用于个别前牙扭力调整的新型压接式门弹簧与传统矩形弓丝的生物力学效应:有限元比较研究。

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie Pub Date : 2024-10-08 DOI:10.1007/s00056-024-00554-x
Jia-Rong Liu, Xin-Ran Xu, Xing-Yue Wang, Yan Zhang, Xiao-Ming Wang
{"title":"用于个别前牙扭力调整的新型压接式门弹簧与传统矩形弓丝的生物力学效应:有限元比较研究。","authors":"Jia-Rong Liu, Xin-Ran Xu, Xing-Yue Wang, Yan Zhang, Xiao-Ming Wang","doi":"10.1007/s00056-024-00554-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Precise root torque adjustment of anterior teeth is indispensable for optimizing dental esthetics and occlusal stability in orthodontics. The efficiency of traditional rectangular archwire manipulation within bracket slots seems to be limited. The crimpable gate spring, a novel device, has emerged as a promising alternative. Yet, there is a paucity of guidelines for its optimal clinical application. This study used finite element analysis (FEA) to investigate the biomechanical impact of the gate spring on torque adjustment of individual anterior teeth and to elucidate the most effective application strategy.</p><p><strong>Methods: </strong>A FEA model was constructed by a maxillary central incisor affixed with an edgewise bracket featuring a 0.022 × 0.028 inch (in) slot. A range of stainless steel rectangular archwires, in conjunction with a gate spring, were modeled and simulated within the bracket slots. A control group utilized a conventional rectangular wire devoid of a gate spring. Palatal root moments were standardized to 9, 18, and 36 Nmm for both experimental and control groups.</p><p><strong>Results: </strong>The gate spring significantly amplified palatal root movement, notably with the 0.019 × 0.025 in archwire. However, this was accompanied by an increase in stress on the tooth and periodontal ligament, particularly in the cervical regions. The synergistic use of a 0.019 × 0.025 in rectangular archwire with a gate spring in a 0.022 × 0.028 in bracket slot was identified as most efficacious for torque control of individual anterior teeth.</p><p><strong>Conclusions: </strong>The gate spring is a viable auxiliary device for enhancing torque adjustment on individual teeth. However, caution is advised as excessive initial stress may concentrate in the cervical and apical regions of the periodontal ligament and tooth.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical effects of a new crimpable gate spring combined with conventional rectangular archwires for torque adjustment of individual anterior teeth : A comparative finite element study.\",\"authors\":\"Jia-Rong Liu, Xin-Ran Xu, Xing-Yue Wang, Yan Zhang, Xiao-Ming Wang\",\"doi\":\"10.1007/s00056-024-00554-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Precise root torque adjustment of anterior teeth is indispensable for optimizing dental esthetics and occlusal stability in orthodontics. The efficiency of traditional rectangular archwire manipulation within bracket slots seems to be limited. The crimpable gate spring, a novel device, has emerged as a promising alternative. Yet, there is a paucity of guidelines for its optimal clinical application. This study used finite element analysis (FEA) to investigate the biomechanical impact of the gate spring on torque adjustment of individual anterior teeth and to elucidate the most effective application strategy.</p><p><strong>Methods: </strong>A FEA model was constructed by a maxillary central incisor affixed with an edgewise bracket featuring a 0.022 × 0.028 inch (in) slot. A range of stainless steel rectangular archwires, in conjunction with a gate spring, were modeled and simulated within the bracket slots. A control group utilized a conventional rectangular wire devoid of a gate spring. Palatal root moments were standardized to 9, 18, and 36 Nmm for both experimental and control groups.</p><p><strong>Results: </strong>The gate spring significantly amplified palatal root movement, notably with the 0.019 × 0.025 in archwire. However, this was accompanied by an increase in stress on the tooth and periodontal ligament, particularly in the cervical regions. The synergistic use of a 0.019 × 0.025 in rectangular archwire with a gate spring in a 0.022 × 0.028 in bracket slot was identified as most efficacious for torque control of individual anterior teeth.</p><p><strong>Conclusions: </strong>The gate spring is a viable auxiliary device for enhancing torque adjustment on individual teeth. However, caution is advised as excessive initial stress may concentrate in the cervical and apical regions of the periodontal ligament and tooth.</p>\",\"PeriodicalId\":54776,\"journal\":{\"name\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00056-024-00554-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-024-00554-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:在正畸过程中,前牙根部扭矩的精确调整对于优化牙齿美学和咬合稳定性是不可或缺的。传统的矩形弓丝在托槽内的操作效率似乎有限。可卷曲闸板弹簧作为一种新型装置,已成为一种很有前途的替代方案。然而,关于其最佳临床应用的指南却很少。本研究使用有限元分析(FEA)来研究门弹簧对个别前牙扭力调节的生物力学影响,并阐明最有效的应用策略:有限元分析模型由一颗上颌中切牙构建而成,该上颌中切牙上有一个 0.022 × 0.028 英寸(英寸)的边缘托槽。在托槽内对一系列不锈钢矩形弓丝和门弹簧进行了建模和模拟。对照组使用的是没有门弹簧的传统矩形弓丝。实验组和对照组的腭根力矩标准化为 9、18 和 36 Nmm:结果:门弹簧明显增加了腭根的移动,尤其是在弓丝为 0.019 × 0.025 的情况下。然而,随之而来的是牙齿和牙周韧带的应力增加,尤其是在牙颈部。在 0.022 × 0.028 英寸的托槽中使用 0.019 × 0.025 英寸的矩形弓丝和门式弹簧的协同作用被认为对个别前牙的扭矩控制最为有效:结论:门弹簧是一种可行的辅助装置,可用于加强对个别牙齿的扭矩调节。但需要注意的是,过大的初始应力可能会集中在牙周韧带和牙齿的颈部和根尖部位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biomechanical effects of a new crimpable gate spring combined with conventional rectangular archwires for torque adjustment of individual anterior teeth : A comparative finite element study.

Objective: Precise root torque adjustment of anterior teeth is indispensable for optimizing dental esthetics and occlusal stability in orthodontics. The efficiency of traditional rectangular archwire manipulation within bracket slots seems to be limited. The crimpable gate spring, a novel device, has emerged as a promising alternative. Yet, there is a paucity of guidelines for its optimal clinical application. This study used finite element analysis (FEA) to investigate the biomechanical impact of the gate spring on torque adjustment of individual anterior teeth and to elucidate the most effective application strategy.

Methods: A FEA model was constructed by a maxillary central incisor affixed with an edgewise bracket featuring a 0.022 × 0.028 inch (in) slot. A range of stainless steel rectangular archwires, in conjunction with a gate spring, were modeled and simulated within the bracket slots. A control group utilized a conventional rectangular wire devoid of a gate spring. Palatal root moments were standardized to 9, 18, and 36 Nmm for both experimental and control groups.

Results: The gate spring significantly amplified palatal root movement, notably with the 0.019 × 0.025 in archwire. However, this was accompanied by an increase in stress on the tooth and periodontal ligament, particularly in the cervical regions. The synergistic use of a 0.019 × 0.025 in rectangular archwire with a gate spring in a 0.022 × 0.028 in bracket slot was identified as most efficacious for torque control of individual anterior teeth.

Conclusions: The gate spring is a viable auxiliary device for enhancing torque adjustment on individual teeth. However, caution is advised as excessive initial stress may concentrate in the cervical and apical regions of the periodontal ligament and tooth.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
期刊最新文献
The effects of professional expertise on perceptions of treatment need in patients with class II division 1 malocclusion: a comparison between orthodontists, general dentists, and lay people in Germany. Mitteilungen der DGKFO. Effect of orthodontic extraction of mandibular premolars on third molar angulation after treatment with fixed appliances : A cross-sectional study. Long-term effects of orthodontic interceptive expansion treatment : A retrospective study. Scanning electron microscopy evaluation of enamel surfaces using different air-polishing powders in the orthodontic setting: an in vitro study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1