Md. Imamul Islam , Mohd Shawal Bin Jadin , Ahmed Al Mansur , Talal Alharbi
{"title":"热带气候下野外老化光伏组件的电气性能和退化分析:对比实验研究","authors":"Md. Imamul Islam , Mohd Shawal Bin Jadin , Ahmed Al Mansur , Talal Alharbi","doi":"10.1016/j.ecmx.2024.100719","DOIUrl":null,"url":null,"abstract":"<div><div>Performance degradation is a prevalent phenomenon in solar photovoltaic systems globally, with varying aging profiles and effects depending on environmental and climatic conditions. This paper presents an extensive investigation of the electrical performance, aging mechanisms, and degradation analysis of field-aged PV modules under the tropical climate of Malaysia. Utilizing a combination of visual inspection, I-V curve measurement, and thermal imaging techniques, this research provides a comprehensive assessment of the electrical and thermal properties of field-aged PV modules from two locations in Malaysia over extended periods (8 years at UMPSA and 10 years at Pasir Mas). The multi-faceted approach of the study allows for a deeper understanding of the degradation process, offering insights into the causes and effects of higher current and lower voltage in aged modules. The study found the average annual degradation rates at UMPSA were 0.3% for open circuit voltage (<span><math><mrow><msub><mrow><mi>V</mi></mrow><mrow><mi>oc</mi></mrow></msub></mrow></math></span>), 0.23% for short circuit current (<span><math><mrow><msub><mrow><mi>I</mi></mrow><mrow><mi>sc</mi></mrow></msub></mrow></math></span>), 0.81% for maximum power (<span><math><mrow><msub><mrow><mi>P</mi></mrow><mrow><mi>max</mi></mrow></msub></mrow></math></span>), and 0.35% for fill factor (FF) and at Pasir Mas, the average annual degradation rates were 1.124% for Voc, −0.166% for Isc, 1.276% for Pmax, and 0.43% for FF. The study also found that monocrystalline silicon (m-Si) panels experienced an average power degradation of 6.48%, while polycrystalline silicon (p-Si) panels showed a higher degradation of 12.76%. However, Thermal imaging revealed significant temperature variations across the modules, with hotspots reaching up to 11.2 °C above cooler areas in UMPSA panels and an even more pronounced 26.1 °C difference in Pasir Mas modules. These temperature disparities highlight the uneven heat distribution and potential performance issues in the panels. This research contributes to the understanding of PV module degradation in tropical climates and aligns with sustainable development, climate change mitigation efforts, and SDG 7 by promoting sustainable energy solutions.</div></div>","PeriodicalId":37131,"journal":{"name":"Energy Conversion and Management-X","volume":"24 ","pages":"Article 100719"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrical Performance and Degradation Analysis of Field-Aged PV Modules in Tropical Climates: A Comparative Experimental Study\",\"authors\":\"Md. Imamul Islam , Mohd Shawal Bin Jadin , Ahmed Al Mansur , Talal Alharbi\",\"doi\":\"10.1016/j.ecmx.2024.100719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Performance degradation is a prevalent phenomenon in solar photovoltaic systems globally, with varying aging profiles and effects depending on environmental and climatic conditions. This paper presents an extensive investigation of the electrical performance, aging mechanisms, and degradation analysis of field-aged PV modules under the tropical climate of Malaysia. Utilizing a combination of visual inspection, I-V curve measurement, and thermal imaging techniques, this research provides a comprehensive assessment of the electrical and thermal properties of field-aged PV modules from two locations in Malaysia over extended periods (8 years at UMPSA and 10 years at Pasir Mas). The multi-faceted approach of the study allows for a deeper understanding of the degradation process, offering insights into the causes and effects of higher current and lower voltage in aged modules. The study found the average annual degradation rates at UMPSA were 0.3% for open circuit voltage (<span><math><mrow><msub><mrow><mi>V</mi></mrow><mrow><mi>oc</mi></mrow></msub></mrow></math></span>), 0.23% for short circuit current (<span><math><mrow><msub><mrow><mi>I</mi></mrow><mrow><mi>sc</mi></mrow></msub></mrow></math></span>), 0.81% for maximum power (<span><math><mrow><msub><mrow><mi>P</mi></mrow><mrow><mi>max</mi></mrow></msub></mrow></math></span>), and 0.35% for fill factor (FF) and at Pasir Mas, the average annual degradation rates were 1.124% for Voc, −0.166% for Isc, 1.276% for Pmax, and 0.43% for FF. The study also found that monocrystalline silicon (m-Si) panels experienced an average power degradation of 6.48%, while polycrystalline silicon (p-Si) panels showed a higher degradation of 12.76%. However, Thermal imaging revealed significant temperature variations across the modules, with hotspots reaching up to 11.2 °C above cooler areas in UMPSA panels and an even more pronounced 26.1 °C difference in Pasir Mas modules. These temperature disparities highlight the uneven heat distribution and potential performance issues in the panels. This research contributes to the understanding of PV module degradation in tropical climates and aligns with sustainable development, climate change mitigation efforts, and SDG 7 by promoting sustainable energy solutions.</div></div>\",\"PeriodicalId\":37131,\"journal\":{\"name\":\"Energy Conversion and Management-X\",\"volume\":\"24 \",\"pages\":\"Article 100719\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management-X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590174524001971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management-X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590174524001971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Electrical Performance and Degradation Analysis of Field-Aged PV Modules in Tropical Climates: A Comparative Experimental Study
Performance degradation is a prevalent phenomenon in solar photovoltaic systems globally, with varying aging profiles and effects depending on environmental and climatic conditions. This paper presents an extensive investigation of the electrical performance, aging mechanisms, and degradation analysis of field-aged PV modules under the tropical climate of Malaysia. Utilizing a combination of visual inspection, I-V curve measurement, and thermal imaging techniques, this research provides a comprehensive assessment of the electrical and thermal properties of field-aged PV modules from two locations in Malaysia over extended periods (8 years at UMPSA and 10 years at Pasir Mas). The multi-faceted approach of the study allows for a deeper understanding of the degradation process, offering insights into the causes and effects of higher current and lower voltage in aged modules. The study found the average annual degradation rates at UMPSA were 0.3% for open circuit voltage (), 0.23% for short circuit current (), 0.81% for maximum power (), and 0.35% for fill factor (FF) and at Pasir Mas, the average annual degradation rates were 1.124% for Voc, −0.166% for Isc, 1.276% for Pmax, and 0.43% for FF. The study also found that monocrystalline silicon (m-Si) panels experienced an average power degradation of 6.48%, while polycrystalline silicon (p-Si) panels showed a higher degradation of 12.76%. However, Thermal imaging revealed significant temperature variations across the modules, with hotspots reaching up to 11.2 °C above cooler areas in UMPSA panels and an even more pronounced 26.1 °C difference in Pasir Mas modules. These temperature disparities highlight the uneven heat distribution and potential performance issues in the panels. This research contributes to the understanding of PV module degradation in tropical climates and aligns with sustainable development, climate change mitigation efforts, and SDG 7 by promoting sustainable energy solutions.
期刊介绍:
Energy Conversion and Management: X is the open access extension of the reputable journal Energy Conversion and Management, serving as a platform for interdisciplinary research on a wide array of critical energy subjects. The journal is dedicated to publishing original contributions and in-depth technical review articles that present groundbreaking research on topics spanning energy generation, utilization, conversion, storage, transmission, conservation, management, and sustainability.
The scope of Energy Conversion and Management: X encompasses various forms of energy, including mechanical, thermal, nuclear, chemical, electromagnetic, magnetic, and electric energy. It addresses all known energy resources, highlighting both conventional sources like fossil fuels and nuclear power, as well as renewable resources such as solar, biomass, hydro, wind, geothermal, and ocean energy.