高寒地区槽式太阳能空腔接收器隔热板效应的理论和实验研究

IF 4.9 2区 工程技术 Q1 ENGINEERING, MECHANICAL International Journal of Thermal Sciences Pub Date : 2024-10-03 DOI:10.1016/j.ijthermalsci.2024.109445
Zhimin Wang , Shangyu Yue , Wenwu Chan , Gangxing Bian
{"title":"高寒地区槽式太阳能空腔接收器隔热板效应的理论和实验研究","authors":"Zhimin Wang ,&nbsp;Shangyu Yue ,&nbsp;Wenwu Chan ,&nbsp;Gangxing Bian","doi":"10.1016/j.ijthermalsci.2024.109445","DOIUrl":null,"url":null,"abstract":"<div><div>The large heat loss of the cavity receiver limits its application in parabolic trough collectors, matching the environmental factors in alpine areas, in this paper, adding a glass cover plate as a heat shield at the aperture of the trough inverted trapezoidal cavity receiver is investigated. To quantify the optimization of the system performance by adding, an analytical study is carried out for the cavity receiver using theoretical calculations of heat transfer and indoor experimental tests, while “thermal uniformity” is introduced as an indicator of the temperature distribution inside the cavity, and further verifies experimentally by the outdoor real-area environment. The findings indicate that adding a heat shield is significantly effective in reducing heat loss in windy areas. At the flow rate of 250 L/h and inlet temperature of 323 K, the maximum experimental heat loss value is significantly reduced by 70.01 % in the range of 1–5 m/s wind speeds compared to the one without a heat shield. When the wind direction is from −60° to 60°, the heat loss inside the cavity is small after adding, forming a stable stratified flow, and the thermal uniformity decreases by only 0.02, indicating that the stability of the temperature field inside the cavity is high. Furthermore, outdoor validation experiments demonstrate a slower change in heat loss rate with adding the heat shield compared to without, the growth rate of the former is close to 1/3 that of the latter, with a maximum suppressed heat loss rate of 23.49 %. This study provides the theoretical basis and data guidance for optimizing cavity receiver performance in alpine areas.</div></div>","PeriodicalId":341,"journal":{"name":"International Journal of Thermal Sciences","volume":"208 ","pages":"Article 109445"},"PeriodicalIF":4.9000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Theoretical and experimental study on the effect of the heat shield on the trough solar cavity receiver in alpine areas\",\"authors\":\"Zhimin Wang ,&nbsp;Shangyu Yue ,&nbsp;Wenwu Chan ,&nbsp;Gangxing Bian\",\"doi\":\"10.1016/j.ijthermalsci.2024.109445\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The large heat loss of the cavity receiver limits its application in parabolic trough collectors, matching the environmental factors in alpine areas, in this paper, adding a glass cover plate as a heat shield at the aperture of the trough inverted trapezoidal cavity receiver is investigated. To quantify the optimization of the system performance by adding, an analytical study is carried out for the cavity receiver using theoretical calculations of heat transfer and indoor experimental tests, while “thermal uniformity” is introduced as an indicator of the temperature distribution inside the cavity, and further verifies experimentally by the outdoor real-area environment. The findings indicate that adding a heat shield is significantly effective in reducing heat loss in windy areas. At the flow rate of 250 L/h and inlet temperature of 323 K, the maximum experimental heat loss value is significantly reduced by 70.01 % in the range of 1–5 m/s wind speeds compared to the one without a heat shield. When the wind direction is from −60° to 60°, the heat loss inside the cavity is small after adding, forming a stable stratified flow, and the thermal uniformity decreases by only 0.02, indicating that the stability of the temperature field inside the cavity is high. Furthermore, outdoor validation experiments demonstrate a slower change in heat loss rate with adding the heat shield compared to without, the growth rate of the former is close to 1/3 that of the latter, with a maximum suppressed heat loss rate of 23.49 %. This study provides the theoretical basis and data guidance for optimizing cavity receiver performance in alpine areas.</div></div>\",\"PeriodicalId\":341,\"journal\":{\"name\":\"International Journal of Thermal Sciences\",\"volume\":\"208 \",\"pages\":\"Article 109445\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Thermal Sciences\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1290072924005672\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Thermal Sciences","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1290072924005672","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

空腔接收器的热损耗较大,限制了其在抛物面槽式集热器中的应用,为了与高寒地区的环境因素相匹配,本文研究了在槽式倒梯形空腔接收器的开孔处添加玻璃盖板作为隔热层的问题。为了量化加装后系统性能的优化,利用传热理论计算和室内实验测试对空腔接收器进行了分析研究,同时引入了 "热均匀性 "作为空腔内部温度分布的指标,并通过室外实际环境进行了进一步的实验验证。研究结果表明,在多风地区,加装隔热罩能明显有效地减少热量损失。流量为 250 L/h、入口温度为 323 K 时,在 1-5 m/s 的风速范围内,实验的最大热损耗值比不加隔热箱的热损耗值明显降低了 70.01%。当风向为 -60° 至 60° 时,加入隔热罩后,空腔内的热损失很小,形成了稳定的分层流,热均匀度仅降低了 0.02,表明空腔内温度场的稳定性很高。此外,室外验证实验表明,与不加隔热罩相比,加隔热罩后热损失率变化较慢,前者的增长率接近后者的 1/3,最大抑制热损失率为 23.49%。这项研究为优化高寒地区空腔接收器的性能提供了理论依据和数据指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Theoretical and experimental study on the effect of the heat shield on the trough solar cavity receiver in alpine areas
The large heat loss of the cavity receiver limits its application in parabolic trough collectors, matching the environmental factors in alpine areas, in this paper, adding a glass cover plate as a heat shield at the aperture of the trough inverted trapezoidal cavity receiver is investigated. To quantify the optimization of the system performance by adding, an analytical study is carried out for the cavity receiver using theoretical calculations of heat transfer and indoor experimental tests, while “thermal uniformity” is introduced as an indicator of the temperature distribution inside the cavity, and further verifies experimentally by the outdoor real-area environment. The findings indicate that adding a heat shield is significantly effective in reducing heat loss in windy areas. At the flow rate of 250 L/h and inlet temperature of 323 K, the maximum experimental heat loss value is significantly reduced by 70.01 % in the range of 1–5 m/s wind speeds compared to the one without a heat shield. When the wind direction is from −60° to 60°, the heat loss inside the cavity is small after adding, forming a stable stratified flow, and the thermal uniformity decreases by only 0.02, indicating that the stability of the temperature field inside the cavity is high. Furthermore, outdoor validation experiments demonstrate a slower change in heat loss rate with adding the heat shield compared to without, the growth rate of the former is close to 1/3 that of the latter, with a maximum suppressed heat loss rate of 23.49 %. This study provides the theoretical basis and data guidance for optimizing cavity receiver performance in alpine areas.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Thermal Sciences
International Journal of Thermal Sciences 工程技术-工程:机械
CiteScore
8.10
自引率
11.10%
发文量
531
审稿时长
55 days
期刊介绍: The International Journal of Thermal Sciences is a journal devoted to the publication of fundamental studies on the physics of transfer processes in general, with an emphasis on thermal aspects and also applied research on various processes, energy systems and the environment. Articles are published in English and French, and are subject to peer review. The fundamental subjects considered within the scope of the journal are: * Heat and relevant mass transfer at all scales (nano, micro and macro) and in all types of material (heterogeneous, composites, biological,...) and fluid flow * Forced, natural or mixed convection in reactive or non-reactive media * Single or multi–phase fluid flow with or without phase change * Near–and far–field radiative heat transfer * Combined modes of heat transfer in complex systems (for example, plasmas, biological, geological,...) * Multiscale modelling The applied research topics include: * Heat exchangers, heat pipes, cooling processes * Transport phenomena taking place in industrial processes (chemical, food and agricultural, metallurgical, space and aeronautical, automobile industries) * Nano–and micro–technology for energy, space, biosystems and devices * Heat transport analysis in advanced systems * Impact of energy–related processes on environment, and emerging energy systems The study of thermophysical properties of materials and fluids, thermal measurement techniques, inverse methods, and the developments of experimental methods are within the scope of the International Journal of Thermal Sciences which also covers the modelling, and numerical methods applied to thermal transfer.
期刊最新文献
Intelligent decision-making approach for rapid optimization of double-wall cooling structures under varying cooling demands Numerical simulation of battery thermal management based on ring microchannel cold plate Prediction of flow boiling characteristics in manifold microchannel radiator based on high heat flux cooling A quadrupole-based approach for integrated building simulation and energy-efficient load control Optimizing cooling performance of infrared transparent condensation-free radiant cooling by using bubble wrap
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1