超声波检查治疗玻尿酸引起的唇部并发症。

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Imaging Science in Dentistry Pub Date : 2024-09-01 Epub Date: 2024-07-17 DOI:10.5624/isd.20240014
Hyago Portela Figueiredo, Fernanda Coimbra, Tânia de Carvalho Rocha, Micena Roberta Miranda Alves E Silva
{"title":"超声波检查治疗玻尿酸引起的唇部并发症。","authors":"Hyago Portela Figueiredo, Fernanda Coimbra, Tânia de Carvalho Rocha, Micena Roberta Miranda Alves E Silva","doi":"10.5624/isd.20240014","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrasonography is highly accurate for evaluating soft tissues. Given that minimally invasive aesthetic procedures are on the rise, complications have become more prevalent. Thus, ultrasonography holds promise for assisting in the diagnosis and management of complications arising from these interventions. This report highlights the importance of ultrasonography in the treatment of complications caused by hyaluronic acid injection. A patient visited a dental office 24 hours after hyaluronic acid application, presenting pain and bruising in the middle and inferior thirds of the face on the right side. To evaluate blood vessels, the surgeon used Doppler-mode ultrasonography, which enabled the precise application of hyaluronidase to reestablish blood perfusion and preserve adjacent structures. Therefore, to avoid severe outcomes, such as necrosis or even amaurosis, the use of ultrasonography is suggested, improving the precision and safety of these procedures.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"54 3","pages":"296-302"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11450409/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ultrasonography in the management of lip complications caused by hyaluronic acid.\",\"authors\":\"Hyago Portela Figueiredo, Fernanda Coimbra, Tânia de Carvalho Rocha, Micena Roberta Miranda Alves E Silva\",\"doi\":\"10.5624/isd.20240014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrasonography is highly accurate for evaluating soft tissues. Given that minimally invasive aesthetic procedures are on the rise, complications have become more prevalent. Thus, ultrasonography holds promise for assisting in the diagnosis and management of complications arising from these interventions. This report highlights the importance of ultrasonography in the treatment of complications caused by hyaluronic acid injection. A patient visited a dental office 24 hours after hyaluronic acid application, presenting pain and bruising in the middle and inferior thirds of the face on the right side. To evaluate blood vessels, the surgeon used Doppler-mode ultrasonography, which enabled the precise application of hyaluronidase to reestablish blood perfusion and preserve adjacent structures. Therefore, to avoid severe outcomes, such as necrosis or even amaurosis, the use of ultrasonography is suggested, improving the precision and safety of these procedures.</p>\",\"PeriodicalId\":51714,\"journal\":{\"name\":\"Imaging Science in Dentistry\",\"volume\":\"54 3\",\"pages\":\"296-302\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11450409/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging Science in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5624/isd.20240014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20240014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

超声波检查在评估软组织方面具有很高的准确性。鉴于微创美容手术日益增多,并发症也变得越来越普遍。因此,超声波检查有望协助诊断和处理这些干预措施引起的并发症。本报告强调了超声波检查在治疗透明质酸注射引起的并发症方面的重要性。一名患者在注射玻尿酸 24 小时后到牙科诊所就诊,表现为右侧面部中下三分之二处疼痛和瘀伤。为了评估血管情况,外科医生使用了多普勒超声模式,从而能够精确地使用透明质酸酶来重建血液灌注并保护邻近结构。因此,为避免出现坏死甚至无畸形等严重后果,建议使用超声波检查,以提高此类手术的精确性和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasonography in the management of lip complications caused by hyaluronic acid.

Ultrasonography is highly accurate for evaluating soft tissues. Given that minimally invasive aesthetic procedures are on the rise, complications have become more prevalent. Thus, ultrasonography holds promise for assisting in the diagnosis and management of complications arising from these interventions. This report highlights the importance of ultrasonography in the treatment of complications caused by hyaluronic acid injection. A patient visited a dental office 24 hours after hyaluronic acid application, presenting pain and bruising in the middle and inferior thirds of the face on the right side. To evaluate blood vessels, the surgeon used Doppler-mode ultrasonography, which enabled the precise application of hyaluronidase to reestablish blood perfusion and preserve adjacent structures. Therefore, to avoid severe outcomes, such as necrosis or even amaurosis, the use of ultrasonography is suggested, improving the precision and safety of these procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
期刊最新文献
Classification of mandibular molar furcation involvement in periapical radiographs by deep learning. Clinical validity and precision of deep learning-based cone-beam computed tomography automatic landmarking algorithm. Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant. Erratum to: McCune-Albright syndrome with acromegaly: A case report with characteristic radiographic features of fibrous dysplasia. Evaluation of deep learning and convolutional neural network algorithms for mandibular fracture detection using radiographic images: A systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1