{"title":"在不同的多尔类型中,合体填充式和锥形楔形阀杆的腿长差异风险不同。","authors":"Yueh-Ting Hung, Cheng-Yang Chang, Kun-Han Lee, Wei-Lin Chang, Shang-Wen Tsai, Cheng-Fong Chen, Po-Kuei Wu, Wei-Ming Chen","doi":"10.1007/s00402-024-05563-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs.</p><p><strong>Materials and methods: </strong>From April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures. We categorized all procedures into three groups: Dorr type A (N = 220, 18.7%), B (N = 875, 74.3%), and C (N = 83, 7.0%). Within each Dorr type, we compared the incidence and risk of postoperative LLD ≥ 10 mm between the two stem types. The factors considered in the multivariate regression analyses included stem type, age, sex, body mass index, diagnosis, canal flare index, femoral cortical index and stem alignment.</p><p><strong>Results: </strong>The taper wedge stem group had a higher overall incidence of LLD ≥ 10 mm (12.8% vs. 7.4%, P = 0.012) and in Dorr type A femurs (22.2% vs. 7.6%, P = 0.014), compared with the fit-and-fill stem group. In multivariate analysis, the taper wedge stem exhibited an increased risk of LLD ≥ 10 mm only in Dorr type A femurs (aOR: 3.449, 95% CI: 1.325-8.794). The incidence and risk of LLD ≥ 10 mm were not different between the two stems in Dorr type B and C femurs.</p><p><strong>Conclusions: </strong>The taper wedge stem demonstrated an elevated risk of LLD ≥ 10 mm in Dorr type A femurs compared with the fit-and-fill stem, necessitating meticulous preoperative templating and intraoperative femoral canal preparation.</p>","PeriodicalId":8326,"journal":{"name":"Archives of Orthopaedic and Trauma Surgery","volume":" ","pages":"4783-4789"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Leg length discrepancy risk differs between fit-and-fill and taper wedge stems across Dorr types.\",\"authors\":\"Yueh-Ting Hung, Cheng-Yang Chang, Kun-Han Lee, Wei-Lin Chang, Shang-Wen Tsai, Cheng-Fong Chen, Po-Kuei Wu, Wei-Ming Chen\",\"doi\":\"10.1007/s00402-024-05563-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs.</p><p><strong>Materials and methods: </strong>From April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures. We categorized all procedures into three groups: Dorr type A (N = 220, 18.7%), B (N = 875, 74.3%), and C (N = 83, 7.0%). Within each Dorr type, we compared the incidence and risk of postoperative LLD ≥ 10 mm between the two stem types. The factors considered in the multivariate regression analyses included stem type, age, sex, body mass index, diagnosis, canal flare index, femoral cortical index and stem alignment.</p><p><strong>Results: </strong>The taper wedge stem group had a higher overall incidence of LLD ≥ 10 mm (12.8% vs. 7.4%, P = 0.012) and in Dorr type A femurs (22.2% vs. 7.6%, P = 0.014), compared with the fit-and-fill stem group. In multivariate analysis, the taper wedge stem exhibited an increased risk of LLD ≥ 10 mm only in Dorr type A femurs (aOR: 3.449, 95% CI: 1.325-8.794). The incidence and risk of LLD ≥ 10 mm were not different between the two stems in Dorr type B and C femurs.</p><p><strong>Conclusions: </strong>The taper wedge stem demonstrated an elevated risk of LLD ≥ 10 mm in Dorr type A femurs compared with the fit-and-fill stem, necessitating meticulous preoperative templating and intraoperative femoral canal preparation.</p>\",\"PeriodicalId\":8326,\"journal\":{\"name\":\"Archives of Orthopaedic and Trauma Surgery\",\"volume\":\" \",\"pages\":\"4783-4789\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Orthopaedic and Trauma Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00402-024-05563-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Orthopaedic and Trauma Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00402-024-05563-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
简介:在全髋关节置换术(THA)中,对不同股骨近端形态类型的无骨水泥锥形楔形柄和拟合填充柄的比较尚未进行全面评估。本研究旨在比较这两种股骨柄类型在Dorr A、B和C型股骨中腿长差异(LLD)≥10 mm的风险:从2015年4月到2021年4月,我们分析了1178例单侧初级无骨水泥THA手术。我们将所有手术分为三组:Dorr A 型(N = 220,18.7%)、B 型(N = 875,74.3%)和 C 型(N = 83,7.0%)。在每种Dorr类型中,我们比较了两种骨干类型术后LLD≥10 mm的发生率和风险。多变量回归分析考虑的因素包括骨干类型、年龄、性别、体重指数、诊断、骨管扩张指数、股骨皮质指数和骨干排列:锥形楔形柄组的LLD≥10毫米(12.8% vs. 7.4%,P = 0.012)和Dorr A型股骨的LLD≥10毫米(22.2% vs. 7.6%,P = 0.014)的总体发生率高于配合填充柄组。在多变量分析中,锥形楔形柄仅在Dorr A型股骨中显示LLD ≥ 10 mm的风险增加(aOR:3.449,95% CI:1.325-8.794)。在Dorr B型和C型股骨中,两种柄的LLD≥10 mm的发生率和风险没有差异:锥形楔形股骨柄在Dorr A型股骨中发生LLD≥10 mm的风险高于贴合填充式股骨柄,因此必须进行细致的术前模板设计和术中股骨管道准备。
Leg length discrepancy risk differs between fit-and-fill and taper wedge stems across Dorr types.
Introduction: The comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs.
Materials and methods: From April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures. We categorized all procedures into three groups: Dorr type A (N = 220, 18.7%), B (N = 875, 74.3%), and C (N = 83, 7.0%). Within each Dorr type, we compared the incidence and risk of postoperative LLD ≥ 10 mm between the two stem types. The factors considered in the multivariate regression analyses included stem type, age, sex, body mass index, diagnosis, canal flare index, femoral cortical index and stem alignment.
Results: The taper wedge stem group had a higher overall incidence of LLD ≥ 10 mm (12.8% vs. 7.4%, P = 0.012) and in Dorr type A femurs (22.2% vs. 7.6%, P = 0.014), compared with the fit-and-fill stem group. In multivariate analysis, the taper wedge stem exhibited an increased risk of LLD ≥ 10 mm only in Dorr type A femurs (aOR: 3.449, 95% CI: 1.325-8.794). The incidence and risk of LLD ≥ 10 mm were not different between the two stems in Dorr type B and C femurs.
Conclusions: The taper wedge stem demonstrated an elevated risk of LLD ≥ 10 mm in Dorr type A femurs compared with the fit-and-fill stem, necessitating meticulous preoperative templating and intraoperative femoral canal preparation.
期刊介绍:
"Archives of Orthopaedic and Trauma Surgery" is a rich source of instruction and information for physicians in clinical practice and research in the extensive field of orthopaedics and traumatology. The journal publishes papers that deal with diseases and injuries of the musculoskeletal system from all fields and aspects of medicine. The journal is particularly interested in papers that satisfy the information needs of orthopaedic clinicians and practitioners. The journal places special emphasis on clinical relevance.
"Archives of Orthopaedic and Trauma Surgery" is the official journal of the German Speaking Arthroscopy Association (AGA).