利用新开发的气相沉积系统,ToF-SIMS 研究环境对质谱成像基质涂层中分析物迁移的影响。

IF 3.1 2区 化学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of the American Society for Mass Spectrometry Pub Date : 2024-10-11 DOI:10.1021/jasms.4c00340
Thorsten Adolphs, Michael Bäumer, Florian Bosse, Bart Jan Ravoo, Richard E Peterson, Heinrich F Arlinghaus, Bonnie J Tyler
{"title":"利用新开发的气相沉积系统,ToF-SIMS 研究环境对质谱成像基质涂层中分析物迁移的影响。","authors":"Thorsten Adolphs, Michael Bäumer, Florian Bosse, Bart Jan Ravoo, Richard E Peterson, Heinrich F Arlinghaus, Bonnie J Tyler","doi":"10.1021/jasms.4c00340","DOIUrl":null,"url":null,"abstract":"<p><p>High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix α-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System.\",\"authors\":\"Thorsten Adolphs, Michael Bäumer, Florian Bosse, Bart Jan Ravoo, Richard E Peterson, Heinrich F Arlinghaus, Bonnie J Tyler\",\"doi\":\"10.1021/jasms.4c00340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix α-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.</p>\",\"PeriodicalId\":672,\"journal\":{\"name\":\"Journal of the American Society for Mass Spectrometry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Society for Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/jasms.4c00340\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00340","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

高分辨率质谱图像在组织和单细胞研究等生物应用领域的重要性与日俱增。基质增强二次离子质谱(ME-SIMS)和基质辅助激光解吸/电离(MALDI)是两种很有前途的技术。对于这两种技术,在分析前必须在相关样品上涂覆基质,分析物必须迁移到基质中。人们对这种迁移所涉及的机制以及影响迁移的因素知之甚少,这导致了重现性方面的困难。在这项工作中,我们开发并在公司内部建立了一个带有喷流室和样品冷却装置的升华基质涂层器,用于控制物理气相沉积。在该系统中,镀膜机和质谱仪之间的样品转移无需破坏真空,这为研究环境对分析物迁移的影响提供了便利。利用 3D-SIMS 成像技术研究了暴露在环境空气中对涂有基质 α-氰基-4-羟基肉桂酸(CHCA)的两种分析物(一种脂质和一种肽)迁移的影响。虽然分析物在基质中的分布在真空中储存 21 小时后变化很小,但暴露在环境空气中后观察到分析物有明显的重新分布。脂质的影响程度大于肽。需要进一步研究湿度在重新分布过程中的作用以及分析物重新分布对 MALDI 测量的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System.

High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix α-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.50
自引率
9.40%
发文量
257
审稿时长
1 months
期刊介绍: The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role. Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives
期刊最新文献
Infrared Laser Ablation and Capture of Formalin-Fixed Paraffin-Embedded Tissue. Quantitative Analysis of Drugs in a Mimetic Tissue Model Using Nano-DESI on a Triple Quadrupole Mass Spectrometer. Development of a Novel Label-Free Subunit HILIC-MS Method for Domain-Specific Free Thiol Identification and Quantitation in Therapeutic Monoclonal Antibodies. Single Cell MALDI-MSI Analysis of Lipids and Proteins within a Replicative Senescence Fibroblast Model. Processing Next-Generation Mass Spectrometry Imaging Data: Principal Component Analysis at Scale.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1