{"title":"表面声波平台与紫外线激活的 rGO-SnS2 纳米复合材料集成,实现室温下 ppb 级甲基膦酸二甲酯检测。","authors":"Jinbo Zhang, Jian Zhou, Hui Chen, Yihao Guo, Qikun Tian, Yanhong Xia, Guangzhao Qin, Jianfei Xie, Yongqing Fu","doi":"10.1016/j.talanta.2024.127063","DOIUrl":null,"url":null,"abstract":"<p><p>Dimethyl methylphosphonate (DMMP) is commonly used as an alternative for demonstrating to detect sarin, which is one of the most toxic but odorless chemical nerve agents. Among various types of DMMP sensors, those utilizing surface acoustic wave (SAW) technology provide notable advantages such as wireless/passive monitoring, digital output, and a compact, portable design. However, key challenges for SAW-based DMMP sensors operated at room temperature lies in simultaneous enhancement of sensitivities and reduction of detection limits. In this study, we developed a binary material strategy by combining reduced graphene oxide (rGO) and tin disulfide (SnS<sub>2</sub>) with (100)-facets orientation as sensing layers of SAW device for DMMP detection utilized at room temperature. Ultraviolet (UV) light was applied to activate the sensitive film and reduce the sensor's response time. The developed SAW DMMP sensor demonstrated a superior sensitivity (-1298.82 Hz/ppm), a low detection limit of 50 ppb, and a hysteresis below 1.5%, along with fast response/recovery time (39.2 s/28.4 s), excellent selectivity, long-term stability and repeatability. The formation of shrub-like rGO-SnS<sub>2</sub> heterojunctions with abundant surface defects and large specific surface areas, high-energy (100) crystalline surfaces of SnS<sub>2</sub>, and photogenerated carriers generated by UV irradiation were pinpointed as the crucial sensing mechanisms. These factors collectively enhanced adsorption and reaction dynamics of DMMP molecules.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"282 ","pages":"127063"},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surface acoustic wave platform integrated with ultraviolet activated rGO-SnS<sub>2</sub> nanocomposites to achieve ppb-level dimethyl methylphosphonate detection at room-temperature.\",\"authors\":\"Jinbo Zhang, Jian Zhou, Hui Chen, Yihao Guo, Qikun Tian, Yanhong Xia, Guangzhao Qin, Jianfei Xie, Yongqing Fu\",\"doi\":\"10.1016/j.talanta.2024.127063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Dimethyl methylphosphonate (DMMP) is commonly used as an alternative for demonstrating to detect sarin, which is one of the most toxic but odorless chemical nerve agents. Among various types of DMMP sensors, those utilizing surface acoustic wave (SAW) technology provide notable advantages such as wireless/passive monitoring, digital output, and a compact, portable design. However, key challenges for SAW-based DMMP sensors operated at room temperature lies in simultaneous enhancement of sensitivities and reduction of detection limits. In this study, we developed a binary material strategy by combining reduced graphene oxide (rGO) and tin disulfide (SnS<sub>2</sub>) with (100)-facets orientation as sensing layers of SAW device for DMMP detection utilized at room temperature. Ultraviolet (UV) light was applied to activate the sensitive film and reduce the sensor's response time. The developed SAW DMMP sensor demonstrated a superior sensitivity (-1298.82 Hz/ppm), a low detection limit of 50 ppb, and a hysteresis below 1.5%, along with fast response/recovery time (39.2 s/28.4 s), excellent selectivity, long-term stability and repeatability. The formation of shrub-like rGO-SnS<sub>2</sub> heterojunctions with abundant surface defects and large specific surface areas, high-energy (100) crystalline surfaces of SnS<sub>2</sub>, and photogenerated carriers generated by UV irradiation were pinpointed as the crucial sensing mechanisms. These factors collectively enhanced adsorption and reaction dynamics of DMMP molecules.</p>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"282 \",\"pages\":\"127063\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.talanta.2024.127063\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127063","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Surface acoustic wave platform integrated with ultraviolet activated rGO-SnS2 nanocomposites to achieve ppb-level dimethyl methylphosphonate detection at room-temperature.
Dimethyl methylphosphonate (DMMP) is commonly used as an alternative for demonstrating to detect sarin, which is one of the most toxic but odorless chemical nerve agents. Among various types of DMMP sensors, those utilizing surface acoustic wave (SAW) technology provide notable advantages such as wireless/passive monitoring, digital output, and a compact, portable design. However, key challenges for SAW-based DMMP sensors operated at room temperature lies in simultaneous enhancement of sensitivities and reduction of detection limits. In this study, we developed a binary material strategy by combining reduced graphene oxide (rGO) and tin disulfide (SnS2) with (100)-facets orientation as sensing layers of SAW device for DMMP detection utilized at room temperature. Ultraviolet (UV) light was applied to activate the sensitive film and reduce the sensor's response time. The developed SAW DMMP sensor demonstrated a superior sensitivity (-1298.82 Hz/ppm), a low detection limit of 50 ppb, and a hysteresis below 1.5%, along with fast response/recovery time (39.2 s/28.4 s), excellent selectivity, long-term stability and repeatability. The formation of shrub-like rGO-SnS2 heterojunctions with abundant surface defects and large specific surface areas, high-energy (100) crystalline surfaces of SnS2, and photogenerated carriers generated by UV irradiation were pinpointed as the crucial sensing mechanisms. These factors collectively enhanced adsorption and reaction dynamics of DMMP molecules.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.