人体膝关节在最大自主等长屈曲状态下的生物力学:研究应用力矩、激动-拮抗参与、关节中心和屈曲角度的变化。

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2024-10-09 DOI:10.1002/cnm.3874
Pooya Salehi, Aboulfazl Shirazi-Adl, Farshid Ghezelbash
{"title":"人体膝关节在最大自主等长屈曲状态下的生物力学:研究应用力矩、激动-拮抗参与、关节中心和屈曲角度的变化。","authors":"Pooya Salehi, Aboulfazl Shirazi-Adl, Farshid Ghezelbash","doi":"10.1002/cnm.3874","DOIUrl":null,"url":null,"abstract":"<p><p>Estimation of the knee joint strength by maximum voluntary isometric contraction (MVIC) is a common practice to assess strength, coordination, safety to return to work or engage in sports after an injury, and to evaluate the efficacy of treatment modalities and rehabilitation strategies. In this study, we utilize a previously validated coupled finite element-musculoskeletal model of the lower extremity to explore the sensitivity of output measures (posterior cruciate ligament [PCL]/muscle/contact forces and passive moments) in knee MVIC flexion exercises at seated position. To do so, at three knee flexion angles (KFA), input measures (resistance moment and contribution moments of quadriceps and gastrocnemii) were varied at four levels each using the Taguchi design of experiment. Our findings reveal significant increases in PCL forces with KFA (p < 0.01), net MVIC moment (p < 0.01), and resistance moment of quadriceps (p < 0.01). In contrast, they drop at larger activity in gastrocnemii (p < 0.01). Tibiofemoral (TF) contact forces increase with the net MVIC moment (p < 0.01). The passive knee flexion moment, while highly dependent on the location at which computed, also increases with the net MVIC moment (p < 0.01). Changes in KFA, MVIC moment, and proportions thereof carried by quadriceps and/or gastrocnemii substantially affect biomechanics of the joint. Compared with level walking and stair ascent, slightly larger contact forces/stresses and much greater PCL forces are computed. This study improves our understanding of the knee joint behavior during MVIC in effective evaluation and rehabilitation interventions. Besides, it emphasizes the importance of positioning the joint center in model studies.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanics of the Human Knee Joint in Maximum Voluntary Isometric Flexion: Study of Changes in Applied Moment, Agonist-Antagonist Participations, Joint Center, and Flexion Angle.\",\"authors\":\"Pooya Salehi, Aboulfazl Shirazi-Adl, Farshid Ghezelbash\",\"doi\":\"10.1002/cnm.3874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Estimation of the knee joint strength by maximum voluntary isometric contraction (MVIC) is a common practice to assess strength, coordination, safety to return to work or engage in sports after an injury, and to evaluate the efficacy of treatment modalities and rehabilitation strategies. In this study, we utilize a previously validated coupled finite element-musculoskeletal model of the lower extremity to explore the sensitivity of output measures (posterior cruciate ligament [PCL]/muscle/contact forces and passive moments) in knee MVIC flexion exercises at seated position. To do so, at three knee flexion angles (KFA), input measures (resistance moment and contribution moments of quadriceps and gastrocnemii) were varied at four levels each using the Taguchi design of experiment. Our findings reveal significant increases in PCL forces with KFA (p < 0.01), net MVIC moment (p < 0.01), and resistance moment of quadriceps (p < 0.01). In contrast, they drop at larger activity in gastrocnemii (p < 0.01). Tibiofemoral (TF) contact forces increase with the net MVIC moment (p < 0.01). The passive knee flexion moment, while highly dependent on the location at which computed, also increases with the net MVIC moment (p < 0.01). Changes in KFA, MVIC moment, and proportions thereof carried by quadriceps and/or gastrocnemii substantially affect biomechanics of the joint. Compared with level walking and stair ascent, slightly larger contact forces/stresses and much greater PCL forces are computed. This study improves our understanding of the knee joint behavior during MVIC in effective evaluation and rehabilitation interventions. Besides, it emphasizes the importance of positioning the joint center in model studies.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/cnm.3874\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/cnm.3874","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

通过最大自主等长收缩(MVIC)估算膝关节力量是一种常见的做法,用于评估力量、协调性、受伤后重返工作岗位或参加运动的安全性,以及评估治疗方法和康复策略的效果。在本研究中,我们利用之前验证过的下肢有限元-肌肉骨骼耦合模型,探讨了坐位膝关节 MVIC 屈伸练习中输出测量(后交叉韧带 [PCL] / 肌肉/接触力和被动力矩)的敏感性。为此,采用田口试验设计法,在三个膝关节屈曲角度(KFA)下,对输入指标(股四头肌和腓肠肌的阻力矩和贡献力矩)分别进行了四个水平的改变。我们的研究结果表明,随着 KFA 的增加,PCL 的力量也会明显增加(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biomechanics of the Human Knee Joint in Maximum Voluntary Isometric Flexion: Study of Changes in Applied Moment, Agonist-Antagonist Participations, Joint Center, and Flexion Angle.

Estimation of the knee joint strength by maximum voluntary isometric contraction (MVIC) is a common practice to assess strength, coordination, safety to return to work or engage in sports after an injury, and to evaluate the efficacy of treatment modalities and rehabilitation strategies. In this study, we utilize a previously validated coupled finite element-musculoskeletal model of the lower extremity to explore the sensitivity of output measures (posterior cruciate ligament [PCL]/muscle/contact forces and passive moments) in knee MVIC flexion exercises at seated position. To do so, at three knee flexion angles (KFA), input measures (resistance moment and contribution moments of quadriceps and gastrocnemii) were varied at four levels each using the Taguchi design of experiment. Our findings reveal significant increases in PCL forces with KFA (p < 0.01), net MVIC moment (p < 0.01), and resistance moment of quadriceps (p < 0.01). In contrast, they drop at larger activity in gastrocnemii (p < 0.01). Tibiofemoral (TF) contact forces increase with the net MVIC moment (p < 0.01). The passive knee flexion moment, while highly dependent on the location at which computed, also increases with the net MVIC moment (p < 0.01). Changes in KFA, MVIC moment, and proportions thereof carried by quadriceps and/or gastrocnemii substantially affect biomechanics of the joint. Compared with level walking and stair ascent, slightly larger contact forces/stresses and much greater PCL forces are computed. This study improves our understanding of the knee joint behavior during MVIC in effective evaluation and rehabilitation interventions. Besides, it emphasizes the importance of positioning the joint center in model studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms. Modeling Fibrin Accumulation on Flow-Diverting Devices for Intracranial Aneurysms. A comparison of machine learning methods for recovering noisy and missing 4D flow MRI data. A semi-automatic method for block-structured hexahedral meshing of aortic dissections. Fluid-structure interaction analysis of a healthy aortic valve and its surrounding haemodynamics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1