玻璃浸润和改良冷却速度对单色和多层高氧化钇氧化锆颜色特征变化的影响。

Pithiwat Uasuwan, Niwut Juntavee, Apa Juntavee
{"title":"玻璃浸润和改良冷却速度对单色和多层高氧化钇氧化锆颜色特征变化的影响。","authors":"Pithiwat Uasuwan, Niwut Juntavee, Apa Juntavee","doi":"10.4317/jced.62066","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Sintering technique impacted color of zirconia. This study examined the effect of glass infiltration and altering cooling rate on color alteration of monochrome (Mo) and multilayer (Mu) 5 mol% yttria-partially stabilized zirconia (5Y-PSZ).</p><p><strong>Material and methods: </strong>180 specimens (width, length, thickness = 10, 20, 2 mm) were prepared from Mo and Mu (comprising cervical (C) and incisal (I) zone) 5Y-PSZ shade VITA-A2. Unintentionally categorized samples (n=15/group) were sintered with traditional (T) versus glass infiltrated (G) technique and cooled down with slow (S: 5°C/min), normal (N: 35°C/min), and fast (F: 70°C/min). CIE-L*a*b* color characteristics were determined for translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP), and color difference (∆Ediff). Microstructures were investigated with SEM and XRD. ANOVA and Tamhane's comparisons were determined for significant differences (<i>p</i><0.05).</p><p><strong>Results: </strong>TP and OP were significantly higher for Mo than MuC and MuI, but no significant difference in CR among them. Comparable ΔEdiff between Mo and MuC were indicated, but both were significantly lesser than MuL. Glass infiltration and raising cooling rate significantly decreased TP and OP, whereas increased CR and ΔEdiff, which amplified color alteration.</p><p><strong>Conclusions: </strong>Glass infiltration sintering and modified cooling rate significantly altered color parameters of 5Y-PSZ. Monochrome demonstrated higher translucency and opalescence than multilayer, possibly due to colorant additives. Glass infiltration decreased translucency and opalescence due to different refractive indices. Increased cooling rate resulted in decreasing translucency and opalescence due to smaller grain size and t→m transformation. Nevertheless, altered sintering and cooling rates still rendered an acceptable color alteration. <b>Key words:</b>Cooling rate, glass infiltration, optical characteristics, translucency.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 9","pages":"e1079-e1091"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11470454/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of glass infiltration and modified cooling rates on color characteristics alteration of monochrome and multilayer high yttrium oxide containing zirconia.\",\"authors\":\"Pithiwat Uasuwan, Niwut Juntavee, Apa Juntavee\",\"doi\":\"10.4317/jced.62066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Sintering technique impacted color of zirconia. This study examined the effect of glass infiltration and altering cooling rate on color alteration of monochrome (Mo) and multilayer (Mu) 5 mol% yttria-partially stabilized zirconia (5Y-PSZ).</p><p><strong>Material and methods: </strong>180 specimens (width, length, thickness = 10, 20, 2 mm) were prepared from Mo and Mu (comprising cervical (C) and incisal (I) zone) 5Y-PSZ shade VITA-A2. Unintentionally categorized samples (n=15/group) were sintered with traditional (T) versus glass infiltrated (G) technique and cooled down with slow (S: 5°C/min), normal (N: 35°C/min), and fast (F: 70°C/min). CIE-L*a*b* color characteristics were determined for translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP), and color difference (∆Ediff). Microstructures were investigated with SEM and XRD. ANOVA and Tamhane's comparisons were determined for significant differences (<i>p</i><0.05).</p><p><strong>Results: </strong>TP and OP were significantly higher for Mo than MuC and MuI, but no significant difference in CR among them. Comparable ΔEdiff between Mo and MuC were indicated, but both were significantly lesser than MuL. Glass infiltration and raising cooling rate significantly decreased TP and OP, whereas increased CR and ΔEdiff, which amplified color alteration.</p><p><strong>Conclusions: </strong>Glass infiltration sintering and modified cooling rate significantly altered color parameters of 5Y-PSZ. Monochrome demonstrated higher translucency and opalescence than multilayer, possibly due to colorant additives. Glass infiltration decreased translucency and opalescence due to different refractive indices. Increased cooling rate resulted in decreasing translucency and opalescence due to smaller grain size and t→m transformation. Nevertheless, altered sintering and cooling rates still rendered an acceptable color alteration. <b>Key words:</b>Cooling rate, glass infiltration, optical characteristics, translucency.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"16 9\",\"pages\":\"e1079-e1091\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11470454/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.62066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.62066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:烧结技术会影响氧化锆的颜色。本研究考察了玻璃渗透和改变冷却速度对单色(Mo)和多层(Mu)5 mol%钇局部稳定氧化锆(5Y-PSZ)颜色改变的影响。材料和方法:从 Mo 和 Mu(包括颈(C)和切(I)区)5Y-PSZ VITA-A2 阴影中制备了 180 个试样(宽度、长度、厚度 = 10、20、2 毫米)。对无意分类的样品(n=15/组)分别采用传统(T)和玻璃渗入(G)技术进行烧结,并分别以慢速(S:5°C/分钟)、正常(N:35°C/分钟)和快速(F:70°C/分钟)进行冷却。测定了 CIE-L*a*b* 颜色特性,包括半透明参数 (TP)、对比度 (CR)、乳白参数 (OP) 和色差 (ΔEdiff)。用 SEM 和 XRD 对微观结构进行了研究。采用方差分析和 Tamhane 比较法确定显著差异(pResults:Mo 的 TP 和 OP 明显高于 MuC 和 MuI,但它们之间的 CR 没有明显差异。Mo 和 MuC 的 ΔEdiff 具有可比性,但都明显低于 MuL。玻璃渗入和提高冷却速度明显降低了 TP 和 OP,但增加了 CR 和 ΔEdiff,从而扩大了颜色变化:结论:玻璃渗入烧结和改变冷却速度会明显改变 5Y-PSZ 的颜色参数。与多层板相比,单色板显示出更高的半透明度和乳白度,这可能是由于着色剂添加剂所致。由于折射率不同,玻璃渗入会降低半透明度和乳白度。由于晶粒尺寸变小和 t→m 转变,增加冷却速度会导致半透明度和乳白度降低。尽管如此,改变烧结率和冷却率仍能带来可接受的颜色变化。关键词:冷却速率、玻璃浸润、光学特性、透光率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of glass infiltration and modified cooling rates on color characteristics alteration of monochrome and multilayer high yttrium oxide containing zirconia.

Background: Sintering technique impacted color of zirconia. This study examined the effect of glass infiltration and altering cooling rate on color alteration of monochrome (Mo) and multilayer (Mu) 5 mol% yttria-partially stabilized zirconia (5Y-PSZ).

Material and methods: 180 specimens (width, length, thickness = 10, 20, 2 mm) were prepared from Mo and Mu (comprising cervical (C) and incisal (I) zone) 5Y-PSZ shade VITA-A2. Unintentionally categorized samples (n=15/group) were sintered with traditional (T) versus glass infiltrated (G) technique and cooled down with slow (S: 5°C/min), normal (N: 35°C/min), and fast (F: 70°C/min). CIE-L*a*b* color characteristics were determined for translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP), and color difference (∆Ediff). Microstructures were investigated with SEM and XRD. ANOVA and Tamhane's comparisons were determined for significant differences (p<0.05).

Results: TP and OP were significantly higher for Mo than MuC and MuI, but no significant difference in CR among them. Comparable ΔEdiff between Mo and MuC were indicated, but both were significantly lesser than MuL. Glass infiltration and raising cooling rate significantly decreased TP and OP, whereas increased CR and ΔEdiff, which amplified color alteration.

Conclusions: Glass infiltration sintering and modified cooling rate significantly altered color parameters of 5Y-PSZ. Monochrome demonstrated higher translucency and opalescence than multilayer, possibly due to colorant additives. Glass infiltration decreased translucency and opalescence due to different refractive indices. Increased cooling rate resulted in decreasing translucency and opalescence due to smaller grain size and t→m transformation. Nevertheless, altered sintering and cooling rates still rendered an acceptable color alteration. Key words:Cooling rate, glass infiltration, optical characteristics, translucency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
期刊最新文献
Inverted ductal papilloma: report of a rare case and review of the literature. Nano-Hydroxyapatite toothpaste of rice field snail shell combined with basil leaf extract as a remineralizing and antibacterial agent to prevent dental caries. Optimizing pterygoid implant placement without sinus intrusion in edentulous vietnamese patients: A comprehensive tomographic analysis and cross-sectional study. Epidemiological and Radiomorphometric Aspects of the Accessory Mental Foramen in Brazilian Individuals: An Analysis by Cone Beam Computed Tomography. Evaluation of panoramic images in the assessment of mandibular second molar impaction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1