基于荧光素的等电点低分子质量标记,利用高灵敏度毛细管等电聚焦和激光诱导荧光检测技术追踪 pH 梯度

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL Analytica Chimica Acta Pub Date : 2024-10-11 DOI:10.1016/j.aca.2024.343331
Pavlína Dadajová, Richard Čmelík, Karel Šlais, Filip Duša
{"title":"基于荧光素的等电点低分子质量标记,利用高灵敏度毛细管等电聚焦和激光诱导荧光检测技术追踪 pH 梯度","authors":"Pavlína Dadajová, Richard Čmelík, Karel Šlais, Filip Duša","doi":"10.1016/j.aca.2024.343331","DOIUrl":null,"url":null,"abstract":"<h3>Background</h3>Successful implementation of capillary isoelectric focusing (cIEF) in general requires the use of reference points - markers of isoelectric point. The low-molecular-mass fluorescent compounds based on the fluorescein structure, capable of marking distinct isoelectric points (p<em>I</em>s) with good focusing ability, stability, high extinction coefficient, and fluorescence are an alternative to the peptide and protein p<em>I</em> markers.<h3>Results</h3>Four synthetic pathways were used to produce the ampholytic compounds and the structures along with their basic physical and chemical properties are given. Previously published low-molecular-mass p<em>I</em> markers were used to calibrate the candidate fluorescent compounds using capillary IEF (cIEF) with laser-induced fluorescence (LIF) detection. Linear and point-to-point p<em>I</em> calibration approach were compared for the p<em>I</em> evaluation. The results show 21 fluorescent p<em>I</em> markers (FPIMs). This group of markers covers pH range from 3.10 to 10.21. The usability of the developed FPIMs was further demonstrated by analysis of fluorescein isothiocyanate (FITC) labeled immunoglobin (IgG) standard.<h3>Significance and Novelty</h3>p<em>I</em> markers are crucial for tracking the pH gradient and p<em>I</em> determination of biological ampholytic compounds. This paper presents and characterizes a novel p<em>I</em> marker set capable of tracing isoelectric points and supporting highly sensitive LIF detection-based applications. A basis of a newly developed cIEF-based fractionation method is described as well.","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fluorescein-based low-molecular-mass markers of isoelectric point for tracing pH gradient using high sensitivity capillary isoelectric focusing with laser-induced fluorescence detection\",\"authors\":\"Pavlína Dadajová, Richard Čmelík, Karel Šlais, Filip Duša\",\"doi\":\"10.1016/j.aca.2024.343331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Background</h3>Successful implementation of capillary isoelectric focusing (cIEF) in general requires the use of reference points - markers of isoelectric point. The low-molecular-mass fluorescent compounds based on the fluorescein structure, capable of marking distinct isoelectric points (p<em>I</em>s) with good focusing ability, stability, high extinction coefficient, and fluorescence are an alternative to the peptide and protein p<em>I</em> markers.<h3>Results</h3>Four synthetic pathways were used to produce the ampholytic compounds and the structures along with their basic physical and chemical properties are given. Previously published low-molecular-mass p<em>I</em> markers were used to calibrate the candidate fluorescent compounds using capillary IEF (cIEF) with laser-induced fluorescence (LIF) detection. Linear and point-to-point p<em>I</em> calibration approach were compared for the p<em>I</em> evaluation. The results show 21 fluorescent p<em>I</em> markers (FPIMs). This group of markers covers pH range from 3.10 to 10.21. The usability of the developed FPIMs was further demonstrated by analysis of fluorescein isothiocyanate (FITC) labeled immunoglobin (IgG) standard.<h3>Significance and Novelty</h3>p<em>I</em> markers are crucial for tracking the pH gradient and p<em>I</em> determination of biological ampholytic compounds. This paper presents and characterizes a novel p<em>I</em> marker set capable of tracing isoelectric points and supporting highly sensitive LIF detection-based applications. A basis of a newly developed cIEF-based fractionation method is described as well.\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.aca.2024.343331\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.aca.2024.343331","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景毛细管等电聚焦(cIEF)的成功实施一般需要使用参考点--等电点标记物。基于荧光素结构的低分子质量荧光化合物能够标记不同的等电点(pIs),具有良好的聚焦能力、稳定性、高消光系数和荧光性,是肽和蛋白质 pI 标记的替代品。使用毛细管 IEF(cIEF)和激光诱导荧光(LIF)检测法校准了以前发表的低分子质量 pI 标记的候选荧光化合物。对线性和点对点 pI 校准方法进行了比较。结果显示了 21 种荧光 pI 标记(FPIMs)。这组标记的 pH 值范围从 3.10 到 10.21。通过分析异硫氰酸荧光素(FITC)标记的免疫球蛋白(IgG)标准,进一步证明了所开发的 FPIMs 的可用性。本文介绍了一种新型 pI 标记集,它能够追踪等电点并支持基于 LIF 检测的高灵敏度应用。本文还介绍了新开发的基于 cIEF 的分馏方法的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fluorescein-based low-molecular-mass markers of isoelectric point for tracing pH gradient using high sensitivity capillary isoelectric focusing with laser-induced fluorescence detection

Background

Successful implementation of capillary isoelectric focusing (cIEF) in general requires the use of reference points - markers of isoelectric point. The low-molecular-mass fluorescent compounds based on the fluorescein structure, capable of marking distinct isoelectric points (pIs) with good focusing ability, stability, high extinction coefficient, and fluorescence are an alternative to the peptide and protein pI markers.

Results

Four synthetic pathways were used to produce the ampholytic compounds and the structures along with their basic physical and chemical properties are given. Previously published low-molecular-mass pI markers were used to calibrate the candidate fluorescent compounds using capillary IEF (cIEF) with laser-induced fluorescence (LIF) detection. Linear and point-to-point pI calibration approach were compared for the pI evaluation. The results show 21 fluorescent pI markers (FPIMs). This group of markers covers pH range from 3.10 to 10.21. The usability of the developed FPIMs was further demonstrated by analysis of fluorescein isothiocyanate (FITC) labeled immunoglobin (IgG) standard.

Significance and Novelty

pI markers are crucial for tracking the pH gradient and pI determination of biological ampholytic compounds. This paper presents and characterizes a novel pI marker set capable of tracing isoelectric points and supporting highly sensitive LIF detection-based applications. A basis of a newly developed cIEF-based fractionation method is described as well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
期刊最新文献
Mass-Tagged Self-Assembled Nanoprobe Reveals the Transport of PD-L1 from Cancer Cells to Tumor-Educated Platelets Fluorescein-based low-molecular-mass markers of isoelectric point for tracing pH gradient using high sensitivity capillary isoelectric focusing with laser-induced fluorescence detection Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review. Hierarchically porous covalent organic framework doped monolithic column for on-line chip-based array microextraction of nonsteroidal anti-inflammatory drugs in microlitre volume of blood Frontiers in Laccase Nanozymes-Enabled Colorimetric Sensing: A review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1