </strong>There is a statistically significant difference in the instrumentation time; Pedoflex took a shorter time when compared to Pro AF Baby Gold files. Regarding canal transportation, there was no significant difference between the two files, with Pedoflex showing a better value than the other files. Regarding centering ability, there was no significant difference between the two files, with Pro AF Baby Gold having a better value than the other files (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>From the findings of our present study, it was found that both systems were able to effectively shape curved root canals in terms of canal transportation and centering ability.</p><p><strong>How to cite this article: </strong>Busi S, PJ N, Deoghare A, <i>et al.</i> Evaluation and Comparison of Dentin Thickness, Centering Ability, Canal Transportation, and Instrumentation Time of Pro AF Baby Gold and Pedoflex Files in Primary Root Canals Using a Cone Beam Computed Tomographic Analysis: An <i>In Vitro</i> Study. Int J Clin Pediatr Dent 2024;17(8):892-897.</p>\",\"PeriodicalId\":36045,\"journal\":{\"name\":\"International Journal of Clinical Pediatric Dentistry\",\"volume\":\"17 8\",\"pages\":\"892-897\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11451867/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Clinical Pediatric Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10005-2929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Clinical Pediatric Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10005-2929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
简介小儿旋转锉系统的优点是改善了根管中心性和根管预备的保守性,并具有更好的封闭质量。Pro AF Baby Gold和Pedoflex锉是近年推出的两种独特的儿童旋转锉系统:本研究的目的是使用锥形束计算机断层扫描(CBCT)比较和评估 Pro AF Baby Gold 和 Pedoflex锉的牙本质厚度、居中能力、根管运输和器械操作时间:共有 40 颗牙根长度不小于 7 mm 的人类基磨牙被纳入研究,并随机分为两组:第一组,Pro AF Baby Gold;第二组,Pedoflex 锉刀。术前使用 CBCT 对牙齿进行成像,然后在两组中使用各自的根管锉进行根管预备,再进行术后 CBCT 成像,以评估两组的牙本质厚度、居中能力和根管运输情况。使用秒表记录器械操作时间:结果:两组的器械操作时间在统计学上有显著差异;与 Pro AF Baby Gold 锉相比,Pedoflex 用时更短。在牙道运输方面,两种牙粉没有明显差异,Pedoflex的价值高于其他牙粉。在居中能力方面,两种牙粉没有明显差异,Pro AF Baby Gold牙粉的居中能力优于其他牙粉(P < 0.001):本研究结果表明,从根管运输和居中能力来看,两种系统都能有效地塑造弯曲根管:Busi S, PJ N, Deoghare A, et al. 使用锥形束计算机断层扫描分析评估和比较 Pro AF Baby Gold 和 Pedoflex 锉在基层根管中的牙本质厚度、居中能力、根管运输和器械操作时间:体外研究。Int J Clin Pediatr Dent 2024;17(8):892-897.
Evaluation and Comparison of Dentin Thickness, Centering Ability, Canal Transportation, and Instrumentation Time of Pro AF Baby Gold and Pedoflex Files in Primary Root Canals Using a Cone Beam Computed Tomographic Analysis: An In Vitro Study.
Introduction: Pediatric rotary systems have the advantage of improved canal centricity and conservative canal preparation with better obturation quality. Pro AF Baby Gold and Pedoflex files are two exclusive pediatric rotary file systems that were introduced in recent times.
Aim and objective: The aim of the present study is to compare and evaluate the dentine thickness, centering ability, canal transportation, and instrumentation time of Pro AF Baby Gold and Pedoflex files using cone beam computed tomography (CBCT).
Materials and methods: A total of 40 extracted human primary molar teeth with a minimum 7 mm root length were included in the study and randomly divided into two groups: group I, Pro AF Baby Gold; group II, Pedoflex files. Teeth were imaged preoperatively with CBCT, then root canal preparation was done in both groups with respective files, followed by postoperative CBCT imaging to evaluate the dentin thickness, centering ability, and canal transportation of both groups. Instrumentation time was noted using a stopwatch.
Results: There is a statistically significant difference in the instrumentation time; Pedoflex took a shorter time when compared to Pro AF Baby Gold files. Regarding canal transportation, there was no significant difference between the two files, with Pedoflex showing a better value than the other files. Regarding centering ability, there was no significant difference between the two files, with Pro AF Baby Gold having a better value than the other files (p < 0.001).
Conclusion: From the findings of our present study, it was found that both systems were able to effectively shape curved root canals in terms of canal transportation and centering ability.
How to cite this article: Busi S, PJ N, Deoghare A, et al. Evaluation and Comparison of Dentin Thickness, Centering Ability, Canal Transportation, and Instrumentation Time of Pro AF Baby Gold and Pedoflex Files in Primary Root Canals Using a Cone Beam Computed Tomographic Analysis: An In Vitro Study. Int J Clin Pediatr Dent 2024;17(8):892-897.