使用锥形束计算机断层扫描评估不同旋转锉系统对严重弯曲和突然弯曲根管的整形能力

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Saudi Dental Journal Pub Date : 2024-10-01 DOI:10.1016/j.sdentj.2024.07.016
Chanapa Damkoengsunthon , Adjabhak Wongviriya , Weeraya Tantanapornkul , Kessiri Wisithphrom , Kittipong Ketpan , Thosapol Piyapattamin , Peraya Puapichartdumrong
{"title":"使用锥形束计算机断层扫描评估不同旋转锉系统对严重弯曲和突然弯曲根管的整形能力","authors":"Chanapa Damkoengsunthon ,&nbsp;Adjabhak Wongviriya ,&nbsp;Weeraya Tantanapornkul ,&nbsp;Kessiri Wisithphrom ,&nbsp;Kittipong Ketpan ,&nbsp;Thosapol Piyapattamin ,&nbsp;Peraya Puapichartdumrong","doi":"10.1016/j.sdentj.2024.07.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>When selecting an instrument for canal preparation, it is important to consider several parameters that influence the shaping efficiency, including instrument design, metallurgy, and operating motion. This study aimed to evaluate the shaping ability of the ProTaper Next (PTN), WaveOne Gold (WOG), and XP-endo Rise Shaper (XPRS) rotary systems in severely and abruptly curved root canals using cone beam computed tomography (CBCT) and ImageJ software.</div></div><div><h3>Materials and Methods</h3><div>Forty-eight mesial root canals of the mandibular first molars were assigned equally to three groups: PTN, WOG, and XPRS. Using ImageJ software, CBCT images were acquired pre- and post-instrumentation to assess dentin removal, remaining dentin thickness (RDT), canal transportation, and centering ratio at the coronal, middle, and apical levels. Statistical analyses were conducted on all numerical data.</div></div><div><h3>Results</h3><div>All rotary systems removed significantly more distocoronal dentin in the danger zone (DZ), than the mesiocoronal area. PTN removed significantly more dentin and caused less RDT than XPRS (p &lt; 0.05). However, there were no significant differences between PTN-WOG and WOG-XPRS. In the DZ, the highest percentage of specimens with an RDT &lt; 0.5 mm was observed when using PTN (50%), followed by WOG (31.3%), and XPRS (6.3%). Compared with PTN and WOG, XPRS demonstrated less coronal transportation. Among all rotary systems, there was no significant difference in apical transportation or centering ratio.</div></div><div><h3>Conclusions</h3><div>Based on our observations, all rotary instruments exhibited a tendency to remove dentin in the DZ, but to different degrees. XPRS demonstrated better results in terms of coronal transportation and dentin thickness in the DZ. Comparable centering abilities and minimal apical transportation were demonstrated using all rotary instruments.</div></div>","PeriodicalId":47246,"journal":{"name":"Saudi Dental Journal","volume":"36 10","pages":"Pages 1333-1338"},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the shaping ability of different rotary file systems in severely and abruptly curved root canals using cone beam computed tomography\",\"authors\":\"Chanapa Damkoengsunthon ,&nbsp;Adjabhak Wongviriya ,&nbsp;Weeraya Tantanapornkul ,&nbsp;Kessiri Wisithphrom ,&nbsp;Kittipong Ketpan ,&nbsp;Thosapol Piyapattamin ,&nbsp;Peraya Puapichartdumrong\",\"doi\":\"10.1016/j.sdentj.2024.07.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>When selecting an instrument for canal preparation, it is important to consider several parameters that influence the shaping efficiency, including instrument design, metallurgy, and operating motion. This study aimed to evaluate the shaping ability of the ProTaper Next (PTN), WaveOne Gold (WOG), and XP-endo Rise Shaper (XPRS) rotary systems in severely and abruptly curved root canals using cone beam computed tomography (CBCT) and ImageJ software.</div></div><div><h3>Materials and Methods</h3><div>Forty-eight mesial root canals of the mandibular first molars were assigned equally to three groups: PTN, WOG, and XPRS. Using ImageJ software, CBCT images were acquired pre- and post-instrumentation to assess dentin removal, remaining dentin thickness (RDT), canal transportation, and centering ratio at the coronal, middle, and apical levels. Statistical analyses were conducted on all numerical data.</div></div><div><h3>Results</h3><div>All rotary systems removed significantly more distocoronal dentin in the danger zone (DZ), than the mesiocoronal area. PTN removed significantly more dentin and caused less RDT than XPRS (p &lt; 0.05). However, there were no significant differences between PTN-WOG and WOG-XPRS. In the DZ, the highest percentage of specimens with an RDT &lt; 0.5 mm was observed when using PTN (50%), followed by WOG (31.3%), and XPRS (6.3%). Compared with PTN and WOG, XPRS demonstrated less coronal transportation. Among all rotary systems, there was no significant difference in apical transportation or centering ratio.</div></div><div><h3>Conclusions</h3><div>Based on our observations, all rotary instruments exhibited a tendency to remove dentin in the DZ, but to different degrees. XPRS demonstrated better results in terms of coronal transportation and dentin thickness in the DZ. Comparable centering abilities and minimal apical transportation were demonstrated using all rotary instruments.</div></div>\",\"PeriodicalId\":47246,\"journal\":{\"name\":\"Saudi Dental Journal\",\"volume\":\"36 10\",\"pages\":\"Pages 1333-1338\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Dental Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1013905224002128\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1013905224002128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景在选择根管预备器械时,必须考虑影响成形效率的几个参数,包括器械设计、冶金和操作运动。本研究旨在使用锥形束计算机断层扫描 (CBCT) 和 ImageJ 软件评估 ProTaper Next (PTN)、WaveOne Gold (WOG) 和 XP-endo Rise Shaper (XPRS) 旋转系统在严重和突然弯曲的根管中的塑形能力:PTN组、WOG组和XPRS组。使用 ImageJ 软件获取器械前后的 CBCT 图像,以评估牙本质去除、剩余牙本质厚度 (RDT)、根管运输以及冠状、中间和根尖水平的居中比率。所有旋转系统在危险区(DZ)去除的远端牙本质都明显多于中端区域。与 XPRS 相比,PTN 切除的牙本质明显更多,造成的 RDT 也更少(p < 0.05)。但是,PTN-WOG 和 WOG-XPRS 之间没有明显差异。在 DZ 中,使用 PTN 时观察到的 RDT < 0.5 mm 标本比例最高(50%),其次是 WOG(31.3%)和 XPRS(6.3%)。与 PTN 和 WOG 相比,XPRS 的冠状位移较少。结论根据我们的观察,所有的旋转器械都有去除DZ内牙本质的倾向,但程度不同。XPRS 在 DZ 的冠状迁移和牙本质厚度方面表现出更好的效果。所有的旋转器械都表现出了相似的定心能力和最小的根尖移位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the shaping ability of different rotary file systems in severely and abruptly curved root canals using cone beam computed tomography

Background

When selecting an instrument for canal preparation, it is important to consider several parameters that influence the shaping efficiency, including instrument design, metallurgy, and operating motion. This study aimed to evaluate the shaping ability of the ProTaper Next (PTN), WaveOne Gold (WOG), and XP-endo Rise Shaper (XPRS) rotary systems in severely and abruptly curved root canals using cone beam computed tomography (CBCT) and ImageJ software.

Materials and Methods

Forty-eight mesial root canals of the mandibular first molars were assigned equally to three groups: PTN, WOG, and XPRS. Using ImageJ software, CBCT images were acquired pre- and post-instrumentation to assess dentin removal, remaining dentin thickness (RDT), canal transportation, and centering ratio at the coronal, middle, and apical levels. Statistical analyses were conducted on all numerical data.

Results

All rotary systems removed significantly more distocoronal dentin in the danger zone (DZ), than the mesiocoronal area. PTN removed significantly more dentin and caused less RDT than XPRS (p < 0.05). However, there were no significant differences between PTN-WOG and WOG-XPRS. In the DZ, the highest percentage of specimens with an RDT < 0.5 mm was observed when using PTN (50%), followed by WOG (31.3%), and XPRS (6.3%). Compared with PTN and WOG, XPRS demonstrated less coronal transportation. Among all rotary systems, there was no significant difference in apical transportation or centering ratio.

Conclusions

Based on our observations, all rotary instruments exhibited a tendency to remove dentin in the DZ, but to different degrees. XPRS demonstrated better results in terms of coronal transportation and dentin thickness in the DZ. Comparable centering abilities and minimal apical transportation were demonstrated using all rotary instruments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Saudi Dental Journal
Saudi Dental Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.60
自引率
0.00%
发文量
86
审稿时长
22 weeks
期刊介绍: Saudi Dental Journal is an English language, peer-reviewed scholarly publication in the area of dentistry. Saudi Dental Journal publishes original research and reviews on, but not limited to: • dental disease • clinical trials • dental equipment • new and experimental techniques • epidemiology and oral health • restorative dentistry • periodontology • endodontology • prosthodontics • paediatric dentistry • orthodontics and dental education Saudi Dental Journal is the official publication of the Saudi Dental Society and is published by King Saud University in collaboration with Elsevier and is edited by an international group of eminent researchers.
期刊最新文献
Editorial Board Assessing the quality of AI information from ChatGPT regarding oral surgery, preventive dentistry, and oral cancer: An exploration study An in vitro study of fluoride-preloaded halloysite nanotubes to enhance the fluoride release in conventional and resin-modified glass ionomer cements Association between dental diseases and stroke Drug delivery systems in periodontitis: A visualization and bibliometric analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1