{"title":"泡沫填充夹芯板中埋设空气实体的空气耦合 Lamb 波测试","authors":"Christoph Haugwitz;Andre Reinartz;Jan-Helge Dörsam;Sonja Wismath;Gianni Allevato;Jan Hinrichs;Paulina Gorol;Annalena Kühn;Thomas Hahn-Jose;Jörg Lange;Mario Kupnik","doi":"10.1109/OJUFFC.2024.3410169","DOIUrl":null,"url":null,"abstract":"Sandwich panels, composed of two steel faces and a rigid foam core, are an inexpensive and lightweight option for construction industry. However, voids can form in the foam core during the manufacturing process. This paper uses ultrasonic testing to detect such voids in the foam core of sandwich panels, buried a few millimeters below the surface. The testing setup employs both air-coupled and non-contact ultrasonic testing. Different frequencies are investigated for their influence on the detection capabilities. Two air-coupled experimental setups are constructed, one at 40kHz and the other one at 200kHz. Artificial defects are carved into the sandwich panel at different depths. The results are compared to a simulation. We found that detecting buried voids in these sandwich panels is feasible. The 40-kHz setup has a larger penetration depth of 14mm, while the 200-kHz setup has a smaller penetration depth of 2.5mm. The 200-kHz setup shows a better contrast, i.e. the amplitude at the defect increases by 27% compared to 6% with the 40-kHz setup. These methods enable air-coupled, non-contact ultrasonic testing of buried defects in sandwich panels. They have the potential to be integrated into production lines, contributing to improved material efficiency and quality control for these sandwich panels.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"4 ","pages":"150-159"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10549941","citationCount":"0","resultStr":"{\"title\":\"Air-Coupled Lamb Wave Testing of Buried Air-Voids in Foam-Filled Sandwich Panels\",\"authors\":\"Christoph Haugwitz;Andre Reinartz;Jan-Helge Dörsam;Sonja Wismath;Gianni Allevato;Jan Hinrichs;Paulina Gorol;Annalena Kühn;Thomas Hahn-Jose;Jörg Lange;Mario Kupnik\",\"doi\":\"10.1109/OJUFFC.2024.3410169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sandwich panels, composed of two steel faces and a rigid foam core, are an inexpensive and lightweight option for construction industry. However, voids can form in the foam core during the manufacturing process. This paper uses ultrasonic testing to detect such voids in the foam core of sandwich panels, buried a few millimeters below the surface. The testing setup employs both air-coupled and non-contact ultrasonic testing. Different frequencies are investigated for their influence on the detection capabilities. Two air-coupled experimental setups are constructed, one at 40kHz and the other one at 200kHz. Artificial defects are carved into the sandwich panel at different depths. The results are compared to a simulation. We found that detecting buried voids in these sandwich panels is feasible. The 40-kHz setup has a larger penetration depth of 14mm, while the 200-kHz setup has a smaller penetration depth of 2.5mm. The 200-kHz setup shows a better contrast, i.e. the amplitude at the defect increases by 27% compared to 6% with the 40-kHz setup. These methods enable air-coupled, non-contact ultrasonic testing of buried defects in sandwich panels. They have the potential to be integrated into production lines, contributing to improved material efficiency and quality control for these sandwich panels.\",\"PeriodicalId\":73301,\"journal\":{\"name\":\"IEEE open journal of ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"4 \",\"pages\":\"150-159\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10549941\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE open journal of ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10549941/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10549941/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

夹芯板由两个钢面和一个硬质泡沫芯材组成,是建筑业中一种廉价而轻质的选择。然而,在生产过程中,泡沫夹芯中可能会形成空隙。本文利用超声波测试来检测夹芯板泡沫夹芯中埋藏在表面下几毫米处的空隙。测试装置采用了空气耦合和非接触式超声波测试。研究了不同频率对检测能力的影响。构建了两个空气耦合实验装置,一个频率为 40kHz,另一个频率为 200kHz。在夹芯板上雕刻不同深度的人造缺陷。实验结果与模拟结果进行了比较。我们发现,在这些夹芯板中检测埋藏的空隙是可行的。40 千赫设置的穿透深度较大,为 14 毫米,而 200 千赫设置的穿透深度较小,为 2.5 毫米。200 千赫设置显示出更好的对比度,即缺陷处的振幅增加了 27%,而 40 千赫设置仅增加了 6%。这些方法能够对夹芯板中的埋藏缺陷进行空气耦合、非接触超声波测试。它们有可能被集成到生产线中,有助于提高材料效率和这些夹芯板的质量控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Air-Coupled Lamb Wave Testing of Buried Air-Voids in Foam-Filled Sandwich Panels
Sandwich panels, composed of two steel faces and a rigid foam core, are an inexpensive and lightweight option for construction industry. However, voids can form in the foam core during the manufacturing process. This paper uses ultrasonic testing to detect such voids in the foam core of sandwich panels, buried a few millimeters below the surface. The testing setup employs both air-coupled and non-contact ultrasonic testing. Different frequencies are investigated for their influence on the detection capabilities. Two air-coupled experimental setups are constructed, one at 40kHz and the other one at 200kHz. Artificial defects are carved into the sandwich panel at different depths. The results are compared to a simulation. We found that detecting buried voids in these sandwich panels is feasible. The 40-kHz setup has a larger penetration depth of 14mm, while the 200-kHz setup has a smaller penetration depth of 2.5mm. The 200-kHz setup shows a better contrast, i.e. the amplitude at the defect increases by 27% compared to 6% with the 40-kHz setup. These methods enable air-coupled, non-contact ultrasonic testing of buried defects in sandwich panels. They have the potential to be integrated into production lines, contributing to improved material efficiency and quality control for these sandwich panels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array The 3D Estimation of Mechanical Wave Velocities in the Heart: Methods and Insights Direct Digital Simultaneous Phase-Amplitude Noise and Allan Deviation Measurement System Rochelle Salt Revisited for Eco-Designed Ultrasonic Transducers 3-D Object Reconstruction From Outdoor Ultrasonic Image and Variation Autoencoder
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1