利用巨型磁阻生物传感器检测 Xa 因子活性

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL Analytica Chimica Acta Pub Date : 2024-10-16 DOI:10.1016/j.aca.2024.343347
Yulhwa Lee , Songeun Kim , Tae-Jin Song , Shan X. Wang , Jung-Rok Lee
{"title":"利用巨型磁阻生物传感器检测 Xa 因子活性","authors":"Yulhwa Lee ,&nbsp;Songeun Kim ,&nbsp;Tae-Jin Song ,&nbsp;Shan X. Wang ,&nbsp;Jung-Rok Lee","doi":"10.1016/j.aca.2024.343347","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>As anticoagulants are widely used to treat patients with atrial fibrillation (AF) and other thrombotic conditions, it is necessary for physicians to determine whether the medication has been taken in emergencies. Among many anticoagulants, rivaroxaban has attracted attention due to its safety and convenience. Since rivaroxaban inhibits activated coagulation factor X (factor Xa), measuring factor Xa activity can determine the presence of rivaroxaban.</div></div><div><h3>Results</h3><div>We report a magnetic biosensing platform capable of measuring the activity of factor Xa using peptide substrates conjugated with magnetic nanoparticles (MNPs). Due to the size of factor Xa, a new method of solution-phase assays was proposed for magnetic biosensing platforms to address issues with immobilized peptides on the sensors. This method was validated with factor Xa and trypsin, both of which are serine proteases. In the solution-phase assays, samples with either the enzymes of interest or no enzyme were simultaneously measured, and the activity of the enzyme was estimated using the difference between the measurements. Unlike conventional optical methods, our platform was capable of detecting the activity of factor Xa at 2 μg mL<sup>−1</sup> with a 30 min sample incubation.</div></div><div><h3>Significance</h3><div>The assay using giant magnetoresistive biosensors outperformed conventional optical techniques. This platform can facilitate the determination of the presence of rivaroxaban and assist physicians in deciding on appropriate treatments for patients.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1331 ","pages":"Article 343347"},"PeriodicalIF":5.7000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detection of factor Xa activity using giant magnetoresistive biosensors\",\"authors\":\"Yulhwa Lee ,&nbsp;Songeun Kim ,&nbsp;Tae-Jin Song ,&nbsp;Shan X. Wang ,&nbsp;Jung-Rok Lee\",\"doi\":\"10.1016/j.aca.2024.343347\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>As anticoagulants are widely used to treat patients with atrial fibrillation (AF) and other thrombotic conditions, it is necessary for physicians to determine whether the medication has been taken in emergencies. Among many anticoagulants, rivaroxaban has attracted attention due to its safety and convenience. Since rivaroxaban inhibits activated coagulation factor X (factor Xa), measuring factor Xa activity can determine the presence of rivaroxaban.</div></div><div><h3>Results</h3><div>We report a magnetic biosensing platform capable of measuring the activity of factor Xa using peptide substrates conjugated with magnetic nanoparticles (MNPs). Due to the size of factor Xa, a new method of solution-phase assays was proposed for magnetic biosensing platforms to address issues with immobilized peptides on the sensors. This method was validated with factor Xa and trypsin, both of which are serine proteases. In the solution-phase assays, samples with either the enzymes of interest or no enzyme were simultaneously measured, and the activity of the enzyme was estimated using the difference between the measurements. Unlike conventional optical methods, our platform was capable of detecting the activity of factor Xa at 2 μg mL<sup>−1</sup> with a 30 min sample incubation.</div></div><div><h3>Significance</h3><div>The assay using giant magnetoresistive biosensors outperformed conventional optical techniques. This platform can facilitate the determination of the presence of rivaroxaban and assist physicians in deciding on appropriate treatments for patients.</div></div>\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":\"1331 \",\"pages\":\"Article 343347\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003267024011486\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267024011486","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景由于抗凝药物被广泛用于治疗心房颤动(房颤)和其他血栓性疾病患者,因此医生有必要确定患者是否在紧急情况下服用了药物。在众多抗凝药物中,利伐沙班因其安全性和便利性而备受关注。由于利伐沙班抑制活化的凝血因子 X(Xa 因子),因此测量 Xa 因子的活性可以确定是否服用了利伐沙班。结果我们报告了一种磁性生物传感平台,该平台能够利用与磁性纳米粒子(MNPs)共轭的多肽底物测量 Xa 因子的活性。由于因子 Xa 的大小,我们为磁性生物传感平台提出了一种溶液相检测的新方法,以解决传感器上固定肽的问题。该方法通过 Xa 因子和胰蛋白酶进行了验证,这两种酶都是丝氨酸蛋白酶。在溶液相分析中,同时测量含有相关酶或不含酶的样品,并利用测量值之差估算酶的活性。与传统的光学方法不同,我们的平台能够检测 2 μg mL-1 的 Xa 因子活性,样品孵育时间为 30 分钟。该平台有助于确定利伐沙班的存在,并帮助医生决定对患者的适当治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detection of factor Xa activity using giant magnetoresistive biosensors

Background

As anticoagulants are widely used to treat patients with atrial fibrillation (AF) and other thrombotic conditions, it is necessary for physicians to determine whether the medication has been taken in emergencies. Among many anticoagulants, rivaroxaban has attracted attention due to its safety and convenience. Since rivaroxaban inhibits activated coagulation factor X (factor Xa), measuring factor Xa activity can determine the presence of rivaroxaban.

Results

We report a magnetic biosensing platform capable of measuring the activity of factor Xa using peptide substrates conjugated with magnetic nanoparticles (MNPs). Due to the size of factor Xa, a new method of solution-phase assays was proposed for magnetic biosensing platforms to address issues with immobilized peptides on the sensors. This method was validated with factor Xa and trypsin, both of which are serine proteases. In the solution-phase assays, samples with either the enzymes of interest or no enzyme were simultaneously measured, and the activity of the enzyme was estimated using the difference between the measurements. Unlike conventional optical methods, our platform was capable of detecting the activity of factor Xa at 2 μg mL−1 with a 30 min sample incubation.

Significance

The assay using giant magnetoresistive biosensors outperformed conventional optical techniques. This platform can facilitate the determination of the presence of rivaroxaban and assist physicians in deciding on appropriate treatments for patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
期刊最新文献
Development of a new spectral database of photo-induced pesticide compounds for an automatic monitoring and identification system. Glutathione-Functionalized Covalent Organic Frameworks@Silica as A Hydrophilic-Hydrophobic Balanced Mixed-Mode Stationary Phase for Highly Efficient Separation of Compounds with A Wide Range of Polarity Development of a portable SERS tool to evaluate the effectiveness of washing methods to remove pesticide residue from fruit surface Therapeutic Drug Monitoring of Methotrexate by Disposable SPCE Biosensor for Personalized Medicine Nanozymes Featuring a Mesoporous Silica Shell for Rapid Enrichment and Ultrasensitive Lateral Flow Immunoassay of Influenza A
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1